메뉴 건너뛰기




Volumn 83, Issue 2, 2015, Pages 176-180

Comparison of polyetheretherketone and titanium cranioplasty after decompressive craniectomy

Author keywords

Complication; Cranioplasty; Implant exposure; PEEK; Polyetheretherketone; Titanium

Indexed keywords

POLYETHERETHERKETONE; TITANIUM; BIOMATERIAL; KETONE; MACROGOL DERIVATIVE;

EID: 84924854557     PISSN: 18788750     EISSN: 18788769     Source Type: Journal    
DOI: 10.1016/j.wneu.2014.06.003     Document Type: Review
Times cited : (143)

References (26)
  • 3
    • 0037386046 scopus 로고    scopus 로고
    • 2) cranial defects with "reinforced" hydroxyapatite cement: Technique and complications
    • 2) cranial defects with "reinforced" hydroxyapatite cement: technique and complications Neurosurgery 52 2003 842 845
    • (2003) Neurosurgery , vol.52 , pp. 842-845
    • Durham, S.R.1    McComb, J.G.2    Levy, M.L.3
  • 4
    • 0035514574 scopus 로고    scopus 로고
    • Computer-assisted prefabrication of individual craniofacial implants
    • H. Eufinger, and B. Saylor Computer-assisted prefabrication of individual craniofacial implants AORN J 74 2001 648 654
    • (2001) AORN J , vol.74 , pp. 648-654
    • Eufinger, H.1    Saylor, B.2
  • 5
    • 39449099869 scopus 로고    scopus 로고
    • Computer-designed implants for fronto-orbital defect reconstruction
    • J.L. Frodel Computer-designed implants for fronto-orbital defect reconstruction Facial Plast Surg 24 2008 22 34
    • (2008) Facial Plast Surg , vol.24 , pp. 22-34
    • Frodel, J.L.1
  • 7
    • 68949085149 scopus 로고    scopus 로고
    • Complications of cranioplasty following decompressive craniectomy: Analysis of 62 cases
    • M.R. Gooch, G.E. Gin, T.J. Kenning, and J.W. German Complications of cranioplasty following decompressive craniectomy: analysis of 62 cases Neurosurg Focus 26 2009 E9
    • (2009) Neurosurg Focus , vol.26 , pp. E9
    • Gooch, M.R.1    Gin, G.E.2    Kenning, T.J.3    German, J.W.4
  • 8
    • 66149101319 scopus 로고    scopus 로고
    • Calvarial reconstruction with polyetheretherketone implants
    • M.M. Hanasono, N. Goel, and F. DeMonte Calvarial reconstruction with polyetheretherketone implants Ann Plast Surg 62 2009 653 655
    • (2009) Ann Plast Surg , vol.62 , pp. 653-655
    • Hanasono, M.M.1    Goel, N.2    Demonte, F.3
  • 10
    • 84871805916 scopus 로고    scopus 로고
    • How "successful" is using calvarial reconstruction using frozen autologous bone?
    • S. Honeybul, and K.M. Ho How "successful" is using calvarial reconstruction using frozen autologous bone? Plast Reconstr Surg 130 2012 1110 1117
    • (2012) Plast Reconstr Surg , vol.130 , pp. 1110-1117
    • Honeybul, S.1    Ho, K.M.2
  • 11
    • 0033458787 scopus 로고    scopus 로고
    • A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome
    • J. Joffee, M. Harris, F. Kahugu, S. Nicoll, A. Linney, and R. Richards A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome Br J Neurosurg 13 1999 576 580
    • (1999) Br J Neurosurg , vol.13 , pp. 576-580
    • Joffee, J.1    Harris, M.2    Kahugu, F.3    Nicoll, S.4    Linney, A.5    Richards, R.6
  • 12
    • 0035016865 scopus 로고    scopus 로고
    • Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems
    • J.J. Kuttenberger, and N. Hardt Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems J Craniomaxillofac Surg 29 2001 75 81
    • (2001) J Craniomaxillofac Surg , vol.29 , pp. 75-81
    • Kuttenberger, J.J.1    Hardt, N.2
  • 13
    • 79953172861 scopus 로고    scopus 로고
    • Computer-assisted designed and computer-assisted manufactured polyetheretherketone prosthesis for complex fronto-orbito-temporo defect
    • J.B. Lai, S. Sittitavornwong, and P.D. Waite Computer-assisted designed and computer-assisted manufactured polyetheretherketone prosthesis for complex fronto-orbito-temporo defect J Oral Maxillofac Surg 69 2011 1175 1180
    • (2011) J Oral Maxillofac Surg , vol.69 , pp. 1175-1180
    • Lai, J.B.1    Sittitavornwong, S.2    Waite, P.D.3
  • 15
    • 0033954042 scopus 로고    scopus 로고
    • A new technique for cranioplasty with L-shaped titanium plates and combination ceramic implants composed of hydroxyapatite and tricalcium phosphate (Ceratite)
    • H. Miyake, T. Ohta, and H. Tanaka A new technique for cranioplasty with L-shaped titanium plates and combination ceramic implants composed of hydroxyapatite and tricalcium phosphate (Ceratite) Neurosurgery 46 2000 414 418
    • (2000) Neurosurgery , vol.46 , pp. 414-418
    • Miyake, H.1    Ohta, T.2    Tanaka, H.3
  • 16
    • 77955806398 scopus 로고    scopus 로고
    • Craniofacial reconstruction with bone and biomaterials: Review over the last 11 years
    • E. Neovius, and T. Engstrand Craniofacial reconstruction with bone and biomaterials: review over the last 11 years J Plast Reconstr Aesthet Surg 63 2010 1615 1623
    • (2010) J Plast Reconstr Aesthet Surg , vol.63 , pp. 1615-1623
    • Neovius, E.1    Engstrand, T.2
  • 17
    • 0031093586 scopus 로고    scopus 로고
    • Repairing holes in the head: A history of cranioplasty
    • A. Sannan, and S.J. Haines Repairing holes in the head: a history of cranioplasty Neurosurgery 40 1997 588 603
    • (1997) Neurosurgery , vol.40 , pp. 588-603
    • Sannan, A.1    Haines, S.J.2
  • 18
    • 84859917059 scopus 로고    scopus 로고
    • Cranioplasty after decompressive craniectomy: The effect of timing on postoperative complications
    • P. Schuss, G. Marquardt, L. Imöhl, C.T. Ulrich, V. Seifert, and E. Güresir Cranioplasty after decompressive craniectomy: the effect of timing on postoperative complications J Neurotrauma 29 2012 1090 1095
    • (2012) J Neurotrauma , vol.29 , pp. 1090-1095
    • Schuss, P.1    Marquardt, G.2    Imöhl, L.3    Ulrich, C.T.4    Seifert, V.5    Güresir, E.6
  • 19
    • 33846587469 scopus 로고    scopus 로고
    • Complex orbito-fronto-temporal reconstruction using computer designed PEEK implant
    • P. Scolozzi, A. Martinez, and B. Jaques Complex orbito-fronto-temporal reconstruction using computer designed PEEK implant J Craniofac Surg 18 2007 224 228
    • (2007) J Craniofac Surg , vol.18 , pp. 224-228
    • Scolozzi, P.1    Martinez, A.2    Jaques, B.3
  • 20
    • 0001617653 scopus 로고
    • Titanium in cranioplasty
    • D. Simpson Titanium in cranioplasty J Neurosurg 22 1965 292 293
    • (1965) J Neurosurg , vol.22 , pp. 292-293
    • Simpson, D.1
  • 22
    • 84875183876 scopus 로고    scopus 로고
    • Use of "custom made" porous hydroxyapatite implants for cranioplasty: Postoperative analysis of complications in 1549 patients
    • R. Stefini, G. Esposito, B. Zanotti, C. Iaccarino, M.M. Fontanella, and F. Servadei Use of "custom made" porous hydroxyapatite implants for cranioplasty: postoperative analysis of complications in 1549 patients Surg Neurol Int 4 2013 12
    • (2013) Surg Neurol Int , vol.4 , pp. 12
    • Stefini, R.1    Esposito, G.2    Zanotti, B.3    Iaccarino, C.4    Fontanella, M.M.5    Servadei, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.