Clinical implementation and failure mode and effects analysis of HDR skin brachytherapy using Valencia and Leipzig surface applicators

Author keywords

Brachytherapy; Failure modes and effects analysis; FMEA; HDR; Leipzig; Quality; Safety; Skin; Surface applicator; Valencia

Indexed keywords

ANALYTICAL PARAMETERS; ARTICLE; BRACHYTHERAPY; CHECKLIST; DOSE CALCULATION; ELECTRONIC MEDICAL RECORD; FAILURE MODES AND EFFECTS ANALYSIS; HIGH DOSE RATE SKIN BRACHYTHERAPY; HUMAN; MEDICAL ERROR; ONCOLOGY; PATIENT CODING; PEER REVIEW; PRESCRIPTION; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RADIATION DOSE FRACTIONATION; RADIATION ONCOLOGIST; RADIOTHERAPY EQUIPMENT; RISK FACTOR; SCORING SYSTEM; TREATMENT PLANNING; VALENCIA AND LEIPZIG SURFACE APPLICATOR; DEVICES; EQUIPMENT DESIGN; SKIN NEOPLASMS; THEORETICAL MODEL; TREATMENT FAILURE;

EID: 84924051638     PISSN: 15384721     EISSN: 18731449     Source Type: Journal    
DOI: 10.1016/j.brachy.2014.11.007     Document Type: Article
Times cited : (36)

References (24)
  • 1
    • 79955146806 scopus 로고    scopus 로고
    • Treatment of facial cutaneous carcinoma with high-dose rate contact brachytherapy with customized molds
    • Maronas M., Guinot J.L., Arribas L., et al. Treatment of facial cutaneous carcinoma with high-dose rate contact brachytherapy with customized molds. Brachytherapy 2011, 10:221-227.
    • (2011) Brachytherapy , vol.10 , pp. 221-227
    • Maronas, M.1    Guinot, J.L.2    Arribas, L.3
  • 2
    • 84883555174 scopus 로고    scopus 로고
    • Complete response of endemic Kaposi sarcoma lesions with high-dose-rate brachytherapy: Treatment method, results, and toxicity using skin surface applicators
    • Kasper M., Richter S., Warren N., et al. Complete response of endemic Kaposi sarcoma lesions with high-dose-rate brachytherapy: Treatment method, results, and toxicity using skin surface applicators. Brachytherapy 2013, 12:495-499.
    • (2013) Brachytherapy , vol.12 , pp. 495-499
    • Kasper, M.1    Richter, S.2    Warren, N.3
  • 4
    • 84864999396 scopus 로고    scopus 로고
    • Ultrasound in dermatology: Principles and applications
    • Kleinerman R., Whang T., Bard R., et al. Ultrasound in dermatology: Principles and applications. J Am Acad Dermatol 2012, 67:478-487.
    • (2012) J Am Acad Dermatol , vol.67 , pp. 478-487
    • Kleinerman, R.1    Whang, T.2    Bard, R.3
  • 8
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Report of AAPM Radiation Therapy Committee Task Group 43
    • Nath R., Anderson L., Luxton G., et al. Dosimetry of interstitial brachytherapy sources: Report of AAPM Radiation Therapy Committee Task Group 43. Med Phys 1995, 22:209-234.
    • (1995) Med Phys , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.2    Luxton, G.3
  • 9
    • 84893132514 scopus 로고    scopus 로고
    • Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations
    • Gramerp D., Perez-Calatayud J., Vijande J., et al. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations. Med Phys 2014, 41:021703/8.
    • (2014) Med Phys , vol.41 , pp. 021703-021708
    • Gramerp, D.1    Perez-Calatayud, J.2    Vijande, J.3
  • 10
    • 66449095918 scopus 로고    scopus 로고
    • An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions
    • Rivard M.J., Melhus C.S., Granero D., et al. An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions. Med Phys 2009, 36:1968-1975.
    • (2009) Med Phys , vol.36 , pp. 1968-1975
    • Rivard, M.J.1    Melhus, C.S.2    Granero, D.3
  • 12
    • 84861625144 scopus 로고    scopus 로고
    • Reply to "Comment on 'Correspondence factor for Nucletron surface applicators'"
    • Granero D., Perez-Calatayud J., Ballester F. Reply to "Comment on 'Correspondence factor for Nucletron surface applicators'". Med Phys 2012, 39:2310-2311.
    • (2012) Med Phys , vol.39 , pp. 2310-2311
    • Granero, D.1    Perez-Calatayud, J.2    Ballester, F.3
  • 13
    • 0031956336 scopus 로고    scopus 로고
    • High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59
    • Kubo H.D., Glasgow G.P., Pethel T.D., et al. High dose-rate brachytherapy treatment delivery: Report of the AAPM Radiation Therapy Committee Task Group No. 59. Med Phys 1998, 25:375-403.
    • (1998) Med Phys , vol.25 , pp. 375-403
    • Kubo, H.D.1    Glasgow, G.P.2    Pethel, T.D.3
  • 14
    • 0030801752 scopus 로고    scopus 로고
    • Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56
    • Nath R., Anderson L.L., Meli J.A., et al. Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 56. Med Phys 1997, 24:1557-1595.
    • (1997) Med Phys , vol.24 , pp. 1557-1595
    • Nath, R.1    Anderson, L.L.2    Meli, J.A.3
  • 15
    • 84855827151 scopus 로고    scopus 로고
    • Preventing accidental exposures from new external beam radiation therapy technologies. ICRP Publication 112
    • ICRP. Preventing accidental exposures from new external beam radiation therapy technologies. ICRP Publication 112. Ann ICRP 2009, 39:1-86. ICRP.
    • (2009) Ann ICRP , vol.39 , pp. 1-86
  • 16
    • 41749098585 scopus 로고    scopus 로고
    • A method for evaluating quality assurance needs in radiation therapy
    • Huq M.S., Fraass B.A., Dunscombe P.B., et al. A method for evaluating quality assurance needs in radiation therapy. Int J Radiat Oncol Biol Phys 2008, 71:S170-S173.
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. S170-S173
    • Huq, M.S.1    Fraass, B.A.2    Dunscombe, P.B.3
  • 17
    • 67049107499 scopus 로고    scopus 로고
    • Evaluation of safety in a radiation oncology setting using failure mode and effects analysis
    • Ford E.C., Gaudette R., Myers L., et al. Evaluation of safety in a radiation oncology setting using failure mode and effects analysis. Int J Radiat Oncol Biol Phys 2009, 74:852-858.
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 852-858
    • Ford, E.C.1    Gaudette, R.2    Myers, L.3
  • 18
    • 84879463272 scopus 로고    scopus 로고
    • Failure modes and effects analysis applied to HDR brachytherapy treatment planning
    • Wilkinson D.A., Kora M.D. Failure modes and effects analysis applied to HDR brachytherapy treatment planning. Brachytherapy 2013, 12:382-386.
    • (2013) Brachytherapy , vol.12 , pp. 382-386
    • Wilkinson, D.A.1    Kora, M.D.2
  • 19
    • 84879879600 scopus 로고    scopus 로고
    • Enhancing the role of case-oriented peer review to improve quality and safety in radiation oncology: Executive summary
    • Marks L., Adams R., Pawlicki T., et al. Enhancing the role of case-oriented peer review to improve quality and safety in radiation oncology: Executive summary. Pract Radiat Oncol 2013, 3:149-156.
    • (2013) Pract Radiat Oncol , vol.3 , pp. 149-156
    • Marks, L.1    Adams, R.2    Pawlicki, T.3
  • 20
    • 83455234747 scopus 로고    scopus 로고
    • Improving quality of patient care by improving daily practice in radiation oncology
    • Chera B.S., Jackson M., Manzur L.M., et al. Improving quality of patient care by improving daily practice in radiation oncology. Semin Radiat Oncol 2012, 22:77-85.
    • (2012) Semin Radiat Oncol , vol.22 , pp. 77-85
    • Chera, B.S.1    Jackson, M.2    Manzur, L.M.3
  • 21
    • 33748693969 scopus 로고    scopus 로고
    • SBAR: A shared mental model for improving communication between clinicians
    • Haig K.M., Sutton S., Whittington J. SBAR: A shared mental model for improving communication between clinicians. Jt Comm J Qual Patient Saf 2006, 32:167-175.
    • (2006) Jt Comm J Qual Patient Saf , vol.32 , pp. 167-175
    • Haig, K.M.1    Sutton, S.2    Whittington, J.3
  • 22
    • 33845880922 scopus 로고    scopus 로고
    • An intervention to decrease catheter-related bloodstream infections in the ICU
    • Pronovost P., Needham D., Berenholtz S., et al. An intervention to decrease catheter-related bloodstream infections in the ICU. N Engl J Med 2006, 355:2725-2732.
    • (2006) N Engl J Med , vol.355 , pp. 2725-2732
    • Pronovost, P.1    Needham, D.2    Berenholtz, S.3
  • 23
    • 77951629450 scopus 로고    scopus 로고
    • Clinical review: Checklists-Translating evidence into practice
    • Winters B.D., Gurses A.P., Lehmann H., et al. Clinical review: Checklists-Translating evidence into practice. Crit Care 2009, 13:210.
    • (2009) Crit Care , vol.13 , pp. 210
    • Winters, B.D.1    Gurses, A.P.2    Lehmann, H.3
  • 24
    • 67649913890 scopus 로고    scopus 로고
    • The New Yorker 2007. Available at:. Accessed December5
    • Gawande A. The checklist. The New Yorker 2007. Available at:. Accessed December5, 2014. http://www.newyorker.com/reporting/2007/12/10/071210fa_fact_gawande.
    • (2014) The checklist.
    • Gawande, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.