Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification

Author keywords

[No Author keywords available]

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; CANCER THERAPY; CLINICAL ARTICLE; COMPUTER PROGRAM; DOSE VOLUME HISTOGRAM; DOSIMETER; DOSIMETRY; ESOPHAGUS CANCER; GAMMA INDEX PASSING RATE; HISTOGRAM; HUMAN; MEASUREMENT ERROR; NASOPHARYNX CANCER; QUALITY CONTROL; RADIOLOGICAL PARAMETERS; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY ANALYSIS; VOLUMETRIC MODULATED ARC THERAPY; VOLUMETRY; AGED; COMPARATIVE STUDY; COMPUTER ASSISTED RADIOTHERAPY; FEMALE; GAMMA RADIATION; INTENSITY MODULATED RADIATION THERAPY; MALE; NASOPHARYNGEAL NEOPLASMS; PROCEDURES; RADIATION DOSE; RADIOGRAPHY; RADIOMETRY; THERAPEUTIC USE;

EID: 84923463366     PISSN: 00071285     EISSN: 1748880X     Source Type: Journal    
DOI: 10.1259/bjr.20140577     Document Type: Article
Times cited : (48)

References (24)
  • 1
    • 51049087485 scopus 로고    scopus 로고
    • Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study
    • Bedford JL, Nordmark Hansen V, McNair HA, Aitken AH, Brock JE, Warrington AP, et al. Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study. Acta Oncol 2008; 47: 1438-43. doi: 10.1080/02841860802282778
    • (2008) Acta Oncol , vol.47 , pp. 1438-1443
    • Bedford, J.L.1    Nordmark Hansen, V.2    McNair, H.A.3    Aitken, A.H.4    Brock, J.E.5    Warrington, A.P.6
  • 2
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 2008; 35: 310-17
    • (2008) Med Phys , vol.35 , pp. 310-317
    • Otto, K.1
  • 3
    • 77954289362 scopus 로고    scopus 로고
    • Initial dosimetric evaluation of SmartArc-A novel VMAT treatment planning module implemented in a multi-vendor delivery chain
    • Feygelman V, Zhang G, Stevens C. Initial dosimetric evaluation of SmartArc-A novel VMAT treatment planning module implemented in a multi-vendor delivery chain. J Appl Clin Med Phys 2010; 11: 3169
    • (2010) J Appl Clin Med Phys , vol.11 , pp. 3169
    • Feygelman, V.1    Zhang, G.2    Stevens, C.3
  • 4
    • 79951862797 scopus 로고    scopus 로고
    • Intensity-modulated arc therapy: Principles, technologies and clinical implementation
    • Yu CX, Tang G. Intensity-modulated arc therapy: Principles, technologies and clinical implementation. Phys Med Biol 2011; 56: R31-54. doi: 10.1088/0031-9155/56/5/R01
    • (2011) Phys Med Biol , vol.56 , pp. R31-R54
    • Yu, C.X.1    Tang, G.2
  • 5
    • 34748868975 scopus 로고    scopus 로고
    • Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements
    • Pallotta S, Marazzo L, Bucciolini M. Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements. Med Phys 2007; 34: 3724-31
    • (2007) Med Phys , vol.34 , pp. 3724-3731
    • Pallotta, S.1    Marazzo, L.2    Bucciolini, M.3
  • 6
    • 65449118359 scopus 로고    scopus 로고
    • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    • Létourneau D, Publicover J, Kozelka J, Moseley DJ, Jaffray DA. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy. Med Phys 2009; 36: 1813-21
    • (2009) Med Phys , vol.36 , pp. 1813-1821
    • Létourneau, D.1    Publicover, J.2    Kozelka, J.3    Moseley, D.J.4    Jaffray, D.A.5
  • 7
    • 58149236841 scopus 로고    scopus 로고
    • A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy
    • Gagne IM, Ansbacher W, Zavgorodni S, Popescu C, Beckham WA. A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy. Phys Med Biol 2008; 53: 7167-85. doi: 10.1088/0031-9155/53/24/011
    • (2008) Phys Med Biol , vol.53 , pp. 7167-7185
    • Gagne, I.M.1    Ansbacher, W.2    Zavgorodni, S.3    Popescu, C.4    Beckham, W.A.5
  • 8
    • 60549084371 scopus 로고    scopus 로고
    • Dosimetric verification of RapidArc treatment delivery
    • Korreman S, Medin J, Kjaer-Kristoffersen F. Dosimetric verification of RapidArc treatment delivery. Acta Oncol 2009; 48: 185-91. doi: 10.1080/02841860802287116
    • (2009) Acta Oncol , vol.48 , pp. 185-191
    • Korreman, S.1    Medin, J.2    Kjaer-Kristoffersen, F.3
  • 9
    • 64049093906 scopus 로고    scopus 로고
    • Volumetric intensity-modulated arc therapy vs. Conventional IMRT in head-and-neck cancer: A comparative planning and dosimetric study
    • Verbakel WF, Cuijpers JP, Hoffmans D, Bieker M, Slotman BJ, Senan S. Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: A comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys 2009; 74: 252-9. doi: 10.1016/j.ijrobp.2008.12.033
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 252-259
    • Verbakel, W.F.1    Cuijpers, J.P.2    Hoffmans, D.3    Bieker, M.4    Slotman, B.J.5    Senan, S.6
  • 10
    • 77749252302 scopus 로고    scopus 로고
    • Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: Plan quality, delivery efficiency and accuracy
    • Rao M, Yang W, Chen F, Sheng K, Ye J, Mehta V, et al. Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: Plan quality, delivery efficiency and accuracy. Med Phys 2010; 37: 1350-9
    • (2010) Med Phys , vol.37 , pp. 1350-1359
    • Rao, M.1    Yang, W.2    Chen, F.3    Sheng, K.4    Ye, J.5    Mehta, V.6
  • 11
    • 70350726816 scopus 로고    scopus 로고
    • IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119
    • Ezzell GA, Burmeister JW, Dogan N, LoSasso TJ, Mechalakos JG, Mihailidis D, et al. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009; 36: 5359-73
    • (2009) Med Phys , vol.36 , pp. 5359-5373
    • Ezzell, G.A.1    Burmeister, J.W.2    Dogan, N.3    Losasso, T.J.4    Mechalakos, J.G.5    Mihailidis, D.6
  • 12
    • 84858709089 scopus 로고    scopus 로고
    • Volumetric-modulated arc therapy: Effective and efficient end-to-end patient-specific quality assurance
    • O'Daniel J, Das S, Wu QJ, Yin FF. Volumetric-modulated arc therapy: Effective and efficient end-to-end patient-specific quality assurance. Int J Radiat Oncol Biol Phys 2012; 82: 1567-74. doi: 10.1016/j. ijrobp.2011.01.018
    • (2012) Int J Radiat Oncol Biol Phys , vol.82 , pp. 1567-1574
    • O'Daniel, J.1    Das, S.2    Wu, Q.J.3    Yin, F.F.4
  • 13
    • 70349684823 scopus 로고    scopus 로고
    • Patient-specific quality assurance method for VMAT treatment delivery
    • Schreibmann E, Dhabaan A, Elder E, Fox T. Patient-specific quality assurance method for VMAT treatment delivery. Med Phys 2009; 36: 4530-5
    • (2009) Med Phys , vol.36 , pp. 4530-4535
    • Schreibmann, E.1    Dhabaan, A.2    Elder, E.3    Fox, T.4
  • 14
    • 80053595703 scopus 로고    scopus 로고
    • Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA
    • Zhen H, Nelms BE, Tome WA. Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA. Med Phys 2011; 38: 5477-89. doi: 10.1118/1.3633904
    • (2011) Med Phys , vol.38 , pp. 5477-5489
    • Zhen, H.1    Nelms, B.E.2    Tome, W.A.3
  • 15
    • 84870943985 scopus 로고    scopus 로고
    • Pretreatment patientspecific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogram
    • Stasi M, Bresciani S, Miranti A, Maggio A, Sapino V, Gabriele P. Pretreatment patientspecific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogram. Med Phys 2012; 39: 7626-34. doi: 10.1118/1.4767763
    • (2012) Med Phys , vol.39 , pp. 7626-7634
    • Stasi, M.1    Bresciani, S.2    Miranti, A.3    Maggio, A.4    Sapino, V.5    Gabriele, P.6
  • 16
    • 84887071904 scopus 로고    scopus 로고
    • Comparison of whole field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer
    • Jin X, Yi J, Zhou Y, Yan H, Han C, Xie C. Comparison of whole field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer. Med Dosim 2013; 38: 418-23. doi: 10.1016/j. meddos.2013.05.004
    • (2013) Med Dosim , vol.38 , pp. 418-423
    • Jin, X.1    Yi, J.2    Zhou, Y.3    Yan, H.4    Han, C.5    Xie, C.6
  • 17
    • 84884135543 scopus 로고    scopus 로고
    • CRT combined with a sequential VMAT boost in the treatment of upper thoracic esophageal cancer
    • Jin X, Yi J, Zhou Y, Yan H, Han C, Xie C. CRT combined with a sequential VMAT boost in the treatment of upper thoracic esophageal cancer. J Appl Clin Med Phys 2013; 14: 153-61. doi: 10.1120/jacmp. v14i5.4325
    • (2013) J Appl Clin Med Phys , vol.14 , pp. 153-161
    • Jin, X.1    Yi, J.2    Zhou, Y.3    Yan, H.4    Han, C.5    Xie, C.6
  • 18
    • 73649086212 scopus 로고    scopus 로고
    • Calibration of a novel four-dimensional diode array
    • Yan G, Lu B, Kozelka J, Liu C, Li JG. Calibration of a novel four-dimensional diode array. Med Phys 2010; 37: 108-15
    • (2010) Med Phys , vol.37 , pp. 108-115
    • Yan, G.1    Lu, B.2    Kozelka, J.3    Liu, C.4    Li, J.G.5
  • 19
    • 84864229925 scopus 로고    scopus 로고
    • VMAT QA: Measurement-guided 4D dose reconstruction on a patient
    • Nelms BE, Opp D, Robinson J, Wolf TK, Zhang G, Moros E, et al. VMAT QA: Measurement-guided 4D dose reconstruction on a patient. Med Phys 2012; 39: 4228-38. doi: 10.1118/1.4729709
    • (2012) Med Phys , vol.39 , pp. 4228-4238
    • Nelms, B.E.1    Opp, D.2    Robinson, J.3    Wolf, T.K.4    Zhang, G.5    Moros, E.6
  • 20
    • 84923402909 scopus 로고    scopus 로고
    • U.S. patent no. 7945022.
    • Nelms BE, Simon WE. U.S. patent no. 7945022. 2011
    • (2011)
    • Nelms, B.E.1    Simon, W.E.2
  • 21
    • 80855128877 scopus 로고    scopus 로고
    • Statistical variability and confidence intervals for planar dose QA pass rates
    • Bailey DW, Nelms BE, Attwood K, Kumaraswamy L, Podgorsak M. Statistical variability and confidence intervals for planar dose QA pass rates. Med Phys 2011; 38: 6053-64. doi: 10.1118/1.3651695
    • (2011) Med Phys , vol.38 , pp. 6053-6064
    • Bailey, D.W.1    Nelms, B.E.2    Attwood, K.3    Kumaraswamy, L.4    Podgorsak, M.5
  • 22
    • 79551672470 scopus 로고    scopus 로고
    • Per-beam, plannar IMRT QA passing rates do not predict clinically relevant patient dose errors
    • Nelms BE, Zhen H, Tomé WA. Per-beam, plannar IMRT QA passing rates do not predict clinically relevant patient dose errors. Med Phys 2011; 38: 1037-44
    • (2011) Med Phys , vol.38 , pp. 1037-1044
    • Nelms, B.E.1    Zhen, H.2    Tomé, W.A.3
  • 23
    • 84883386579 scopus 로고    scopus 로고
    • Experimental verification of the planned dose perturbation algorithm in an anthropomorphic phantom
    • Feygelman V, Opp D, Zhang G, Stevens C, Nelms B. Experimental verification of the planned dose perturbation algorithm in an anthropomorphic phantom. J Phys Conf Ser 2013; 444: 012047
    • (2013) J Phys Conf ser , vol.444 , pp. 012047
    • Feygelman, V.1    Opp, D.2    Zhang, G.3    Stevens, C.4    Nelms, B.5
  • 24
    • 84864701518 scopus 로고    scopus 로고
    • 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification
    • Carrasco P, Jornet N, Latorre A, Eudaldo T, Ruiz A. Ribas M. 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification. Med Phys 2012; 39: 5040-9. doi: 10.1118/1.4736949
    • (2012) Med Phys , vol.39 , pp. 5040-5049
    • Carrasco, P.1    Jornet, N.2    Latorre, A.3    Eudaldo, T.4    Ruiz, A.5    Ribas, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.