메뉴 건너뛰기




Volumn 8, Issue 9, 2015, Pages 4239-4247

Assessing Calibration Stability Using the Global Precipitation Measurement (GPM) Microwave Imager (GMI) Noise Diodes

Author keywords

Calibration; microwave radiometry; noise diodes

Indexed keywords

CALIBRATION; ORBITS; PRECIPITATION (METEOROLOGY); TEMPERATURE; TRANSIENT ANALYSIS;

EID: 84925047520     PISSN: 19391404     EISSN: 21511535     Source Type: Journal    
DOI: 10.1109/JSTARS.2015.2406661     Document Type: Conference Paper
Times cited : (43)

References (12)
  • 1
    • 84897665733 scopus 로고    scopus 로고
    • The global precipitation measurement mission
    • Y. Hou et al., "The global precipitation measurement mission," Bull. Amer. Meteorol. Soc., vol. 95, pp. 701-722, 2013.
    • (2013) Bull. Amer. Meteorol. Soc. , vol.95 , pp. 701-722
    • Hou, Y.1
  • 2
    • 85027956804 scopus 로고    scopus 로고
    • The global precipitation measurement (GPM) microwave imager (GMI): Instrument overview and early on-orbit performance
    • to be published
    • D. W. Draper et al., "The global precipitation measurement (GPM) microwave imager (GMI): Instrument overview and early on-orbit performance," IEEE J. Sel. Topics Geosci. Remote Sens., 2015, to be published.
    • (2015) IEEE J. Sel. Topics Geosci. Remote Sens.
    • Draper, D.W.1
  • 3
    • 77958097646 scopus 로고    scopus 로고
    • GPM microwave imager selected calibration features and predicted performance
    • J. B. Sechler, "GPM microwave imager selected calibration features and predicted performance," in Proc. IEEE Int. Geosci. Remote Sens. Symp. (IGARSS), 2007, pp. 5237-5239.
    • (2007) Proc IEEE Int. Geosci. Remote Sens. Symp. (IGARSS) , pp. 5237-5239
    • Sechler, J.B.1
  • 4
    • 84874629681 scopus 로고    scopus 로고
    • Global precipitation measurement microwave imager prelaunch hot load calibration
    • Sep.
    • D.W. Draper, D. A. Newell, D. A. Teusch, and P.K. Yoho, "Global precipitation measurement microwave imager prelaunch hot load calibration," IEEE Trans. Geosci. Remote Sens., vol. 41, no. 9, pp. 4731-4742, Sep. 2013.
    • (2013) IEEE Trans. Geosci. Remote Sens. , vol.41 , Issue.9 , pp. 4731-4742
    • Draper, D.W.1    Newell, D.A.2    Teusch, D.A.3    Yoho, P.K.4
  • 5
    • 34250759184 scopus 로고    scopus 로고
    • JMR noise diode stability and recalibration methodology after three years on-orbit
    • S. T. Brown, S. Desai, S. Keihm, and C. Ruf, "JMR noise diode stability and recalibration methodology after three years on-orbit," in Proc. MicroRad, San Juan, Puerto Rico, 2006, pp. 7-12.
    • (2006) Proc. MicroRad, San Juan, Puerto Rico , pp. 7-12
    • Brown, S.T.1    Desai, S.2    Keihm, S.3    Ruf, C.4
  • 6
    • 34347224302 scopus 로고    scopus 로고
    • On the long-tern stability of microwave radiometers using noise diodes for calibration
    • May
    • S. T. Brown, S. Desai, W. Lu, and A. B. Tanner, "On the long-tern stability of microwave radiometers using noise diodes for calibration," IEEE Trans. Geosci. Remote Sens., vol. 45, no. 7, pp. 1908-1920, May 2007.
    • (2007) IEEE Trans. Geosci. Remote Sens. , vol.45 , Issue.7 , pp. 1908-1920
    • Brown, S.T.1    Desai, S.2    Lu, W.3    Tanner, A.B.4
  • 7
    • 84860783705 scopus 로고    scopus 로고
    • GMI calibration algorithm and analysis theoretical basis document
    • Santa Rosa, CA, USA, Rep. 051707
    • T. Meissner and F. J. Wentz, "GMI calibration algorithm and analysis theoretical basis document," Remote Sens. Syst., Santa Rosa, CA, USA, Rep. 051707, 2012.
    • (2012) Remote Sens. Syst.
    • Meissner, T.1    Wentz, F.J.2
  • 8
    • 0034963738 scopus 로고    scopus 로고
    • Recalibration of the NOAA microwave sounding unit
    • T.Mo, M. D. Goldberg, D. S. Crosby, and Z. Cheng, "Recalibration of the NOAA microwave sounding unit," J. Geophys. Res., vol. 106, no. D10, pp. 10,145-10,150, 2001. doi:10.1029/2001JD900027.
    • (2001) J. Geophys. Res. , vol.106 , Issue.10 , pp. 10145-10150
    • Mo, T.1    Goldberg, M.D.2    Crosby, D.S.3    Cheng, Z.4
  • 9
    • 84939505313 scopus 로고    scopus 로고
    • Calibration data book for global precipitation measurement (GPM) microwave imager
    • Boulder, CO, USA, Rep. 2344649 Available
    • D. Draper, "Calibration data book for global precipitation measurement (GPM) microwave imager," Ball Aerosp. Technol. Corp., Boulder, CO, USA, Rep. 2344649, 2014. Available: http://trmmopen.gsfc.nasa.gov
    • (2014) Ball Aerosp. Technol. Corp.
    • Draper, D.1
  • 10
    • 84906775626 scopus 로고    scopus 로고
    • Aquarius radiometer status
    • Pasedena, CA, USA
    • D. M. Levine et al., "Aquarius radiometer status," in Proc. MicroRad, Pasedena, CA, USA, 2014, pp. 226-227.
    • (2014) Proc. MicroRad , pp. 226-227
    • Levine, D.M.1
  • 11
    • 84961942595 scopus 로고    scopus 로고
    • Wikipedia [Online]. Available: Accessed on: Dec. 5, 2014
    • Wikipedia. (2014). DirecTV-10 [Online]. Available: http://en.wikipedia. org/wiki/DirecTV-10. Accessed on: Dec. 5, 2014.
    • (2014) Direc TV-10
  • 12
    • 84961859664 scopus 로고    scopus 로고
    • National Telecommunications, Information Administration [Online] 2014 Accessed on: Dec. 5, 2014
    • National Telecommunications & Information Administration. (2014). United States Frequency Allocation Chart [Online] 2014, http://www. ntia.doc.gov/page/2011/united-states-frequency-allocation-chart. Accessed on: Dec. 5, 2014.
    • (2014) United States Frequency Allocation Chart


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.