메뉴 건너뛰기




Volumn , Issue , 2014, Pages 412-419

Control of exposure to exhaled air from sick occupant with wearable personal exhaust unit

Author keywords

Airborne cross infection; Contaminant control; Full scale measurements; Hospital ventilation; Wearable personalized exhaust unit

Indexed keywords

AIR QUALITY; HOSPITALS; INDOOR AIR POLLUTION; MIXING; VENTILATION EXHAUSTS; WEARABLE TECHNOLOGY;

EID: 84924705737     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0003610516 scopus 로고    scopus 로고
    • American Institute of Architects, Academy of Architecture for Health, Facilities Guidelines Institute, United States, Washington, DC
    • AIA (2001) Guidelines for design and construction of hospital and health care facilities. American Institute of Architects, Academy of Architecture for Health, Facilities Guidelines Institute, United States, Washington, DC.
    • (2001) Guidelines for Design and Construction of Hospital and Health Care Facilities
    • AIA1
  • 2
    • 78651435013 scopus 로고    scopus 로고
    • ASHRAE/ASHE Standard, 170 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA
    • ASHRAE/ASHE Standard, 170 (2008) Ventilation of Health Care Facilities. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
    • (2008) Ventilation of Health Care Facilities
  • 3
    • 84905779242 scopus 로고    scopus 로고
    • Second edition, Spon Press, Taylor & Francis Group, London and New York
    • Awbi H (2003) Ventilation of Buildings. Second edition, Spon Press, Taylor & Francis Group, London and New York.
    • (2003) Ventilation of Buildings
    • Awbi, H.1
  • 5
    • 60749111474 scopus 로고    scopus 로고
    • Methods for air cleaning and protection of building occupants from airborne pathogens
    • Bolashikov ZD and Melikov AK (2009) Methods for air cleaning and protection of building occupants from airborne pathogens. Building and Environment, 44, 1378-1385.
    • (2009) Building and Environment , vol.44 , pp. 1378-1385
    • Bolashikov, Z.D.1    Melikov, A.K.2
  • 7
    • 84879100315 scopus 로고    scopus 로고
    • Tracer-gas as a surrogate method for tracking airborne pathogen transport in indoor environment
    • Paper ID: a586 4
    • Camargo-Valero M.A., GIlkeson CA, Noakes C.J. (2011) Tracer-gas as a surrogate method for tracking airborne pathogen transport in indoor environment. In: Proceedings of Indoor Air, Paper ID: a586 4.
    • (2011) Proceedings of Indoor Air
    • Camargo-Valero, M.A.1    Gilkeson, C.A.2    Noakes, C.J.3
  • 8
    • 8644263177 scopus 로고    scopus 로고
    • Department of Health and Human Services Centers for Disease Control and Prevention, Atlanta, GA, U.S.
    • CDC (2003) Guidelines for environmental infection control in health-care facilities. Department of Health and Human Services Centers for Disease Control and Prevention, Atlanta, GA, U.S.
    • (2003) Guidelines for Environmental Infection Control in Health-care Facilities
    • CDC1
  • 11
    • 84891939048 scopus 로고    scopus 로고
    • Experimental study of gaseous and particulate contaminants distribution in an aircraft cabin
    • Li F, Liu J, Pei J., Lin CH and Chen Q (2014) Experimental study of gaseous and particulate contaminants distribution in an aircraft cabin. Atmospheric Environment, 85, 223-233.
    • (2014) Atmospheric Environment , vol.85 , pp. 223-233
    • Li, F.1    Liu, J.2    Pei, J.3    Lin, C.H.4    Chen, Q.5
  • 12
    • 33846635560 scopus 로고    scopus 로고
    • Indoor air quality assessment by a breathing thermal manikin
    • Melikov AK and Kaczmarczyk J (2007) Indoor air quality assessment by a breathing thermal manikin. Indoor Air, 17 (1), 50-59.
    • (2007) Indoor Air , vol.17 , Issue.1 , pp. 50-59
    • Melikov, A.K.1    Kaczmarczyk, J.2
  • 14
    • 84855317290 scopus 로고    scopus 로고
    • Novel ventilation strategy for reducing the risk of cross infection in hospital rooms
    • Paper 1037
    • Melikov A, Bolashikov Z, Georgiev E. (2011) Novel ventilation strategy for reducing the risk of cross infection in hospital rooms. In: Proceedings of Indoor Air, Paper 1037.
    • (2011) Proceedings of Indoor Air
    • Melikov, A.1    Bolashikov, Z.2    Georgiev, E.3
  • 15
    • 84879098915 scopus 로고    scopus 로고
    • Examination on performance of headset incorporated personalized ventilation unit using CFD method
    • Paper ID: 1018, Copenhagen. Denmark, 17-22 August
    • Zhu SW, Bolashikov Z and Melikov AK (2008) Examination on performance of headset incorporated personalized ventilation unit using CFD method. In: Proceedings of Indoor Air, Paper ID: 1018, Copenhagen. Denmark, 17-22 August.
    • (2008) Proceedings of Indoor Air
    • Zhu, S.W.1    Bolashikov, Z.2    Melikov, A.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.