메뉴 건너뛰기




Volumn 39, Issue 1, 2015, Pages 77-82

Pulsatile venoarterial perfusion using a novel synchronized cardiac assist device augments coronary artery blood flow during ventricular fibrillation

Author keywords

Cardiogenic shock; Coronary blood flow; Extracorporeal life support system; Extracorporeal membrane oxygenation; Nonpulsatile; Pulsatile; Synchronized cardiac assist

Indexed keywords

BLOOD; BLOOD PRESSURE; FIBER OPTIC SENSORS; HEMODYNAMICS; LEFT VENTRICULAR ASSIST DEVICES; OXYGENATION; RESPIRATORY THERAPY; RESTORATION;

EID: 84922570017     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12413     Document Type: Article
Times cited : (30)

References (18)
  • 1
    • 84898670996 scopus 로고    scopus 로고
    • Trends in incidence, management, and outcomes of cardiogenic shock complicating ST-elevation myocardial infarction in the United States
    • Kolte D, Khera S, Aronow WS, etal. Trends in incidence, management, and outcomes of cardiogenic shock complicating ST-elevation myocardial infarction in the United States. J Am Heart Assoc 2014;3:e000590.
    • (2014) J Am Heart Assoc , vol.3 , pp. e000590
    • Kolte, D.1    Khera, S.2    Aronow, W.S.3
  • 2
    • 84903765006 scopus 로고    scopus 로고
    • Inotropic agents and vasodilator strategies for acute myocardial infarction complicated by cardiogenic shock or low cardiac output syndrome
    • CD009669.
    • Unverzagt S, Wachsmuth L, Hirsch K, etal. Inotropic agents and vasodilator strategies for acute myocardial infarction complicated by cardiogenic shock or low cardiac output syndrome. Cochrane Database Syst Rev 2014;(1):CD009669.
    • (2014) Cochrane Database Syst Rev , Issue.1
    • Unverzagt, S.1    Wachsmuth, L.2    Hirsch, K.3
  • 3
    • 84893339585 scopus 로고    scopus 로고
    • Venous-arterial extracorporeal membrane oxygenation for refractory cardiac arrest: a clinical challenge
    • Lazzeri C, Bernardo P, Sori A, etal. Venous-arterial extracorporeal membrane oxygenation for refractory cardiac arrest: a clinical challenge. Eur Heart J Acute Cardiovasc Care 2013;2:118-126.
    • (2013) Eur Heart J Acute Cardiovasc Care , vol.2 , pp. 118-126
    • Lazzeri, C.1    Bernardo, P.2    Sori, A.3
  • 4
    • 77954366506 scopus 로고    scopus 로고
    • Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults
    • Guan Y, Karkhanis T, Wang S, etal. Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults. Artif Organs 2010;34:529-536.
    • (2010) Artif Organs , vol.34 , pp. 529-536
    • Guan, Y.1    Karkhanis, T.2    Wang, S.3
  • 5
    • 10244260395 scopus 로고    scopus 로고
    • The role of pulsatility in end-organ microcirculation after cardiogenic shock
    • Orime Y, Shiono M, Nakata K, etal. The role of pulsatility in end-organ microcirculation after cardiogenic shock. ASAIO J 1996;42:M724-729.
    • (1996) ASAIO J , vol.42 , pp. M724-M729
    • Orime, Y.1    Shiono, M.2    Nakata, K.3
  • 6
    • 18744363372 scopus 로고    scopus 로고
    • Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support
    • Undar A, Rosenberg G, Myers JL. Major factors in the controversy of pulsatile versus nonpulsatile flow during acute and chronic cardiac support. ASAIO J 2005;51:173-175.
    • (2005) ASAIO J , vol.51 , pp. 173-175
    • Undar, A.1    Rosenberg, G.2    Myers, J.L.3
  • 7
    • 84896827845 scopus 로고    scopus 로고
    • Superior neurologic recovery after 15 minutes of normothermic cardiac arrest using an extracorporeal life support system for optimized blood pressure and flow
    • Trummer G, Foerster K, Buckberg G, etal. Superior neurologic recovery after 15 minutes of normothermic cardiac arrest using an extracorporeal life support system for optimized blood pressure and flow. Perfusion 2014;29:130-138.
    • (2014) Perfusion , vol.29 , pp. 130-138
    • Trummer, G.1    Foerster, K.2    Buckberg, G.3
  • 8
    • 84884816428 scopus 로고    scopus 로고
    • Role of pulsatility in hypothermic reconditioning of porcine kidney grafts by machine perfusion after cold storage
    • Gallinat A, Fox M, Luer B, Efferz P, Paul A, Minor T. Role of pulsatility in hypothermic reconditioning of porcine kidney grafts by machine perfusion after cold storage. Transplantation 2013;96:538-542.
    • (2013) Transplantation , vol.96 , pp. 538-542
    • Gallinat, A.1    Fox, M.2    Luer, B.3    Efferz, P.4    Paul, A.5    Minor, T.6
  • 9
    • 84864322459 scopus 로고    scopus 로고
    • A meta-analysis of renal benefits to pulsatile perfusion in cardiac surgery
    • Sievert A, Sistino J. A meta-analysis of renal benefits to pulsatile perfusion in cardiac surgery. J Extra Corpor Technol 2012;44:10-14.
    • (2012) J Extra Corpor Technol , vol.44 , pp. 10-14
    • Sievert, A.1    Sistino, J.2
  • 10
    • 0036431396 scopus 로고    scopus 로고
    • Pediatric physiologic pulsatile pump enhances cerebral and renal blood flow during and after cardiopulmonary bypass
    • Undar A, Masai T, Beyer EA, Goddard-Finegold J, McGarry MC, Fraser CD Jr. Pediatric physiologic pulsatile pump enhances cerebral and renal blood flow during and after cardiopulmonary bypass. Artif Organs 2002;26:919-923.
    • (2002) Artif Organs , vol.26 , pp. 919-923
    • Undar, A.1    Masai, T.2    Beyer, E.A.3    Goddard-Finegold, J.4    McGarry, M.C.5    Fraser, C.D.6
  • 12
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM, etal. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 1992;85:1899-1911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3
  • 13
    • 84872367905 scopus 로고    scopus 로고
    • Novel pulsatile diagonal pump for pediatric extracorporeal life support system
    • Wang S, Kunselman AR, Undar A. Novel pulsatile diagonal pump for pediatric extracorporeal life support system. Artif Organs 2013;37:37-47.
    • (2013) Artif Organs , vol.37 , pp. 37-47
    • Wang, S.1    Kunselman, A.R.2    Undar, A.3
  • 14
    • 84891896251 scopus 로고    scopus 로고
    • Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system
    • Krawiec C, Wang S, Kunselman AR, Undar A. Impact of pulsatile flow on hemodynamic energy in a Medos Deltastream DP3 pediatric extracorporeal life support system. Artif Organs 2014;38:19-27.
    • (2014) Artif Organs , vol.38 , pp. 19-27
    • Krawiec, C.1    Wang, S.2    Kunselman, A.R.3    Undar, A.4
  • 15
    • 84866733177 scopus 로고    scopus 로고
    • Intraaortic balloon support for myocardial infarction with cardiogenic shock
    • Thiele H, Zeymer U, Neumann FJ, etal. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med 2012;367:1287-1296.
    • (2012) N Engl J Med , vol.367 , pp. 1287-1296
    • Thiele, H.1    Zeymer, U.2    Neumann, F.J.3
  • 16
    • 84893802995 scopus 로고    scopus 로고
    • Intra-aortic balloon counterpulsation-basic principles and clinical evidence
    • de Waha S, Desch S, Eitel I, etal. Intra-aortic balloon counterpulsation-basic principles and clinical evidence. Vascul Pharmacol 2014;60:52-56.
    • (2014) Vascul Pharmacol , vol.60 , pp. 52-56
    • de Waha, S.1    Desch, S.2    Eitel, I.3
  • 17
    • 67649413127 scopus 로고    scopus 로고
    • Intraoperative bypass graft flow in intra-aortic balloon pump-supported patients: differences in arterial and venous sequential conduits
    • Onorati F, Santarpino G, Rubino A, Cristodoro L, Scalas C, Renzulli A. Intraoperative bypass graft flow in intra-aortic balloon pump-supported patients: differences in arterial and venous sequential conduits. J Thorac Cardiovasc Surg 2009;138:54-61.
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 54-61
    • Onorati, F.1    Santarpino, G.2    Rubino, A.3    Cristodoro, L.4    Scalas, C.5    Renzulli, A.6
  • 18
    • 84855955672 scopus 로고    scopus 로고
    • Intra-aortic balloon pumping recruits graft flow reserve by lowering coronary resistances
    • Rubino AS, Onorati F, Scalas C, etal. Intra-aortic balloon pumping recruits graft flow reserve by lowering coronary resistances. Int J Cardiol 2012;154:293-298.
    • (2012) Int J Cardiol , vol.154 , pp. 293-298
    • Rubino, A.S.1    Onorati, F.2    Scalas, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.