메뉴 건너뛰기




Volumn 24, Issue 1, 2015, Pages 25-34

A near infrared spectroscopy-based test of calf muscle function in patients with peripheral arterial disease

Author keywords

dynamic and isometric exercise test; near infrared spectroscopy; pedal ergometry; peripheral arterial disease; reproducibility of test measurements; treadmill

Indexed keywords

OXYHEMOGLOBIN;

EID: 84924276697     PISSN: 10611711     EISSN: 16155939     Source Type: Journal    
DOI: 10.1055/s-0035-1544223     Document Type: Article
Times cited : (12)

References (24)
  • 1
    • 33845241195 scopus 로고    scopus 로고
    • Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II)
    • TASC II Working Group. 01
    • Norgren L., Hiatt W. R., Dormandy J. A., et al. TASC II Working Group. Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II). Eur J Vasc Endovasc Surg: 2007; 33 01 S1 S75
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , pp. S1-S75
    • Norgren, L.1    Hiatt, W.R.2    Dormandy, J.A.3
  • 2
    • 60549110741 scopus 로고    scopus 로고
    • Management of lower extremity peripheral arterial disease
    • Gardner A. W., Afaq A. Management of lower extremity peripheral arterial disease. J Cardiopulm Rehabil Prev: 2008; 28 6 349 357
    • (2008) J Cardiopulm Rehabil Prev , vol.28 , Issue.6 , pp. 349-357
    • Gardner, A.W.1    Afaq, A.2
  • 3
    • 33846673596 scopus 로고    scopus 로고
    • Plantar flexion as an alternative to treadmill exercise for evaluating patients with intermittent claudication
    • Yamamoto K., Miyata T., Onozuka A., Koyama H., Ohtsu H., Nagawa H. Plantar flexion as an alternative to treadmill exercise for evaluating patients with intermittent claudication. Eur J Vasc Endovasc Surg: 2007; 33 3 325 329
    • (2007) Eur J Vasc Endovasc Surg , vol.33 , Issue.3 , pp. 325-329
    • Yamamoto, K.1    Miyata, T.2    Onozuka, A.3    Koyama, H.4    Ohtsu, H.5    Nagawa, H.6
  • 4
    • 0031459320 scopus 로고    scopus 로고
    • The Stresst'er ergometer as an alternative to treadmill testing in patients with claudication
    • Cameron A. E., Porter A., Rosser S., Da Silva A. E., De Cossart L. M. The Stresst'er ergometer as an alternative to treadmill testing in patients with claudication. Eur J Vasc Endovasc Surg: 1997; 14 6 433 438
    • (1997) Eur J Vasc Endovasc Surg , vol.14 , Issue.6 , pp. 433-438
    • Cameron, A.E.1    Porter, A.2    Rosser, S.3    Da Silva, A.E.4    De Cossart, L.M.5
  • 5
    • 0026606803 scopus 로고
    • Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
    • Chance B., Dait M. T., Zhang C., Hamaoka T., Hagerman F. Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers. Am J Physiol: 1992; 262 3 Pt 1 C766 C775
    • (1992) Am J Physiol , vol.262 , Issue.3 , pp. C766-C775
    • Chance, B.1    Dait, M.T.2    Zhang, C.3    Hamaoka, T.4    Hagerman, F.5
  • 6
    • 84869832324 scopus 로고    scopus 로고
    • Principles of exercise physiology: Responses to acute exercise and long-term adaptations to training
    • Rivera-Brown A. M., Frontera W. R. Principles of exercise physiology: responses to acute exercise and long-term adaptations to training. PM R: 2012; 4 11 797 804
    • (2012) PM R , vol.4 , Issue.11 , pp. 797-804
    • Rivera-Brown, A.M.1    Frontera, W.R.2
  • 7
    • 33745242509 scopus 로고    scopus 로고
    • Mitochondrial defects and oxidative damage in patients with peripheral arterial disease
    • Pipinos I. I., Judge A. R., Zhu Z., et al. Mitochondrial defects and oxidative damage in patients with peripheral arterial disease. Free Radic Biol Med: 2006; 41 2 262 269
    • (2006) Free Radic Biol Med , vol.41 , Issue.2 , pp. 262-269
    • Pipinos, I.I.1    Judge, A.R.2    Zhu, Z.3
  • 8
    • 0034067934 scopus 로고    scopus 로고
    • Near-infrared spectroscopy grades the severity of intermittent claudication in diabetics more accurately than ankle pressure measurement
    • Komiyama T., Shigematsu H., Yasuhara H., Muto T. Near-infrared spectroscopy grades the severity of intermittent claudication in diabetics more accurately than ankle pressure measurement. Br J Surg: 2000; 87 4 459 466
    • (2000) Br J Surg , vol.87 , Issue.4 , pp. 459-466
    • Komiyama, T.1    Shigematsu, H.2    Yasuhara, H.3    Muto, T.4
  • 9
    • 4944244438 scopus 로고    scopus 로고
    • Near-infrared spectroscopy with treadmill exercise to assess lower limb ischemia in patients with atherosclerotic occlusive disease
    • Watanabe T., Matsushita M., Nishikimi N., Sakurai T., Komori K., Nimura Y. Near-infrared spectroscopy with treadmill exercise to assess lower limb ischemia in patients with atherosclerotic occlusive disease. Surg Today: 2004; 34 10 849 854
    • (2004) Surg Today , vol.34 , Issue.10 , pp. 849-854
    • Watanabe, T.1    Matsushita, M.2    Nishikimi, N.3    Sakurai, T.4    Komori, K.5    Nimura, Y.6
  • 10
    • 0035650674 scopus 로고    scopus 로고
    • Mitochondrial function and oxygen supply in normal and in chronically ischemic muscle: A combined 31P magnetic resonance spectroscopy and near infrared spectroscopy study in vivo
    • Kemp G. J., Roberts N., Bimson W. E., et al. Mitochondrial function and oxygen supply in normal and in chronically ischemic muscle: a combined 31P magnetic resonance spectroscopy and near infrared spectroscopy study in vivo. J Vasc Surg: 2001; 34 6 1103 1110
    • (2001) J Vasc Surg , vol.34 , Issue.6 , pp. 1103-1110
    • Kemp, G.J.1    Roberts, N.2    Bimson, W.E.3
  • 11
    • 0028345986 scopus 로고
    • Exercise-induced changes in oxygen saturation in the calf muscles of elderly subjects with peripheral vascular disease
    • McCully K. K., Halber C., Posner J. D. Exercise-induced changes in oxygen saturation in the calf muscles of elderly subjects with peripheral vascular disease. J Gerontol: 1994; 49 3 B128 B134
    • (1994) J Gerontol , vol.49 , Issue.3 , pp. B128-B134
    • McCully, K.K.1    Halber, C.2    Posner, J.D.3
  • 12
    • 0035168016 scopus 로고    scopus 로고
    • A prospective comparison of pedal ergometry with conventional treadmill testing in the investigation of lower extremity pain
    • Manning B. J., McGreal G., Crowley H., Redmond H. P., O'Donnell J. A. A prospective comparison of pedal ergometry with conventional treadmill testing in the investigation of lower extremity pain. Ir J Med Sci: 2001; 170 3 169 171
    • (2001) Ir J Med Sci , vol.170 , Issue.3 , pp. 169-171
    • Manning, B.J.1    McGreal, G.2    Crowley, H.3    Redmond, H.P.4    O'Donnell, J.A.5
  • 13
    • 0025210494 scopus 로고
    • A simple calf muscle ergometer for use in a standard whole-body MR scanner
    • Quistorff B., Nielsen S., Thomsen C., Jensen K. E., Henriksen O. A simple calf muscle ergometer for use in a standard whole-body MR scanner. Magn Reson Med: 1990; 13 3 444 449
    • (1990) Magn Reson Med , vol.13 , Issue.3 , pp. 444-449
    • Quistorff, B.1    Nielsen, S.2    Thomsen, C.3    Jensen, K.E.4    Henriksen, O.5
  • 15
    • 83655191542 scopus 로고    scopus 로고
    • Local control of skeletal muscle blood flow during exercise: Influence of available oxygen
    • Casey D. P., Joyner M. J. Local control of skeletal muscle blood flow during exercise: influence of available oxygen. J Appl Physiol (1985): 2011; 111 6 1527 1538
    • (2011) J Appl Physiol (1985) , vol.111 , Issue.6 , pp. 1527-1538
    • Casey, D.P.1    Joyner, M.J.2
  • 16
    • 0034910962 scopus 로고    scopus 로고
    • Femoral artery wall thickness and stiffness in evaluation of peripheral vascular disease in type 2 diabetes mellitus
    • Taniwaki H., Shoji T., Emoto M., et al. Femoral artery wall thickness and stiffness in evaluation of peripheral vascular disease in type 2 diabetes mellitus. Atherosclerosis: 2001; 158 1 207 214
    • (2001) Atherosclerosis , vol.158 , Issue.1 , pp. 207-214
    • Taniwaki, H.1    Shoji, T.2    Emoto, M.3
  • 17
    • 77950302173 scopus 로고    scopus 로고
    • Variability and short-term determinants of walking capacity in patients with intermittent claudication
    • Le Faucheur A., Noury-Desvaux B., Mahé G., et al. Variability and short-term determinants of walking capacity in patients with intermittent claudication. J Vasc Surg: 2010; 51 4 886 892
    • (2010) J Vasc Surg , vol.51 , Issue.4 , pp. 886-892
    • Le Faucheur, A.1    Noury-Desvaux, B.2    Mahé, G.3
  • 18
    • 34247639142 scopus 로고    scopus 로고
    • Skeletal muscle StO2 kinetics are slowed during low work rate calf exercise in peripheral arterial disease
    • Bauer T. A., Brass E. P., Barstow T. J., Hiatt W. R. Skeletal muscle StO2 kinetics are slowed during low work rate calf exercise in peripheral arterial disease. Eur J Appl Physiol: 2007; 100 2 143 151
    • (2007) Eur J Appl Physiol , vol.100 , Issue.2 , pp. 143-151
    • Bauer, T.A.1    Brass, E.P.2    Barstow, T.J.3    Hiatt, W.R.4
  • 19
    • 84857657853 scopus 로고    scopus 로고
    • Orthostatic leg blood volume changes assessed by near-infrared spectroscopy
    • Truijen J., Kim Y. S., Krediet C. T., et al. Orthostatic leg blood volume changes assessed by near-infrared spectroscopy. Exp Physiol: 2012; 97 3 353 361
    • (2012) Exp Physiol , vol.97 , Issue.3 , pp. 353-361
    • Truijen, J.1    Kim, Y.S.2    Krediet, C.T.3
  • 20
    • 0031849485 scopus 로고    scopus 로고
    • Reliability of assessment tools in rehabilitation: An illustration of appropriate statistical analyses
    • Rankin G., Stokes M. Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil: 1998; 12 3 187 199
    • (1998) Clin Rehabil , vol.12 , Issue.3 , pp. 187-199
    • Rankin, G.1    Stokes, M.2
  • 21
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • Bland J. M., Altman D. G. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat: 2007; 17 4 571 582
    • (2007) J Biopharm Stat , vol.17 , Issue.4 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 35448990402 scopus 로고    scopus 로고
    • Evidence-based medicine (EBM) in practice: Agreement between observers rating esophageal varices: How to cope with chance
    • Sierra F., Cárdenas A. Evidence-based medicine (EBM) in practice: agreement between observers rating esophageal varices: how to cope with chance? Am J Gastroenterol: 2007; 102 11 2363 2366
    • (2007) Am J Gastroenterol , vol.102 , Issue.11 , pp. 2363-2366
    • Sierra, F.1    Cárdenas, A.2
  • 23
    • 20544472012 scopus 로고    scopus 로고
    • ATP economy of force maintenance in human tibialis anterior muscle
    • Nakagawa Y., Ratkevicius A., Mizuno M., Quistorff B. ATP economy of force maintenance in human tibialis anterior muscle. Med Sci Sports Exerc: 2005; 37 6 937 943
    • (2005) Med Sci Sports Exerc , vol.37 , Issue.6 , pp. 937-943
    • Nakagawa, Y.1    Ratkevicius, A.2    Mizuno, M.3    Quistorff, B.4
  • 24
    • 18844451291 scopus 로고    scopus 로고
    • Skeletal muscle phenotype is associated with exercise tolerance in patients with peripheral arterial disease
    • Askew C. D., Green S., Walker P. J., et al. Skeletal muscle phenotype is associated with exercise tolerance in patients with peripheral arterial disease. J Vasc Surg: 2005; 41 5 802 807
    • (2005) J Vasc Surg , vol.41 , Issue.5 , pp. 802-807
    • Askew, C.D.1    Green, S.2    Walker, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.