메뉴 건너뛰기




Volumn 16, Issue 1, 2014, Pages 192-201

Factors Influencing Aerodynamic Particle Size Distribution of Suspension Pressurized Metered Dose Inhalers

Author keywords

aerodynamic particle size distribution (APSD); formulation; pressurized metered dose inhaler (pMDI); suspension

Indexed keywords

ALCOHOL; NORFLURANE; SALBUTAMOL SULFATE; AEROSOL; COLLOID; SALBUTAMOL;

EID: 84925461496     PISSN: None     EISSN: 15309932     Source Type: Journal    
DOI: 10.1208/s12249-014-0210-z     Document Type: Article
Times cited : (43)

References (11)
  • 1
    • 0022889862 scopus 로고
    • Deposition of particles in the human respiratory tract in the size range 0.005–15 μm
    • Heyder J, Gebhart J, Rudolf G, Schiller CF, Stahlhofen W. Deposition of particles in the human respiratory tract in the size range 0.005–15 μm. J Aerosol Sci. 1986;17(5):811–25.
    • (1986) J Aerosol Sci , vol.17 , Issue.5 , pp. 811-825
    • Heyder, J.1    Gebhart, J.2    Rudolf, G.3    Schiller, C.F.4    Stahlhofen, W.5
  • 2
    • 84883877806 scopus 로고    scopus 로고
    • The influence of initial atomized droplet size on residual particle size from pressurized metered dose inhalers
    • COI: 1:CAS:528:DC%2BC3sXht1Crt7fM, PID: 23911912
    • Sheth P, Stein SW, Myrdal PB. The influence of initial atomized droplet size on residual particle size from pressurized metered dose inhalers. Int J Pharm. 2013;455:57–65.
    • (2013) Int J Pharm , vol.455 , pp. 57-65
    • Sheth, P.1    Stein, S.W.2    Myrdal, P.B.3
  • 3
    • 0021971366 scopus 로고
    • Development of a systematic theory of suspension inhalation aerosols. I. A framework to study the effects of aggregation on the aerodynamic behaviour of drug particles
    • COI: 1:CAS:528:DyaL28XhtVGhtw%3D%3D
    • Gonda I. Development of a systematic theory of suspension inhalation aerosols. I. A framework to study the effects of aggregation on the aerodynamic behaviour of drug particles. Int J Pharm. 1985;27:99–116.
    • (1985) Int J Pharm , vol.27 , pp. 99-116
    • Gonda, I.1
  • 4
    • 0014324654 scopus 로고
    • The dilution of monodispersed suspensions for aerosolization
    • COI: 1:STN:280:DyaF1M%2FmsVCqtQ%3D%3D, PID: 5727080
    • Raabe OG. The dilution of monodispersed suspensions for aerosolization. Am Ind Hyg Assoc J. 1968;29:439–43.
    • (1968) Am Ind Hyg Assoc J , vol.29 , pp. 439-443
    • Raabe, O.G.1
  • 5
    • 84655173219 scopus 로고    scopus 로고
    • Modeling MDI delivery: a priori predictions, empirical models and experiments
    • Stein SW, Sheth P, Karayiannis C, Chiou H, Myrdal PB. Modeling MDI delivery: a priori predictions, empirical models and experiments. Resp Drug Deliv. 2010;1:353–64.
    • (2010) Resp Drug Deliv , vol.1 , pp. 353-364
    • Stein, S.W.1    Sheth, P.2    Karayiannis, C.3    Chiou, H.4    Myrdal, P.B.5
  • 6
    • 84655176372 scopus 로고    scopus 로고
    • A model for predicting size distributions delivered from pMDIs with suspended drug
    • COI: 1:CAS:528:DC%2BC3MXhs1Kqtb%2FM, PID: 22044537
    • Stein SW, Sheth P, Myrdal PB. A model for predicting size distributions delivered from pMDIs with suspended drug. Int J Pharm. 2012;422(1):101–15.
    • (2012) Int J Pharm , vol.422 , Issue.1 , pp. 101-115
    • Stein, S.W.1    Sheth, P.2    Myrdal, P.B.3
  • 7
    • 3843075402 scopus 로고    scopus 로고
    • A theoretical and experimental analysis of formulation and device parameters affecting solution MDI size distributions
    • COI: 1:CAS:528:DC%2BD2cXmvVKktbo%3D, PID: 15236462
    • Stein SW, Myrdal PB. A theoretical and experimental analysis of formulation and device parameters affecting solution MDI size distributions. J Pharm Sci. 2004;93(8):2158–75.
    • (2004) J Pharm Sci , vol.93 , Issue.8 , pp. 2158-2175
    • Stein, S.W.1    Myrdal, P.B.2
  • 8
    • 84655174502 scopus 로고    scopus 로고
    • The influence of sample size on the accuracy of particle size distribution measurements
    • Stein SW. The influence of sample size on the accuracy of particle size distribution measurements. Resp Drug Deliv. 2008;333–336.
    • (2008) Resp Drug Deliv , pp. 333-336
    • Stein, S.W.1
  • 9
    • 77954213201 scopus 로고    scopus 로고
    • Preparation and utility of sub-micron lactose, a novel excipient for HFA MDI suspension formulations
    • Jinks PA. Preparation and utility of sub-micron lactose, a novel excipient for HFA MDI suspension formulations. Proceedings of Drug Delivery to the Lungs, 14; 2003.
    • (2003) Proceedings of Drug Delivery to the Lungs , pp. 14
    • Jinks, P.A.1
  • 10
    • 47949094123 scopus 로고    scopus 로고
    • The surface characterisation and comparison of two potential sub-micron, sugar bulking excipients for use in low-dose, suspension formulations in metered dose inhalers
    • COI: 1:CAS:528:DC%2BD1cXpt1alsrg%3D, PID: 18577435
    • James J, Crean B, Davies M, Toon R, Jinks P, Roberts CJ. The surface characterisation and comparison of two potential sub-micron, sugar bulking excipients for use in low-dose, suspension formulations in metered dose inhalers. Int J Pharm. 2008;361(1):209–21.
    • (2008) Int J Pharm , vol.361 , Issue.1 , pp. 209-221
    • James, J.1    Crean, B.2    Davies, M.3    Toon, R.4    Jinks, P.5    Roberts, C.J.6
  • 11
    • 44849090657 scopus 로고    scopus 로고
    • Estimating the number of droplets and drug particles emitted from MDIs
    • COI: 1:CAS:528:DC%2BC3cXosFGntrg%3D, PID: 18446470
    • Stein SW. Estimating the number of droplets and drug particles emitted from MDIs. AAPS PharmSciTech. 2008;9(1):112–5.
    • (2008) AAPS PharmSciTech , vol.9 , Issue.1 , pp. 112-115
    • Stein, S.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.