메뉴 건너뛰기




Volumn 245, Issue , 2015, Pages 137-146

Comparison of BCG artifact removal methods for evoked responses in simultaneous EEG-fMRI

Author keywords

Artifact removal; BCG artifact; Optimization; Sensory evoked potentials; Signal to noise ratio; Simultaneous EEG fMRI

Indexed keywords

ALGORITHM; ARTICLE; BRAIN FUNCTION; COMPARATIVE STUDY; ELECTROENCEPHALOGRAM; EVOKED RESPONSE; EVOKED VISUAL RESPONSE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; MECHANOCARDIOGRAPHY; PRIORITY JOURNAL; SIGNAL NOISE RATIO; ADULT; ADVERSE EFFECTS; ANALYSIS OF VARIANCE; ARTIFACT; AUDITORY STIMULATION; BLOOD; BRAIN; BRAIN MAPPING; ELECTROENCEPHALOGRAPHY; FEMALE; HEMISPHERIC DOMINANCE; HUMAN; IMAGE PROCESSING; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHOTOSTIMULATION; PHYSIOLOGY; SPECTROSCOPY; VASCULARIZATION; YOUNG ADULT;

EID: 84925251368     PISSN: 01650270     EISSN: 1872678X     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2015.02.018     Document Type: Article
Times cited : (14)

References (34)
  • 1
    • 0033870442 scopus 로고    scopus 로고
    • A method for removing imaging artifact from continuous EEG recorded during functional MRI
    • Allen P.J., Josephs O., Turner R. A method for removing imaging artifact from continuous EEG recorded during functional MRI. NeuroImage 2000, 12:230-239.
    • (2000) NeuroImage , vol.12 , pp. 230-239
    • Allen, P.J.1    Josephs, O.2    Turner, R.3
  • 2
    • 0032189998 scopus 로고    scopus 로고
    • Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction
    • Allen P.J., Polizzi G., Krakow K., Fish D.R., Lemieux L. Identification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtraction. NeuroImage 1998, 8:229-239.
    • (1998) NeuroImage , vol.8 , pp. 229-239
    • Allen, P.J.1    Polizzi, G.2    Krakow, K.3    Fish, D.R.4    Lemieux, L.5
  • 3
    • 77950298913 scopus 로고    scopus 로고
    • Effect of the static magnetic field of the MR-scanner on ERPs: Evaluation of visual, cognitive and motor potentials
    • Assecondi S., Vanderperren K., Novitskiy N., Ramautar J.R., Fias W., Staelens S., et al. Effect of the static magnetic field of the MR-scanner on ERPs: Evaluation of visual, cognitive and motor potentials. Clin Neurophysiol 2010, 121:672-685.
    • (2010) Clin Neurophysiol , vol.121 , pp. 672-685
    • Assecondi, S.1    Vanderperren, K.2    Novitskiy, N.3    Ramautar, J.R.4    Fias, W.5    Staelens, S.6
  • 4
    • 27744579731 scopus 로고    scopus 로고
    • Visual evoked potentials recovered from fMRI scan periods
    • Becker R., Ritter P., Moosmann M., Villringer A. Visual evoked potentials recovered from fMRI scan periods. Hum Brain Mapp 2005, 26:221-230.
    • (2005) Hum Brain Mapp , vol.26 , pp. 221-230
    • Becker, R.1    Ritter, P.2    Moosmann, M.3    Villringer, A.4
  • 6
    • 34547831040 scopus 로고    scopus 로고
    • Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact
    • Debener S., Strobel A., Sorger B., Peters J., Kranczioch C., Engel A.K., et al. Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact. NeuroImage 2007, 34:587-597.
    • (2007) NeuroImage , vol.34 , pp. 587-597
    • Debener, S.1    Strobel, A.2    Sorger, B.3    Peters, J.4    Kranczioch, C.5    Engel, A.K.6
  • 7
    • 30744465379 scopus 로고    scopus 로고
    • Trial-by-trial coupling of concurrent electroencephalogram and functional magnetic resonance imaging identifies the dynamics of performance monitoring
    • Debener S., Ullsperger M., Siegel M., Fiehler K., von Cramon D.Y., Engel A.K. Trial-by-trial coupling of concurrent electroencephalogram and functional magnetic resonance imaging identifies the dynamics of performance monitoring. J Neurosci 2005, 25:11730-11737.
    • (2005) J Neurosci , vol.25 , pp. 11730-11737
    • Debener, S.1    Ullsperger, M.2    Siegel, M.3    Fiehler, K.4    von Cramon, D.Y.5    Engel, A.K.6
  • 8
    • 1242283941 scopus 로고    scopus 로고
    • EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis
    • Delorme A., Makeig S. EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J Neurosci Methods 2004, 134:9-21.
    • (2004) J Neurosci Methods , vol.134 , pp. 9-21
    • Delorme, A.1    Makeig, S.2
  • 10
    • 29144470047 scopus 로고    scopus 로고
    • Assessing the spatiotemporal evolution of neuronal activation with single-trial event-related potentials and functional MRI
    • Eichele T., Specht K., Moosmann M., Jongsma M.L.A., Quiroga R.Q., Nordby H., et al. Assessing the spatiotemporal evolution of neuronal activation with single-trial event-related potentials and functional MRI. Proc Natl Acad Sci USA 2005, 102:17798-17803.
    • (2005) Proc Natl Acad Sci USA , vol.102 , pp. 17798-17803
    • Eichele, T.1    Specht, K.2    Moosmann, M.3    Jongsma, M.L.A.4    Quiroga, R.Q.5    Nordby, H.6
  • 11
    • 3242665483 scopus 로고    scopus 로고
    • Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI
    • Ellingson M.L., Liebenthal E., Spanaki M.V., Prieto T.E., Binder J.R., Ropella K.M. Ballistocardiogram artifact reduction in the simultaneous acquisition of auditory ERPS and fMRI. NeuroImage 2004, 22:1534-1542.
    • (2004) NeuroImage , vol.22 , pp. 1534-1542
    • Ellingson, M.L.1    Liebenthal, E.2    Spanaki, M.V.3    Prieto, T.E.4    Binder, J.R.5    Ropella, K.M.6
  • 12
    • 67949083429 scopus 로고    scopus 로고
    • Ultrahigh-frequency EEG during fMRI: pushing the limits of imaging-artifact correction
    • Freyer F., Becker R., Anami K., Curio G., Villringer A., Ritter P. Ultrahigh-frequency EEG during fMRI: pushing the limits of imaging-artifact correction. NeuroImage 2009, 48:94-108.
    • (2009) NeuroImage , vol.48 , pp. 94-108
    • Freyer, F.1    Becker, R.2    Anami, K.3    Curio, G.4    Villringer, A.5    Ritter, P.6
  • 16
    • 67349153307 scopus 로고    scopus 로고
    • Single-trial discrimination for integrating simultaneous EEG and fMRI: identifying cortical areas contributing to trial-to-trial variability in the auditory oddball task
    • Goldman R.I., Wei C., Philiastides M.G., Gerson A.D., Friedman D., Brown T.R., et al. Single-trial discrimination for integrating simultaneous EEG and fMRI: identifying cortical areas contributing to trial-to-trial variability in the auditory oddball task. NeuroImage 2009, 47:136-147.
    • (2009) NeuroImage , vol.47 , pp. 136-147
    • Goldman, R.I.1    Wei, C.2    Philiastides, M.G.3    Gerson, A.D.4    Friedman, D.5    Brown, T.R.6
  • 18
    • 40649090533 scopus 로고    scopus 로고
    • Low frequency BOLD fluctuations during resting wakefulness and light sleep: a simultaneous EEG-fMRI study
    • Horovitz S.G., Fukunaga M., de Zwart J.A., van Gelderen P., Fulton S.C., Balkin T.J., et al. Low frequency BOLD fluctuations during resting wakefulness and light sleep: a simultaneous EEG-fMRI study. Hum Brain Mapp 2008, 29:671-682.
    • (2008) Hum Brain Mapp , vol.29 , pp. 671-682
    • Horovitz, S.G.1    Fukunaga, M.2    de Zwart, J.A.3    van Gelderen, P.4    Fulton, S.C.5    Balkin, T.J.6
  • 20
    • 0141814601 scopus 로고    scopus 로고
    • Electroencephalographic signatures of attentional and cognitive default modes in spontaneous brain activity fluctuations at rest
    • Laufs H., Krakow K., Sterzer P., Eger E., Beyerle A., Salek-Haddadi A., et al. Electroencephalographic signatures of attentional and cognitive default modes in spontaneous brain activity fluctuations at rest. Proc Natl Acad Sci USA 2003, 100:11053-11058.
    • (2003) Proc Natl Acad Sci USA , vol.100 , pp. 11053-11058
    • Laufs, H.1    Krakow, K.2    Sterzer, P.3    Eger, E.4    Beyerle, A.5    Salek-Haddadi, A.6
  • 21
    • 33744769073 scopus 로고    scopus 로고
    • Automated single-trial measurement of amplitude and latency of laser-evoked potentials (LEPs) using multiple linear regression
    • Mayhew S.D., Iannetti G.D., Woolrich M.W., Wise R.G. Automated single-trial measurement of amplitude and latency of laser-evoked potentials (LEPs) using multiple linear regression. Clin Neurophysiol 2006, 117:1331-1344.
    • (2006) Clin Neurophysiol , vol.117 , pp. 1331-1344
    • Mayhew, S.D.1    Iannetti, G.D.2    Woolrich, M.W.3    Wise, R.G.4
  • 22
    • 70349970973 scopus 로고    scopus 로고
    • EEG signatures of auditory activity correlate with simultaneously recorded fMRI responses in humans
    • Mayhew S.D., Dirckx S.G., Niazy R.K., Iannetti G.D., Wise R.G. EEG signatures of auditory activity correlate with simultaneously recorded fMRI responses in humans. NeuroImage 2010, 49:849-864.
    • (2010) NeuroImage , vol.49 , pp. 849-864
    • Mayhew, S.D.1    Dirckx, S.G.2    Niazy, R.K.3    Iannetti, G.D.4    Wise, R.G.5
  • 23
    • 77956870275 scopus 로고    scopus 로고
    • Coupling of simultaneously acquired electrophysiological and haemodynamic responses during visual stimulation
    • Mayhew S.D., Macintosh B.J., Dirckx S.G., Iannetti G.D., Wise R.G. Coupling of simultaneously acquired electrophysiological and haemodynamic responses during visual stimulation. Magn Reson Imaging 2010, 28:1066-1077.
    • (2010) Magn Reson Imaging , vol.28 , pp. 1066-1077
    • Mayhew, S.D.1    Macintosh, B.J.2    Dirckx, S.G.3    Iannetti, G.D.4    Wise, R.G.5
  • 25
    • 0141869892 scopus 로고    scopus 로고
    • Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy
    • Moosmann M., Ritter P., Krastel I., Brink A., Thees S., Blankenburg F., et al. Correlates of alpha rhythm in functional magnetic resonance imaging and near infrared spectroscopy. NeuroImage 2003, 20:145-158.
    • (2003) NeuroImage , vol.20 , pp. 145-158
    • Moosmann, M.1    Ritter, P.2    Krastel, I.3    Brink, A.4    Thees, S.5    Blankenburg, F.6
  • 26
    • 0032006582 scopus 로고    scopus 로고
    • A new interpretation of nonlinear energy operator and its efficacy in spike detection
    • Mukhopadhyay S., Ray G.C. A new interpretation of nonlinear energy operator and its efficacy in spike detection. IEEE Trans Biomed Eng 1998, 45:180-187.
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 180-187
    • Mukhopadhyay, S.1    Ray, G.C.2
  • 27
    • 25844503100 scopus 로고    scopus 로고
    • Sound level dependence of the primary auditory cortex: simultaneous measurement with 61-channel EEG and fMRI
    • Mulert C., Jager L., Propp S., Karch S., Stormann S., Pogarell O., et al. Sound level dependence of the primary auditory cortex: simultaneous measurement with 61-channel EEG and fMRI. NeuroImage 2005, 28:49-58.
    • (2005) NeuroImage , vol.28 , pp. 49-58
    • Mulert, C.1    Jager, L.2    Propp, S.3    Karch, S.4    Stormann, S.5    Pogarell, O.6
  • 29
    • 27544446124 scopus 로고    scopus 로고
    • Removal of FMRI environment artifacts from EEG data using optimal basis sets
    • Niazy R.K., Beckmann C.F., Iannetti G.D., Brady J.M., Smith S.M. Removal of FMRI environment artifacts from EEG data using optimal basis sets. NeuroImage 2005, 28:720-737.
    • (2005) NeuroImage , vol.28 , pp. 720-737
    • Niazy, R.K.1    Beckmann, C.F.2    Iannetti, G.D.3    Brady, J.M.4    Smith, S.M.5
  • 31
    • 33646557029 scopus 로고    scopus 로고
    • Hemodynamic correlates of epileptiform discharges: an EEG-fMRI study of 63 patients with focal epilepsy
    • Salek-Haddadi A., Diehl B., Hamandi K., Merschhemke M., Liston A., Friston K., et al. Hemodynamic correlates of epileptiform discharges: an EEG-fMRI study of 63 patients with focal epilepsy. Brain Res 2006, 1088:148-166.
    • (2006) Brain Res , vol.1088 , pp. 148-166
    • Salek-Haddadi, A.1    Diehl, B.2    Hamandi, K.3    Merschhemke, M.4    Liston, A.5    Friston, K.6
  • 32
    • 0025670688 scopus 로고
    • Global field power and topographic similarity
    • Skrandies W. Global field power and topographic similarity. Brain Topogr 1990, 3:137-141.
    • (1990) Brain Topogr , vol.3 , pp. 137-141
    • Skrandies, W.1
  • 33
    • 77249083042 scopus 로고    scopus 로고
    • Removal of BCG artifacts from EEG recordings inside the MR scanner: a comparison of methodological and validation-related aspects
    • Vanderperren K., De Vos M., Ramautar J.R., Novitskiy N., Mennes M., Assecondi S., et al. Removal of BCG artifacts from EEG recordings inside the MR scanner: a comparison of methodological and validation-related aspects. NeuroImage 2010, 50:920-934.
    • (2010) NeuroImage , vol.50 , pp. 920-934
    • Vanderperren, K.1    De Vos, M.2    Ramautar, J.R.3    Novitskiy, N.4    Mennes, M.5    Assecondi, S.6
  • 34
    • 77949385638 scopus 로고    scopus 로고
    • Physical modeling of pulse artefact sources in simultaneous EEG/fMRI
    • Yan W.X., Mullinger K.J., Geirsdottir G.B., Bowtell R. Physical modeling of pulse artefact sources in simultaneous EEG/fMRI. Hum Brain Mapp 2010, 31:604-620.
    • (2010) Hum Brain Mapp , vol.31 , pp. 604-620
    • Yan, W.X.1    Mullinger, K.J.2    Geirsdottir, G.B.3    Bowtell, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.