메뉴 건너뛰기




Volumn 9, Issue 1, 2015, Pages 56-73

Robust resting state fMRI processing for studies on typical brain development based on multi-echo EPI acquisition

Author keywords

Aging; BOLD; Coregistration; Denoising; Functional connectivity; ICA; PCA; Seed based; T2

Indexed keywords

ADOLESCENT; ADULT; ANTERIOR CINGULATE; ANTERIOR INSULA; ARTICLE; BOLD SIGNAL; BRAIN DEVELOPMENT; BRAIN FOURTH VENTRICLE; CEREBELLUM; CEREBROSPINAL FLUID; CHILD; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; DEFAULT MODE NETWORK; FEMALE; FREQUENCY MODULATION; FUNCTIONAL MAGNETIC RESONANCE IMAGING; FUNCTIONAL NEUROIMAGING; GRAY MATTER; HIPPOCAMPUS; HUMAN; HUMAN EXPERIMENT; MALE; MOTOR CORTEX; NOISE REDUCTION; NORMAL HUMAN; POSTERIOR CINGULATE; PRIORITY JOURNAL; RESTING STATE NETWORK; VENTROMEDIAL PREFRONTAL CORTEX; WHITE MATTER; YOUNG ADULT; AGE; BLOOD; BRAIN; COHORT ANALYSIS; CONNECTOME; GROWTH, DEVELOPMENT AND AGING; NUCLEAR MAGNETIC RESONANCE IMAGING; PROCEDURES; STATISTICAL ANALYSIS;

EID: 84925485661     PISSN: 19317557     EISSN: 19317565     Source Type: Journal    
DOI: 10.1007/s11682-014-9346-4     Document Type: Article
Times cited : (38)

References (43)
  • 1
    • 0028387214 scopus 로고
    • Spin - echo and gradientecho EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T
    • Bandettini, P.A., Wong, E.C., Jesmanowicz, A., Hinkst, R.S., Hyde, J.S. (1994). Spin - echo and gradientecho EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T. NMR in Biomedicine, 7(1–2), 12–20.
    • (1994) NMR in Biomedicine , vol.7 , Issue.1-2 , pp. 12-20
    • Bandettini, P.A.1    Wong, E.C.2    Jesmanowicz, A.3    Hinkst, R.S.4    Hyde, J.S.5
  • 2
    • 1342324773 scopus 로고    scopus 로고
    • Probabilistic independent component analysis for functional magnetic resonance imaging
    • PID: 1496456
    • Beckmann, C., & Smith, S. (2004). Probabilistic independent component analysis for functional magnetic resonance imaging. IEEE Transactions on Medical Imaging, 23(2), 137–152.
    • (2004) IEEE Transactions on Medical Imaging , vol.23 , Issue.2 , pp. 137-152
    • Beckmann, C.1    Smith, S.2
  • 3
    • 84883621994 scopus 로고    scopus 로고
    • Bold sensitivity and snr characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI
    • PID: 2395448
    • Bhavsar, S., Zvyagintsev, M., Mathiak, K. (2014). Bold sensitivity and snr characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI. NeuroImage, 84, 65–75.
    • (2014) NeuroImage , vol.84 , pp. 65-75
    • Bhavsar, S.1    Zvyagintsev, M.2    Mathiak, K.3
  • 4
    • 33746852686 scopus 로고    scopus 로고
    • Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI
    • PID: 1663237
    • Birn, R., Diamond, J., Smith, M., Bandettini, P. (2006). Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI. Neuroimage, 31 (4), 1536– 1548.
    • (2006) Neuroimage , vol.31 , Issue.4 , pp. 1536-1548
    • Birn, R.1    Diamond, J.2    Smith, M.3    Bandettini, P.4
  • 5
    • 0029166541 scopus 로고
    • Functional connectivity in the motor cortex of resting human brain using echo-planar MRI
    • Biswal, B., Yetkin, F., Haughton, V., Hyde, J. (1995). Functional connectivity in the motor cortex of resting human brain using echo-planar MRI. Magnetic Resonance in Medicine, 34(4), 537–541.
    • (1995) Magnetic Resonance in Medicine , vol.34 , Issue.4 , pp. 537-541
    • Biswal, B.1    Yetkin, F.2    Haughton, V.3    Hyde, J.4
  • 6
    • 84925516637 scopus 로고    scopus 로고
    • Boyacioglu, R. (2014). Improving sensitivity & specificity for rs fMRI using multiband multi-echo EPI. In Proceedings of the ISMRM, Abstract
    • Boyacioglu, R. (2014). Improving sensitivity & specificity for rs fMRI using multiband multi-echo EPI. In Proceedings of the ISMRM, Abstract.
  • 7
    • 84877072447 scopus 로고    scopus 로고
    • Optimizing the order of operations for movement scrubbing: Comment on power
    • Carp, J. (2013). Optimizing the order of operations for movement scrubbing: Comment on power et al. Neuroimage, 76, 436–438.
    • (2013) Neuroimage , vol.76 , pp. 436-438
    • Carp, J.1
  • 8
    • 33751108300 scopus 로고    scopus 로고
    • Classification of independent components using IC-fingerprints and support vector machine classifiers
    • De Martino, F., Gentile, F., Esposito, F., Balsi, M., Di Salle, F., Goebel, R., Formisano, E. (2007). Classification of independent components using IC-fingerprints and support vector machine classifiers. Neuroimage, 34(1), 177–194.
    • (2007) Neuroimage , vol.34 , Issue.1 , pp. 177-194
    • De Martino, F.1    Gentile, F.2    Esposito, F.3    Balsi, M.4    Di Salle, F.5    Goebel, R.6    Formisano, E.7
  • 10
    • 84910022208 scopus 로고    scopus 로고
    • Separating slow BOLD from non-BOLD baseline drifts using multi-echo fMRI
    • Evans, J.W., Kundu, P., Horovitz, S.G., Bandettini, P.A. (2015). Separating slow BOLD from non-BOLD baseline drifts using multi-echo fMRI. NeuroImage, 105, 189–197.
    • (2015) NeuroImage , vol.105 , pp. 189-197
    • Evans, J.W.1    Kundu, P.2    Horovitz, S.G.3    Bandettini, P.A.4
  • 11
    • 0038236731 scopus 로고    scopus 로고
    • Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging
    • Frayne, R., Goodyear, B.G., Dickhoff, P., Lauzon, M.L., Sevick, R.J. (2003). Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Investigative radiology, 38(7), 385–402.
    • (2003) Investigative radiology , vol.38 , Issue.7 , pp. 385-402
    • Frayne, R.1    Goodyear, B.G.2    Dickhoff, P.3    Lauzon, M.L.4    Sevick, R.J.5
  • 13
    • 0030044402 scopus 로고    scopus 로고
    • Decomposition of inflow and blood oxygen level dependent (BOLD) effects with dual echo spiral gradient recalled echo (GRE) fMRI
    • COI: 1:STN:280:DyaK283jsVygug%3D%3D, PID: 869994
    • Glover, G., Lemieux, S., Drangova, M., Pauly, J. (1996). Decomposition of inflow and blood oxygen level dependent (BOLD) effects with dual echo spiral gradient recalled echo (GRE) fMRI. Magnetic Resonance in Medicine, 35(3), 299–308.
    • (1996) Magnetic Resonance in Medicine , vol.35 , Issue.3 , pp. 299-308
    • Glover, G.1    Lemieux, S.2    Drangova, M.3    Pauly, J.4
  • 14
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out bold fmri for increased snr and reduced susceptibility artifacts
    • COI: 1:STN:280:DC%2BD3MrgtVKgsA%3D%3D, PID: 1155024
    • Glover, G.H., & Law, C.S. (2001). Spiral-in/out bold fmri for increased snr and reduced susceptibility artifacts. Magnetic Resonance in Medicine, 46(3), 515–522.
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.3 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2
  • 15
    • 34247502887 scopus 로고    scopus 로고
    • Theoretical optimization of multi-echo fMRI data acquisition
    • COI: 1:STN:280:DC%2BD2s7nsFGjtA%3D%3D, PID: 1737491
    • Gowland, P., & Bowtell, R. (2007). Theoretical optimization of multi-echo fMRI data acquisition. Physics in medicine and biology, 52, 1801.
    • (2007) Physics in medicine and biology , vol.52 , pp. 1801
    • Gowland, P.1    Bowtell, R.2
  • 19
    • 84945200962 scopus 로고    scopus 로고
    • Himberg, J., & Hyvarinen, A. (2003). Icasso: software for investigating the reliability of ica estimates by clustering and visualization. In 2003 IEEE 13th Workshop on Neural Networks for Signal Processing, 2003. NNSP’03, (pp. 259–268): IEEE
    • Himberg, J., & Hyvarinen, A. (2003). Icasso: software for investigating the reliability of ica estimates by clustering and visualization. In 2003 IEEE 13th Workshop on Neural Networks for Signal Processing, 2003. NNSP’03, (pp. 259–268): IEEE.
  • 20
    • 0042826822 scopus 로고    scopus 로고
    • Independent component analysis: algorithms and applications
    • Hyvrinen, & Oja, E. (2000). Independent component analysis: algorithms and applications. Neural networks, 13(4), 411–430.
    • (2000) Neural networks , vol.13 , Issue.4 , pp. 411-430
  • 21
    • 84886427729 scopus 로고    scopus 로고
    • An assessment of motion artefacts in multi band epi for high spatial and temporal resolution resting state fmri. In Proceedings of the ISMRM
    • Kelly, M.E., & Miller, K. (2013). An assessment of motion artefacts in multi band epi for high spatial and temporal resolution resting state fmri. In Proceedings of the ISMRM, Abstract, vol 3275.
    • (2013) Abstract, vol , pp. 3275
    • Kelly, M.E.1    Miller, K.2
  • 22
    • 84857738843 scopus 로고    scopus 로고
    • Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
    • Kundu, P., Inati, S.J., Evans, J.W., Luh W.M., Bandettini, P.A. (2012). Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI. NeuroImage, 60(3), 1759–1770.
    • (2012) NeuroImage , vol.60 , Issue.3 , pp. 1759-1770
    • Kundu, P.1    Inati, S.J.2    Evans, J.W.3    Luh, W.M.4    Bandettini, P.A.5
  • 24
    • 84986548209 scopus 로고    scopus 로고
    • Multi-echo simultaneous multi-slice fmri: Reliable high-dimensional decomposition and unbiased component classification. In Proceedings of the ISMRM
    • Kundu, P., Olafson, V., SJ, I., PA, B., TT, L. (2014). Multi-echo simultaneous multi-slice fmri: Reliable high-dimensional decomposition and unbiased component classification. In Proceedings of the ISMRM. Abstract, vol 2977.
    • (2014) Abstract, vol , pp. 2977
    • Kundu, P.1    Olafson, V.2    SJ, I.3    PA, B.4    TT, L.5
  • 25
    • 84907450916 scopus 로고    scopus 로고
    • Differentiating BOLD and non-BOLD signals in fMRI time series from anesthetized rats using multi-echo EPI at 11.7 T
    • Kundu, P., Santin, M.D., Bandettini, P.A., Bullmore, E.T., Petiet, A. (2014). Differentiating BOLD and non-BOLD signals in fMRI time series from anesthetized rats using multi-echo EPI at 11.7 T. NeuroImage, 102, 861–874.
    • (2014) NeuroImage , vol.102 , pp. 861-874
    • Kundu, P.1    Santin, M.D.2    Bandettini, P.A.3    Bullmore, E.T.4    Petiet, A.5
  • 26
    • 0026687990 scopus 로고
    • Age-related differences in volumes of subcortical nuclei, brain matter, and cerebrospinal fluid in healthy men as measured with magnetic resonance imaging
    • Murphy, D.G., DeCarli, C., Schapiro, M.B., Rapoport, S.I., Horwitz, B. (1992). Age-related differences in volumes of subcortical nuclei, brain matter, and cerebrospinal fluid in healthy men as measured with magnetic resonance imaging. Archives of Neurology, 49(8), 839–845.
    • (1992) Archives of Neurology , vol.49 , Issue.8 , pp. 839-845
    • Murphy, D.G.1    DeCarli, C.2    Schapiro, M.B.3    Rapoport, S.I.4    Horwitz, B.5
  • 27
    • 0036334757 scopus 로고    scopus 로고
    • An investigation of the value of spin-echo-based fMRI using a stroop color–word matching task and EPI at 3 T
    • Norris, D.G., Zysset, S., Mildner, T., Wiggins, C.J. (2002). An investigation of the value of spin-echo-based fMRI using a stroop color–word matching task and EPI at 3 T. Neuroimage, 15(3), 719–726.
    • (2002) Neuroimage , vol.15 , Issue.3 , pp. 719-726
    • Norris, D.G.1    Zysset, S.2    Mildner, T.3    Wiggins, C.J.4
  • 28
    • 0036667334 scopus 로고    scopus 로고
    • T(2)(*) dependence of low frequency functional connectivity
    • Peltier, S.J., & Noll, D.C. (2002). T(2)(*) dependence of low frequency functional connectivity. Neuroimage, 16, 985–992.
    • (2002) Neuroimage , vol.16 , pp. 985-992
    • Peltier, S.J.1    Noll, D.C.2
  • 29
    • 33744964361 scopus 로고    scopus 로고
    • BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: parallel acquired inhomogeneity desensitized fMRI
    • Poser, BA., Versluis, M.J., Hoogduin, J.M., Norris, D.G. (2006). BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: parallel acquired inhomogeneity desensitized fMRI. Magnetic Resonance in Medicine, 55(6), 1227–1235.
    • (2006) Magnetic Resonance in Medicine , vol.55 , Issue.6 , pp. 1227-1235
    • Poser, B.A.1    Versluis, M.J.2    Hoogduin, J.M.3    Norris, D.G.4
  • 31
    • 84855455705 scopus 로고    scopus 로고
    • Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion
    • Power, J.D., Barnes, K.A., Snyder, A.Z., Schlaggar, B.L., Petersen, S.E. (2011). Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion. Neuroimage, 59(3), 2142–2154.
    • (2011) Neuroimage , vol.59 , Issue.3 , pp. 2142-2154
    • Power, J.D.1    Barnes, K.A.2    Snyder, A.Z.3    Schlaggar, B.L.4    Petersen, S.E.5
  • 32
    • 57749186883 scopus 로고    scopus 로고
    • A new method for improving functional-to-structural MRI alignment using local pearson correlation
    • PID: 1897671
    • Saad, Z., Glen, D., Chen, G., Beauchamp, M., Desai, R., Cox, R. (2009). A new method for improving functional-to-structural MRI alignment using local pearson correlation. Neuroimage, 44(3), 839–848.
    • (2009) Neuroimage , vol.44 , Issue.3 , pp. 839-848
    • Saad, Z.1    Glen, D.2    Chen, G.3    Beauchamp, M.4    Desai, R.5    Cox, R.6
  • 34
    • 84894384080 scopus 로고    scopus 로고
    • Automatic denoising of functional mri data: combining independent component analysis and hierarchical fusion of classifiers
    • PID: 2438942
    • Salimi-Khorshidi, G., Douaud, G., Beckmann, C.F., Glasser, M.F., Griffanti, L., Smith, S.M. (2014). Automatic denoising of functional mri data: combining independent component analysis and hierarchical fusion of classifiers. NeuroImage, 90, 449– 468.
    • (2014) NeuroImage , vol.90 , pp. 449-468
    • Salimi-Khorshidi, G.1    Douaud, G.2    Beckmann, C.F.3    Glasser, M.F.4    Griffanti, L.5    Smith, S.M.6
  • 37
    • 84859705233 scopus 로고    scopus 로고
    • Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty
    • Setsompop, K., Gagoski, B.A., Polimeni, J.R., Witzel, T., Wedeen, V.J., Wald, L.L. (2012). Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magnetic Resonance in Medicine, 67(5), 1210–1224.
    • (2012) Magnetic Resonance in Medicine , vol.67 , Issue.5 , pp. 1210-1224
    • Setsompop, K.1    Gagoski, B.A.2    Polimeni, J.R.3    Witzel, T.4    Wedeen, V.J.5    Wald, L.L.6
  • 38
    • 0031596012 scopus 로고    scopus 로고
    • 0 and parameter mapping using multi image EPI. Magnetic Resonance in Medicine, 40(2), 243–24
    • 0 and T2∗${T}_{2}^{*}$ parameter mapping using multi image EPI. Magnetic Resonance in Medicine, 40(2), 243–248.
  • 39
    • 84897443176 scopus 로고    scopus 로고
    • Studying the spatial distribution of physiological effects on bold signals using ultrafast fmri
    • Tong, Y., & et al. (2014). Studying the spatial distribution of physiological effects on bold signals using ultrafast fmri. Frontiers in human neuroscience, 8.
    • (2014) Frontiers in human neuroscience , pp. 8
    • Tong, Y.1
  • 40
    • 84862993537 scopus 로고    scopus 로고
    • The future of the human connectome
    • Van Essen, D.C., & Ugurbil, K. (2012). The future of the human connectome. Neuroimage, 62(2), 1299–1310.
    • (2012) Neuroimage , vol.62 , Issue.2 , pp. 1299-1310
    • Van Essen, D.C.1    Ugurbil, K.2
  • 41
    • 84897999028 scopus 로고    scopus 로고
    • Regional variations in vascular density correlate with resting-state and task-evoked blood oxygen level-dependent signal amplitude
    • PID: 2384326
    • Vigneau-Roy, N., Bernier, M., Descoteaux, M., Whittingstall, K. (2014). Regional variations in vascular density correlate with resting-state and task-evoked blood oxygen level-dependent signal amplitude. Human brain mapping, 35(5), 1906–1920.
    • (2014) Human brain mapping , vol.35 , Issue.5 , pp. 1906-1920
    • Vigneau-Roy, N.1    Bernier, M.2    Descoteaux, M.3    Whittingstall, K.4
  • 42
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong, E.C., Buxton, R.B., Frank, L.R. (1997). Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR in Biomedicine, 10(45), 237249.
    • (1997) NMR in Biomedicine , vol.10 , Issue.45 , pp. 237249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 43
    • 33750614497 scopus 로고    scopus 로고
    • Advanced three-dimensional tailored rf pulse for signal recovery in $T_{2}^{*}$T2∗-weighted functional magnetic resonance imaging
    • PID: 1704191
    • Yip, C., Fessler, J.A., Noll, D.C. (2006). Advanced three-dimensional tailored rf pulse for signal recovery in T2∗$T_{2}^{*}$-weighted functional magnetic resonance imaging. Magnetic resonance in medicine, 56(5), 1050–1059.
    • (2006) Magnetic resonance in medicine , vol.56 , Issue.5 , pp. 1050-1059
    • Yip, C.1    Fessler, J.A.2    Noll, D.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.