메뉴 건너뛰기




Volumn , Issue , 2014, Pages 1008-1013

Configuration and setting of protection for large-scale wind farm

Author keywords

Configuration and setting; Relay protection; Wind farm

Indexed keywords

ELECTRIC UTILITIES; RELAY PROTECTION; TURBOGENERATORS; WIND POWER; WIND TURBINES;

EID: 84925232895     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/POWERCON.2014.6993938     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 84894469957 scopus 로고    scopus 로고
    • World Wind Energy Association
    • World Wind Energy Association. World wind energy report 2013. [Online]. Available: http://www. wwindea. org/home/index. php
    • (2013) World Wind Energy Report
  • 2
    • 33947658982 scopus 로고    scopus 로고
    • Adaptive distance relay setting for lines connecting wind farms
    • Mar.
    • A. K. Pradhan and G. Joos, "Adaptive distance relay setting for lines connecting wind farms," IEEE Trans. Energy Conversion, vol. 22, pp. 206-213, Mar. 2007
    • (2007) IEEE Trans. Energy Conversion , vol.22 , pp. 206-213
    • Pradhan, A.K.1    Joos, G.2
  • 7
    • 84925240035 scopus 로고    scopus 로고
    • Wind plant collector system fault protection and coordination
    • IEEE PES Wind Plant Collector System Design Working Group
    • IEEE PES Wind Plant Collector System Design Working Group, "Wind Plant Collector System Fault Protection and Coordination," in Proc. 2010 IEEE PES Transmission and Distribution Conf., pp. 1-5.
    • Proc. 2010 IEEE PES Transmission and Distribution Conf , pp. 1-5
  • 9
    • 78649960927 scopus 로고    scopus 로고
    • Analytical study of grid-fault response of wind turbine doubly fed induction generator
    • Dec.
    • Graham. Pannell, D. J. Atkinson and B. Zahawi, "Analytical study of grid-fault response of wind turbine doubly fed induction generator," IEEE Trans. Energy Conversion, vol. 25, pp. 1081-1091, Dec. 2010.
    • (2010) IEEE Trans. Energy Conversion , vol.25 , pp. 1081-1091
    • Graham, P.1    Atkinson, D.J.2    Zahawi, B.3
  • 10
    • 33947634098 scopus 로고    scopus 로고
    • Short-circuit current of wind turbines with doubly fed induction generator
    • Mar.
    • J. Morren and S. W. H. Haan. "Short-circuit current of wind turbines with doubly fed induction generator," IEEE Trans. Energy Conversion, vol. 22, pp. 174-180, Mar. 2007
    • (2007) IEEE Trans. Energy Conversion , vol.22 , pp. 174-180
    • Morren, J.1    Haan, S.W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.