메뉴 건너뛰기




Volumn 36, Issue 3, 2015, Pages 547-551

Comparison of modern stroke thrombectomy approaches using an in vitro cerebrovascular occlusion model

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFICIAL EMBOLISM; ASPIRATION CATHETER; BALLOON CATHETER; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; DISEASE MODEL; GUIDING CATHETER; OCCLUSIVE CEREBROVASCULAR DISEASE; RECANALIZATION; STENTRIEVER THROMBECTOMY; THROMBECTOMY; THROMBUS ASPIRATION; COMPARATIVE STUDY; DEVICES; FEMALE; HUMAN; INTRACRANIAL THROMBOSIS; PROCEDURES; STROKE; TREATMENT OUTCOME;

EID: 84924916912     PISSN: 01956108     EISSN: 1936959X     Source Type: Journal    
DOI: 10.3174/ajnr.A4149     Document Type: Article
Times cited : (65)

References (15)
  • 1
    • 84867064449 scopus 로고    scopus 로고
    • Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): A randomised trial
    • Nogueira RG, Lutsep HL, Gupta R, et al. Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): a randomised trial. Lancet 2012;380:1231-40
    • (2012) Lancet , vol.380 , pp. 1231-1240
    • Nogueira, R.G.1    Lutsep, H.L.2    Gupta, R.3
  • 2
    • 84867072741 scopus 로고    scopus 로고
    • Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): A randomised, parallel-group, non-inferiority trial
    • Saver JL, Jahan R, Levy EI, et al. Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial. Lancet 2012;380:1241-49
    • (2012) Lancet , vol.380 , pp. 1241-1249
    • Saver, J.L.1    Jahan, R.2    Levy, E.I.3
  • 3
    • 84921054369 scopus 로고    scopus 로고
    • Distal aspiration with retrievable stent assisted thrombectomy for the treatment of acute ischemic stroke
    • Humphries W, Hoit D, Doss VT, et al. Distal aspiration with retrievable stent assisted thrombectomy for the treatment of acute ischemic stroke. J Neurointerv Surg 2015;7:90-94
    • (2015) J Neurointerv Surg , vol.7 , pp. 90-94
    • Humphries, W.1    Hoit, D.2    Doss, V.T.3
  • 4
    • 84880570543 scopus 로고    scopus 로고
    • Solitaire flow restoration thrombectomy for acute ischemic stroke: Retrospective multicenter analysis of early postmarket experience after FDA approval
    • discussion 25-26
    • Mokin M, Dumont TM, Veznedaroglu E, et al. Solitaire flow restoration thrombectomy for acute ischemic stroke: retrospective multicenter analysis of early postmarket experience after FDA approval. Neurosurgery 2013;73:19-25; discussion 25-26
    • (2013) Neurosurgery , vol.73 , pp. 19-25
    • Mokin, M.1    Dumont, T.M.2    Veznedaroglu, E.3
  • 5
    • 84907004072 scopus 로고    scopus 로고
    • North American Solitaire Stent Retriever Acute Stroke registry: Post-marketing revascularization and clinical outcome results
    • Zaidat OO, Castonguay AC, Gupta R, et al. North American Solitaire Stent Retriever Acute Stroke registry: post-marketing revascularization and clinical outcome results. J Neurointerv Surg 2014;6:584-88
    • (2014) J Neurointerv Surg , vol.6 , pp. 584-588
    • Zaidat, O.O.1    Castonguay, A.C.2    Gupta, R.3
  • 6
    • 84897954509 scopus 로고    scopus 로고
    • Initial clinical experience with the ADAPT technique: A direct aspiration first pass technique for stroke thrombectomy
    • Turk AS, Spiotta A, Frei D, et al. Initial clinical experience with the ADAPT technique: a direct aspiration first pass technique for stroke thrombectomy. J Neurointerv Surg 2014;6:231-37
    • (2014) J Neurointerv Surg , vol.6 , pp. 231-237
    • Turk, A.S.1    Spiotta, A.2    Frei, D.3
  • 7
    • 84899638851 scopus 로고    scopus 로고
    • ADAPT FAST study: A direct aspiration first pass technique for acute stroke thrombectomy
    • Turk AS, Frei D, Fiorella D, et al. ADAPT FAST study: a direct aspiration first pass technique for acute stroke thrombectomy. J Neurointerv Surg 2014;6:260-64
    • (2014) J Neurointerv Surg , vol.6 , pp. 260-264
    • Turk, A.S.1    Frei, D.2    Fiorella, D.3
  • 8
    • 84901764901 scopus 로고    scopus 로고
    • Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing
    • Ionita CN, Mokin M, Varble N, et al. Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing. Proc SPIE 2014;9038:90380M
    • (2014) Proc SPIE , vol.9038 , pp. 90380M
    • Ionita, C.N.1    Mokin, M.2    Varble, N.3
  • 9
    • 84924885496 scopus 로고    scopus 로고
    • Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: In vitro stroke model comparison
    • Apr 30. [Epub ahead of print]
    • Mokin M, Ionita CN, Setlur Nagesh SV, et al. Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison. J Neurointerv Surg 2014 Apr 30. [Epub ahead of print]
    • (2014) J Neurointerv Surg
    • Mokin, M.1    Ionita, C.N.2    Setlur Nagesh, S.V.3
  • 11
    • 70350364898 scopus 로고    scopus 로고
    • An experimental study on the ultimate strength of the adventitia and media ofhumanatherosclerotic carotid arteries in circumferential and axial directions
    • Teng Z, Tang D, Zheng J, et al. An experimental study on the ultimate strength of the adventitia and media ofhumanatherosclerotic carotid arteries in circumferential and axial directions. J Biomech 2009;42:2535-39
    • (2009) J Biomech , vol.42 , pp. 2535-2539
    • Teng, Z.1    Tang, D.2    Zheng, J.3
  • 12
    • 84898457997 scopus 로고    scopus 로고
    • Stent retrievers in acute ischemic stroke: Complications and failures during the perioperative period
    • Gascou G, Lobotesis K, Machi P, et al. Stent retrievers in acute ischemic stroke: complications and failures during the perioperative period. AJNR Am J Neuroradiol 2014;35:734-40
    • (2014) AJNR Am J Neuroradiol , vol.35 , pp. 734-740
    • Gascou, G.1    Lobotesis, K.2    Machi, P.3
  • 13
    • 84893813490 scopus 로고    scopus 로고
    • Balloon guide catheter improves revascularization and clinical outcomes with the Solitaire device: Analysis of the North American Solitaire Acute Stroke Registry
    • Nguyen TN, Malisch T, Castonguay AC, et al. Balloon guide catheter improves revascularization and clinical outcomes with the Solitaire device: analysis of the North American Solitaire Acute Stroke Registry. Stroke 2014;45:141-45
    • (2014) Stroke , vol.45 , pp. 141-145
    • Nguyen, T.N.1    Malisch, T.2    Castonguay, A.C.3
  • 14
    • 33747405926 scopus 로고    scopus 로고
    • A dedicated animal model for mechanical thrombectomy in acute stroke
    • Gralla J, Schroth G, Remonda L, et al. A dedicated animal model for mechanical thrombectomy in acute stroke. AJNR Am J Neuroradiol 2006;27:1357-61
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1357-1361
    • Gralla, J.1    Schroth, G.2    Remonda, L.3
  • 15
    • 84897954085 scopus 로고    scopus 로고
    • Hydrodynamic comparison of the Penumbra system and commonly available syringes in forced-suction thrombectomy
    • Simon SD, Grey CP. Hydrodynamic comparison of the Penumbra system and commonly available syringes in forced-suction thrombectomy. J Neurointerv Surg 2014;6:205-11
    • (2014) J Neurointerv Surg , vol.6 , pp. 205-211
    • Simon, S.D.1    Grey, C.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.