메뉴 건너뛰기




Volumn 45, Issue 12, 2014, Pages 1885-1888

The role of post-operative radiographs in predicting risk of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures - A case control study

Author keywords

Distal radius; Flexor pollicis longus; Fracture; Rupture; Tendon; Volar plating

Indexed keywords

ARTICLE; CASE CONTROL STUDY; CLINICAL ARTICLE; CONTROLLED STUDY; FLEXOR POLLICIS LONGUS RUPTURE; FRACTURE REDUCTION; HAND RADIOGRAPHY; HUMAN; MUSCULOSKELETAL SYSTEM PARAMETERS; PLATE DISTANCE; PRIORITY JOURNAL; RADIAL TILT; RADIUS FRACTURE; TENDON RUPTURE; VOLAR PLATE FIXATION; ADVERSE EFFECTS; FRACTURE HEALING; INJURIES; OSTEOSYNTHESIS; POSTOPERATIVE PERIOD; RADIOGRAPHY; RADIUS FRACTURES; RUPTURE; TENDON INJURIES; TREATMENT OUTCOME; VOLAR PLATE;

EID: 84922605743     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2014.05.035     Document Type: Article
Times cited : (18)

References (15)
  • 1
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking plate system
    • Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking plate system. Int Orthop 2003;27(1): 1-6.
    • (2003) Int Orthop , vol.27 , Issue.1 , pp. 1-6
    • Drobetz, H.1    Kutscha-Lissberg, E.2
  • 2
    • 33845734224 scopus 로고    scopus 로고
    • Delayed rupture of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • Al-Rashid M, Theivendran K, Craigen MA. Delayed rupture of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br 2006;88(12): 1610-2.
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.12 , pp. 1610-162
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.3
  • 3
    • 0031951657 scopus 로고    scopus 로고
    • Rupture of flexor pollicis longus tendon: A complica-Tion of volar plating of the distal radius
    • Bell JSP, Wollstein R. Rupture of flexor pollicis longus tendon: A complica-Tion of volar plating of the distal radius. J Bone Joint Surg Br 1998;80(2): 225-6.
    • (1998) J Bone Joint Surg Br , vol.80 , Issue.2 , pp. 225-226
    • Bell, J.S.P.1    Wollstein, R.2
  • 4
    • 69049095148 scopus 로고    scopus 로고
    • Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius
    • Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 2009;34(4): 471-4. http://dx.doi.org/10.1177/1753193408100964.
    • (2009) J Hand Surg Eur , vol.34 , Issue.4 , pp. 471-474
    • Casaletto, J.A.1    Machin, D.2    Leung, R.3    Brown, D.J.4
  • 5
    • 84866728303 scopus 로고    scopus 로고
    • Incidence and clinical outcomes of tendon rupture following distal radius fracture
    • White BD, Nydick JA, Karsky D, Williams BD, Hess AV, Stone JD. Incidence and clinical outcomes of tendon rupture following distal radius fracture. J Hand Surg 2012;37(10): 2035-40.
    • (2012) J Hand Surg , vol.37 , Issue.10 , pp. 2035-2040
    • White, B.D.1    Nydick, J.A.2    Karsky, D.3    Williams, B.D.4    Hess, A.V.5    Stone, J.D.6
  • 6
    • 84858392521 scopus 로고    scopus 로고
    • Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures
    • Tada K, Ikeda K, Shigemoto K, Suganuma S, Tsuchiya H. Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand Surg 2011;16(3): 271-5.
    • (2011) Hand Surg , vol.16 , Issue.3 , pp. 271-275
    • Tada, K.1    Ikeda, K.2    Shigemoto, K.3    Suganuma, S.4    Tsuchiya, H.5
  • 7
    • 40549098158 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius
    • Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ) 2007;36(12): 669-70.
    • (2007) Am J Orthop (Belle Mead NJ) , vol.36 , Issue.12 , pp. 669-670
    • Duncan, S.F.1    Weiland, A.J.2
  • 8
    • 36448985125 scopus 로고    scopus 로고
    • Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius
    • Koo SC, Ho ST. Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius. Hand Surg 2006;11(1-2): 67-70.
    • (2006) Hand Surg , vol.11 , Issue.1-2 , pp. 67-70
    • Koo, S.C.1    Ho, S.T.2
  • 9
    • 79951932617 scopus 로고    scopus 로고
    • Volar locking plate implant prominence and flexor tendon rupture
    • Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 2011;93(4): 328-35. http://dx.doi.org/10.2106/JBJS.J.00193.
    • (2011) J Bone Joint Surg Am , vol.93 , Issue.4 , pp. 328-335
    • Soong, M.1    Earp, B.E.2    Bishop, G.3    Leung, A.4    Blazar, P.5
  • 10
    • 84878243996 scopus 로고    scopus 로고
    • Volar plate position and flexor tendon rupture following distal radius fracture fixation
    • Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am 2013;38(6): 1091-6. http://dx.doi.org/10.1016/j.jhsa. 03.011.
    • (2013) J Hand Surg Am , vol.38 , Issue.6 , pp. 1091-1096
    • Kitay, A.1    Swanstrom, M.2    Schreiber, J.J.3    Carlson, M.G.4    Nguyen, J.T.5    Weiland, A.J.6
  • 11
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 2008;33(2): 164-7. http://dx.doi.org/10.1016/j.jhsa.2007.11.011.
    • (2008) J Hand Surg Am , vol.33 , Issue.2 , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2
  • 12
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TSJ. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report. J Hand Surg Am 1998;23(4): 737-41.
    • (1998) J Hand Surg Am , vol.23 , Issue.4 , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.J.2
  • 13
    • 72449165501 scopus 로고    scopus 로고
    • Flexor tendon problems after volar plate fixation of distal radius fractures
    • Adham MN, Porembski M, Adham C. Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (N Y) 2009;4(4): 406-9. http://dx.doi.org/10.1007/s11552-009-91800.
    • (2009) Hand (N Y) , vol.4 , Issue.4 , pp. 406-409
    • Adham, M.N.1    Porembski, M.2    Adham, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.