메뉴 건너뛰기




Volumn , Issue , 2000, Pages

Temperature and installation effects on small commercial ultrasonic flow meters

Author keywords

Ultrasonic flow meter temperature installation effects district heating

Indexed keywords

DISTRICT HEATING; ERRORS; FLOW MEASUREMENT; HEATING; PIPE FITTINGS; ULTRASONIC FLOWMETERS;

EID: 84925357361     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (5)
  • 1
    • 0344856179 scopus 로고
    • Installation effects on single and dual-beam ultrasonic flowmeters
    • National Engineering Laboratory June. paper 11.1
    • P. Højholt. Installation effects on single and dual-beam ultrasonic flowmeters. In International conference on flow measurement in the mid 80's. National Engineering Laboratory, June, 1986. paper 11.1.
    • (1986) International Conference on Flow Measurement in the Mid 80's
    • Højholt, P.1
  • 2
    • 0001821826 scopus 로고
    • The performance of transit time ultrasonic flowmeters under good and disturbed flow conditions
    • J. E. Heritage. The performance of transit time ultrasonic flowmeters under good and disturbed flow conditions. Flow Measurement and Instrumentation, volume 1(number 1):pages 24-30, 1989.
    • (1989) Flow Measurement and Instrumentation , vol.1 , Issue.1 , pp. 24-30
    • Heritage, J.E.1
  • 5
    • 85002270302 scopus 로고    scopus 로고
    • Installation effects on an ultrasonic flow meter
    • Carl Carlander and Jerker Delsing. Installation effects on an ultrasonic flow meter. In Proc. FLOMEKO'98, 1998.
    • (1998) Proc. FLOMEKO'98
    • Carlander, C.1    Delsing, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.