메뉴 건너뛰기




Volumn 8, Issue 1, 2015, Pages 47-49

Myocardial T1: The rise of a novel biomarker continues

Author keywords

Cardiac magnetic resonance; Myocardial inflammation; Myocarditis; Native T1

Indexed keywords

BIOLOGICAL MARKER; GADOLINIUM;

EID: 84922586881     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2014.10.002     Document Type: Editorial
Times cited : (6)

References (13)
  • 1
    • 84922579866 scopus 로고    scopus 로고
    • Accessed November 7, 2014
    • Henry Ford. Available at: http://www.quotes.net/quote/6034. Accessed November 7, 2014.
  • 2
    • 0038169798 scopus 로고    scopus 로고
    • Accessed November 7, 2014
    • Oxford Dictionary. Available at: http://www.oxforddictionaries.com/definition/english/biomarker. Accessed November 7, 2014.
    • Oxford Dictionary
  • 4
    • 84922514701 scopus 로고    scopus 로고
    • Native T1 in discrimination of acute and convalescent stages in patients with clinical diagnosis of myocarditis: A proposed diagnostic algorithm using CMR
    • Hinojar R, Foote L, Arroyo Ucar E, et al. Native T1 in discrimination of acute and convalescent stages in patients with clinical diagnosis of myocarditis: a proposed diagnostic algorithm using CMR. J Am Coll Cardiol Img 2015;8:37-46.
    • (2015) J Am Coll Cardiol Img , vol.8 , pp. 37-46
    • Hinojar, R.1    Foote, L.2    Arroyo Ucar, E.3
  • 5
    • 84902086906 scopus 로고    scopus 로고
    • Native T1-mapping detects the location, extent and patterns of acute myocarditis without the need for gadolinium contrast agents
    • Ferreira VM, Piechnik SK, Dall'armellina E, et al. Native T1-mapping detects the location, extent and patterns of acute myocarditis without the need for gadolinium contrast agents. J Cardiovasc Magn Reson 2014;16:36.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 36
    • Ferreira, V.M.1    Piechnik, S.K.2    Dall'armellina, E.3
  • 6
    • 84872229977 scopus 로고    scopus 로고
    • Myocardial tissue characterization using magnetic resonance noncontrast t1 mapping in hypertrophic and dilated cardiomyopathy
    • Dass S, Suttie JJ, Piechnik SK, et al. Myocardial tissue characterization using magnetic resonance noncontrast t1 mapping in hypertrophic and dilated cardiomyopathy. Circ Cardiovasc Imaging 2012;5:726-33.
    • (2012) Circ Cardiovasc Imaging , vol.5 , pp. 726-733
    • Dass, S.1    Suttie, J.J.2    Piechnik, S.K.3
  • 7
    • 84877252985 scopus 로고    scopus 로고
    • Native myocardial T1 mapping by cardiovascular magnetic resonance imaging in subclinical cardiomyopathy in patients with systemic lupus erythematosus
    • Puntmann VO, D'Cruz D, Smith Z, et al. Native myocardial T1 mapping by cardiovascular magnetic resonance imaging in subclinical cardiomyopathy in patients with systemic lupus erythematosus. Circ Cardiovasc Imaging 2013;6: 295-301.
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 295-301
    • Puntmann, V.O.1    D'cruz, D.2    Smith, Z.3
  • 10
    • 84885338673 scopus 로고    scopus 로고
    • Myocardial T1 mapping and extracellular volume quantification: A Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement
    • Moon JC, Messroghli DR, Kellman P, et al. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement. J Cardiovasc Magn Reson 2013;15:92.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 92
    • Moon, J.C.1    Messroghli, D.R.2    Kellman, P.3
  • 11
    • 79952777530 scopus 로고    scopus 로고
    • Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold
    • Piechnik SK, Ferreira VM, Dall'armellina E, et al. Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. J Cardiovasc Magn Reson 2010;12:69.
    • (2010) J Cardiovasc Magn Reson , vol.12 , pp. 69
    • Piechnik, S.K.1    Ferreira, V.M.2    Dall'armellina, E.3
  • 12
    • 84879045917 scopus 로고    scopus 로고
    • Myocardial T1 and T2 mapping at 3 T: Reference values, influencing factors and implications
    • Knobelsdorff-Brenkenhoff von F, Prothmann M, Dieringer MA, et al. Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications. J Cardiovasc Magn Reson 2013;15:53.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 53
    • Von, K.F.1    Prothmann, M.2    Dieringer, M.A.3
  • 13
    • 84891503345 scopus 로고    scopus 로고
    • T1-mapping in the heart: Accuracy and precision
    • Kellman P, Hansen MS. T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson 2014;16:1-20.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 1-20
    • Kellman, P.1    Hansen, M.S.2