메뉴 건너뛰기




Volumn 36, Issue 2, 2015, Pages 192-197

Evaluation of a pulsed xenon ultraviolet disinfection system for reduction of healthcare-associated pathogens in hospital rooms

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BACTERIAL SPORE; COLONY FORMING UNIT; DISINFECTION SYSTEM; ENVIRONMENTAL EXPOSURE; METHICILLIN RESISTANT STAPHYLOCOCCUS AUREUS; MICROBIAL CONTAMINATION; NONHUMAN; PATHOGEN CLEARANCE; PATHOGEN LOAD; PEPTOCLOSTRIDIUM DIFFICILE; PULSED XENON ULTRAVIOLET DISINFECTION SYSTEM; RECOVERY ROOM; ULTRAVIOLET IRRADIATION; VANCOMYCIN RESISTANT ENTEROCOCCUS; BACTERIAL COUNT; CROSS INFECTION; DISINFECTION; EVALUATION STUDY; FOMITE; HEALTH CARE FACILITY; MICROBIOLOGY; PROCEDURES; RADIATION RESPONSE; TIME; ULTRAVIOLET RADIATION;

EID: 84922702269     PISSN: 0899823X     EISSN: 15596834     Source Type: Journal    
DOI: 10.1017/ice.2014.36     Document Type: Article
Times cited : (110)

References (22)
  • 2
    • 0018092382 scopus 로고
    • Inactivation of Bacillus thuringiensis spores by ultraviolet and visible light
    • Griego VM, Spence KD. Inactivation of Bacillus thuringiensis spores by ultraviolet and visible light. Appl Env Microbiol 1977;35:906-910.
    • (1977) Appl Env Microbiol , vol.35 , pp. 906-910
    • Griego, V.M.1    Spence, K.D.2
  • 3
    • 84979943116 scopus 로고
    • Action of ultraviolet light on spores and vegetative forms of Bacillus megatherium sp
    • Hercik F. Action of ultraviolet light on spores and vegetative forms of Bacillus megatherium sp. J Gen Physiol 1936;20:589-594.
    • (1936) J Gen Physiol , vol.20 , pp. 589-594
    • Hercik, F.1
  • 4
    • 33744733251 scopus 로고    scopus 로고
    • Spores of Bacillus subtilis: Their resistance to and killing by radiation, heat and chemicals
    • Setlow P. Spores of Bacillus subtilis: their resistance to and killing by radiation, heat and chemicals. J Appl Microbiol 2006;101:514-525.
    • (2006) J Appl Microbiol , vol.101 , pp. 514-525
    • Setlow, P.1
  • 5
    • 0035170878 scopus 로고    scopus 로고
    • Resistance of spores of Bacillus species to ultraviolet light
    • Setlow P. Resistance of spores of Bacillus species to ultraviolet light. Environ Mol Mutagen 2001;38:97-104.
    • (2001) Environ Mol Mutagen , vol.38 , pp. 97-104
    • Setlow, P.1
  • 7
    • 77955118101 scopus 로고    scopus 로고
    • High-dose ultra-violet C light inactivates spores of Bacillus subtilis var. Niger and Bacillus anthracis Sterne on non-reflective surfaces
    • Owens MU, Deal DR, Shoemaker MO, et al. High-dose ultra-violet C light inactivates spores of Bacillus subtilis var. niger and Bacillus anthracis Sterne on non-reflective surfaces. Appl Biosafety 2005;10:240-247.
    • (2005) Appl Biosafety , vol.10 , pp. 240-247
    • Owens, M.U.1    Deal, D.R.2    Shoemaker, M.O.3
  • 8
    • 84899487894 scopus 로고    scopus 로고
    • Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus
    • Jinadatha C, Quezada R, Huber TW, Williams JB, Zeber JE, Copeland LA. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus. BMC Infect Dis 2014;14:187.
    • (2014) BMC Infect Dis , vol.14 , pp. 187
    • Jinadatha, C.1    Quezada, R.2    Huber, T.W.3    Williams, J.B.4    Zeber, J.E.5    Copeland, L.A.6
  • 9
    • 84880917363 scopus 로고    scopus 로고
    • The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital
    • Levin J, Riley LS, Parrish C, English D, Ahn S. The effect of portable pulsed xenon ultraviolet light after terminal cleaning on hospital-associated Clostridium difficile infection in a community hospital. Am J Infect Control 2013;41:746-748.
    • (2013) Am J Infect Control , vol.41 , pp. 746-748
    • Levin, J.1    Riley, L.S.2    Parrish, C.3    English, D.4    Ahn, S.5
  • 10
  • 11
    • 79952383241 scopus 로고    scopus 로고
    • Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on hospital operations and microbial reduction
    • Stibich M, Stachowiak J, Tanner B, et al. Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on hospital operations and microbial reduction. Infect Control Hosp Epidemiol 2011;32:286-288.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 286-288
    • Stibich, M.1    Stachowiak, J.2    Tanner, B.3
  • 12
    • 84864574497 scopus 로고    scopus 로고
    • A comparative study of the bactericidal activity and daily disinfection housekeeping surfaces by a new portable pulsed UV radiation device
    • Umezawa K, Asai S, Inokuchi S, Miyachi H. A comparative study of the bactericidal activity and daily disinfection housekeeping surfaces by a new portable pulsed UV radiation device. Curr Microbiol 2012;64:581-587.
    • (2012) Curr Microbiol , vol.64 , pp. 581-587
    • Umezawa, K.1    Asai, S.2    Inokuchi, S.3    Miyachi, H.4
  • 13
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic MM, Cadnum JL, Pultz MJ, Donskey CJ. Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010;10:197.
    • (2010) BMC Infect Dis , vol.10 , pp. 197
    • Nerandzic, M.M.1    Cadnum, J.L.2    Pultz, M.J.3    Donskey, C.J.4
  • 14
    • 41549142775 scopus 로고    scopus 로고
    • Bile salts and glycine as cogerminants for Clostridium difficile spores
    • Sorg JA, Sonenshein AL. Bile salts and glycine as cogerminants for Clostridium difficile spores. J Bacteriol 2008;190(7):2505-2512.
    • (2008) J Bacteriol , vol.190 , Issue.7 , pp. 2505-2512
    • Sorg, J.A.1    Sonenshein, A.L.2
  • 15
    • 60849085177 scopus 로고    scopus 로고
    • Effective and reduced-cost modified selective medium for isolation of Clostridium difficile
    • Nerandzic MM, Donskey CJ. Effective and reduced-cost modified selective medium for isolation of Clostridium difficile. J Clin Microbiol 2009;47(2):397-400.
    • (2009) J Clin Microbiol , vol.47 , Issue.2 , pp. 397-400
    • Nerandzic, M.M.1    Donskey, C.J.2
  • 17
    • 84861014016 scopus 로고    scopus 로고
    • Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens
    • Nerandzic MM, Cadnum JL, Eckart KE, Donskey CJ. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis 2012;12:120.
    • (2012) BMC Infect Dis , vol.12 , pp. 120
    • Nerandzic, M.M.1    Cadnum, J.L.2    Eckart, K.E.3    Donskey, C.J.4
  • 18
    • 84907457153 scopus 로고    scopus 로고
    • Sorting through the wealth of options: Comparative evaluation of 2 ultraviolet disinfection systems
    • Nerandzic MM, Fisher CW, Donskey CJ. Sorting through the wealth of options: Comparative evaluation of 2 ultraviolet disinfection systems. PLOS ONE, 9:e107444.
    • PLOS ONE , vol.9
    • Nerandzic, M.M.1    Fisher, C.W.2    Donskey, C.J.3
  • 19
    • 84884187554 scopus 로고    scopus 로고
    • Does organic material on hospital surfaces reduce the effectiveness of hypochlorite and UV radiation for disinfection of Clostridium difficile?
    • Zhang A, Nerandzic MM, Kundrapu S, Donskey CJ. Does organic material on hospital surfaces reduce the effectiveness of hypochlorite and UV radiation for disinfection of Clostridium difficile? Infect Control Hosp Epidemiol 2013;34:1106-1108.
    • (2013) Infect Control Hosp Epidemiol , vol.34 , pp. 1106-1108
    • Zhang, A.1    Nerandzic, M.M.2    Kundrapu, S.3    Donskey, C.J.4
  • 20
    • 67651089832 scopus 로고    scopus 로고
    • Comparison of the efficacy of a hydrogen peroxide dry-mist disinfection system and sodium hypochlorite solution for reduction of Clostridium difficile spores
    • Barbut F, Menuet D, Verachten M, Girou E. Comparison of the efficacy of a hydrogen peroxide dry-mist disinfection system and sodium hypochlorite solution for reduction of Clostridium difficile spores. Infect Control Hosp Epidemiol 2009;30:507-514.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 507-514
    • Barbut, F.1    Menuet, D.2    Verachten, M.3    Girou, E.4
  • 21
    • 50949120269 scopus 로고    scopus 로고
    • Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting
    • Boyce JM, Havill NL, Otter JA, et al. Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting. Infect Control Hosp Epidemiol 2008;29:723-729.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 723-729
    • Boyce, J.M.1    Havill, N.L.2    Otter, J.A.3
  • 22
    • 84901018597 scopus 로고    scopus 로고
    • Implementation and impact of ultraviolet environmental disinfection in an acute care setting
    • Haas JP, Menz J, Dusza S, Montecalvo MA. Implementation and impact of ultraviolet environmental disinfection in an acute care setting. Am J Infect Control 2014;42:586-590.
    • (2014) Am J Infect Control , vol.42 , pp. 586-590
    • Haas, J.P.1    Menz, J.2    Dusza, S.3    Montecalvo, M.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.