메뉴 건너뛰기




Volumn 45, Issue 10, 2014, Pages 1614-1619

The primary determinants of radiation use during fixation of proximal femur fractures

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; BODY MASS; BODY POSITION; FEMALE; FEMUR FRACTURE; FEMUR INTERTROCHANTERIC FRACTURE; FEMUR SUBTROCHANTERIC FRACTURE; FLUOROSCOPY; FRACTURE FIXATION; HOSPITAL PERSONNEL; HUMAN; IONIZING RADIATION; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD REVIEW; ORTHOPEDIC EQUIPMENT; PATIENT POSITIONING; PRIORITY JOURNAL; RETROSPECTIVE STUDY; VERY ELDERLY; BONE SCREW; CLINICAL COMPETENCE; COHORT ANALYSIS; EMERGENCY HEALTH SERVICE; FEMORAL FRACTURES; OCCUPATIONAL EXPOSURE; OSTEOSYNTHESIS; PATIENT CARE; PREVENTION AND CONTROL; PROCEDURES; PROTECTIVE EQUIPMENT; RADIATION DOSE; RADIATION PROTECTION; RADIATION RESPONSE; RADIOGRAPHY; STATISTICS AND NUMERICAL DATA; SUPINE POSITION; TIME; TREATMENT OUTCOME; UTILIZATION;

EID: 84922544699     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2014.05.010     Document Type: Article
Times cited : (16)

References (47)
  • 2
    • 84858123762 scopus 로고    scopus 로고
    • Radiation and cancer risk in atomic-bomb survivors
    • Kodama K, Ozasa K, Okubo T. Radiation and cancer risk in atomic-bomb survivors. J Radiol Prot 2012;32:N51-4.
    • (2012) J Radiol Prot , vol.32 , pp. N51-N54
    • Kodama, K.1    Ozasa, K.2    Okubo, T.3
  • 3
    • 78650017091 scopus 로고    scopus 로고
    • National Council on Radiation Protection and Measurements
    • Report No. 159, Risk to the Thyroid from Ionizing Radiation. (National Council on Radiation Protection and Measurements: 2008).
    • (2008) Risk to the Thyroid from Ionizing Radiation
  • 4
    • 34249039235 scopus 로고    scopus 로고
    • Fluoroscopy-induced chronic radiation skin injury: A disease perhaps often overlooked
    • Frazier TH, Richardson JB, Fabre VC, Callen JP. Fluoroscopy-induced chronic radiation skin injury: A disease perhaps often overlooked. Arch Dermatol 2007;143:637-40.
    • (2007) Arch Dermatol , vol.143 , pp. 637-640
    • Frazier, T.H.1    Richardson, J.B.2    Fabre, V.C.3    Callen, J.P.4
  • 5
    • 2142650712 scopus 로고    scopus 로고
    • Health risks of low dose ionizing radiation in humans: A review
    • Prasad KN, Cole WC, Hasse GM. Health risks of low dose ionizing radiation in humans: A review. Exp Biol Med 2004;229:378-82.
    • (2004) Exp Biol Med , vol.229 , pp. 378-382
    • Prasad, K.N.1    Cole, W.C.2    Hasse, G.M.3
  • 9
    • 0027379367 scopus 로고
    • Epidemiological evidence of effects of small doses of ionizing radiation with a note on the causation of clusters of childhood leukaemia
    • Doll R. Epidemiological evidence of effects of small doses of ionizing radiation with a note on the causation of clusters of childhood leukaemia. J Radiol Prot 1993;13:233-41.
    • (1993) J Radiol Prot , vol.13 , pp. 233-241
    • Doll, R.1
  • 11
    • 14044276800 scopus 로고    scopus 로고
    • Radiation risk is linear with dose at low doses
    • Chadwick K, Leenhouts H. Radiation risk is linear with dose at low doses. Br J Radiol 2005;78:8.
    • (2005) Br J Radiol , vol.78 , pp. 8
    • Chadwick, K.1    Leenhouts, H.2
  • 12
    • 14044274769 scopus 로고    scopus 로고
    • The LNT model provides the best approach for practical implementation of radiation protection
    • Martin CJ. The LNT model provides the best approach for practical implementation of radiation protection. Br J Radiol 2005;78:14-6.
    • (2005) Br J Radiol , vol.78 , pp. 14-16
    • Martin, C.J.1
  • 13
    • 44949184468 scopus 로고    scopus 로고
    • New ICRP recommendations
    • Wrixon AD. New ICRP recommendations. J Radiol Prot 2008;28:161.
    • (2008) J Radiol Prot , vol.28 , pp. 161
    • Wrixon, A.D.1
  • 14
    • 17144455506 scopus 로고    scopus 로고
    • Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery
    • Tremains MR, Georgiadis GM, Dennis MJ. Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery. J Bone Joint Surg (Am) 2001;83-A:674-8.
    • (2001) J Bone Joint Surg (Am) , vol.83 A , pp. 674-678
    • Tremains, M.R.1    Georgiadis, G.M.2    Dennis, M.J.3
  • 15
    • 0033852626 scopus 로고    scopus 로고
    • Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels
    • Crawley MT, Rogers AT. Dose-area product measurements in a range of common orthopaedic procedures and their possible use in establishing local diagnostic reference levels. Br J Radiol 2000;73:740-4.
    • (2000) Br J Radiol , vol.73 , pp. 740-744
    • Crawley, M.T.1    Rogers, A.T.2
  • 16
    • 0032127086 scopus 로고    scopus 로고
    • Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing
    • Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM. Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 1998;29:461-8.
    • (1998) Injury , vol.29 , pp. 461-468
    • Muller, L.P.1    Suffner, J.2    Wenda, K.3    Mohr, W.4    Rommens, P.M.5
  • 18
    • 60549098114 scopus 로고    scopus 로고
    • Cervical spine imaging using standard C-arm fluoroscopy: Patient and surgeon exposure to ionizing radiation
    • Giordano BD, Baumhauer JF, Morgan TL, Rechtine GR. Cervical spine imaging using standard C-arm fluoroscopy: Patient and surgeon exposure to ionizing radiation. Spine 2008;33:1970-6.
    • (2008) Spine , vol.33 , pp. 1970-1976
    • Giordano, B.D.1    Baumhauer, J.F.2    Morgan, T.L.3    Rechtine, G.R.4
  • 19
    • 0018841697 scopus 로고
    • Irradiation of the surgeon during pinning of femoral fractures
    • Giachino AA, Cheng M. Irradiation of the surgeon during pinning of femoral fractures. J Bone Joint Surg Br 1980;62-B:227-9.
    • (1980) J Bone Joint Surg Br , vol.62 B , pp. 227-229
    • Giachino, A.A.1    Cheng, M.2
  • 21
    • 0034667336 scopus 로고    scopus 로고
    • Radiation expo-sure to the spine surgeon during fluoroscopically assisted pedicle screw insertion
    • Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M. Radiation expo-sure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine 2000;25:2637-45.
    • (2000) Spine , vol.25 , pp. 2637-2645
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3    Williams, S.4    Solomito, M.5
  • 22
    • 0343526789 scopus 로고    scopus 로고
    • Radiation exposure during fluo-roscopically assisted pedicle screw insertion in the lumbar spine
    • Jones DP, Robertson PA, Lunt B, Jackson SA. Radiation exposure during fluo-roscopically assisted pedicle screw insertion in the lumbar spine. Spine 2000;25:1538-41.
    • (2000) Spine , vol.25 , pp. 1538-1541
    • Jones, D.P.1    Robertson, P.A.2    Lunt, B.3    Jackson, S.A.4
  • 23
  • 25
    • 77955885262 scopus 로고    scopus 로고
    • Intraoperative C-arm radiation affecting factors and reduction by an intervention program
    • Bar-On E, Weigl DM, Becker T, Katz K, Konen O. Intraoperative C-arm radiation affecting factors and reduction by an intervention program. J Pediatr Orthop 2010;30:320-3.
    • (2010) J Pediatr Orthop , vol.30 , pp. 320-323
    • Bar-On, E.1    Weigl, D.M.2    Becker, T.3    Katz, K.4    Konen, O.5
  • 26
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium-2007. Orthopaedic Trauma As-sociation classification, database and outcomes committee
    • Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, et al. Fracture and dislocation classification compendium-2007. Orthopaedic Trauma As-sociation classification, database and outcomes committee. J Orthop Trauma 2007;21:S1-33.
    • (2007) J Orthop Trauma , vol.21 , pp. S1-S33
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3    Broderick, J.S.4    Creevey, W.5    Decoster, T.A.6
  • 27
    • 0030069896 scopus 로고    scopus 로고
    • Multivariable prognostic models: Issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors
    • Harrell FE, Lee KL, Mark DB. Multivariable prognostic models: Issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors. Stat Med 1996;15:361-87.
    • (1996) Stat Med , vol.15 , pp. 361-387
    • Harrell, F.E.1    Lee, K.L.2    Mark, D.B.3
  • 28
    • 79961087808 scopus 로고    scopus 로고
    • Evidence summary: Systematic review of surgical treatments for geriatric hip fractures
    • Butler M. Evidence summary: Systematic review of surgical treatments for geriatric hip fractures. J Bone Joint Surg (Am) 2011;93:1104.
    • (2011) J Bone Joint Surg (Am) , vol.93 , pp. 1104
    • Butler, M.1
  • 29
    • 11844292534 scopus 로고    scopus 로고
    • Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures
    • Rill L, Butkovich B, Arreola M, Griend RA. Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures. J Bone Joint Surg (Am) 2005;87:13-7.
    • (2005) J Bone Joint Surg (Am) , vol.87 , pp. 13-17
    • Rill, L.1    Butkovich, B.2    Arreola, M.3    Griend, R.A.4
  • 30
    • 28844445002 scopus 로고    scopus 로고
    • Radiation exposure in hand surgery: Mini versus standard C-arm
    • Athwal G, Bueno R, Wolfe S. Radiation exposure in hand surgery: Mini versus standard C-arm. J Hand Surg 2005;30:1310-6.
    • (2005) J Hand Surg , vol.30 , pp. 1310-1316
    • Athwal, G.1    Bueno, R.2    Wolfe, S.3
  • 32
    • 60549084002 scopus 로고    scopus 로고
    • Patient and surgeon radiation exposure: Comparison of standard and mini-C-arm fluoroscopy
    • Giordano BD, Baumhauer JF, Morgan TL, Rechtine 2 GR. Patient and surgeon radiation exposure: Comparison of standard and mini-C-arm fluoroscopy. J Bone Joint Surg Am 2009;91:297-304.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 297-304
    • Giordano, B.D.1    Baumhauer, J.F.2    Morgan, T.L.3    Rechtine, G.R.4
  • 34
    • 0032127740 scopus 로고    scopus 로고
    • Ionising radiation during internal fixation of extracepsular neck of femur fractures
    • Giannoudis PV, McGuigan J, Shaw DL. Ionising radiation during internal fixation of extracepsular neck of femur fractures. Injury 1998;29:469-72.
    • (1998) Injury , vol.29 , pp. 469-472
    • Giannoudis, P.V.1    McGuigan, J.2    Shaw, D.L.3
  • 35
    • 54349129367 scopus 로고    scopus 로고
    • Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience
    • Botchu R, Ravikumar K. Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience. Indian J Orthop 2008;42:471-3.
    • (2008) Indian J Orthop , vol.42 , pp. 471-473
    • Botchu, R.1    Ravikumar, K.2
  • 36
    • 36549044391 scopus 로고    scopus 로고
    • Subtrochanteric femoral fractures
    • Lundy DW. Subtrochanteric femoral fractures. J Am Acad Orthop Surg 2007;15:663-71.
    • (2007) J Am Acad Orthop Surg , vol.15 , pp. 663-671
    • Lundy, D.W.1
  • 37
    • 84877746307 scopus 로고    scopus 로고
    • A monitoring tool for performance improvement in plastic surgery at the individual level
    • Maruthappu M, Duclos A, Orgill D, Carty MJ. A monitoring tool for performance improvement in plastic surgery at the individual level. Plast Reconstr Surg 2013;131:702e-10e.
    • (2013) Plast Reconstr Surg , vol.131 , pp. 702e-710e
    • Maruthappu, M.1    Duclos, A.2    Orgill, D.3    Carty, M.J.4
  • 38
    • 0026699263 scopus 로고
    • Subtrochanteric fractures of the femur: Results of treatment by interlocking nailing
    • Wiss DA, Brien WW. Subtrochanteric fractures of the femur. Results of treatment by interlocking nailing. Clin Orthop Relat Res 1992;283:231-6.
    • (1992) Clin Orthop Relat Res , vol.283 , pp. 231-236
    • Wiss, D.A.1    Brien, W.W.2
  • 40
    • 0030959607 scopus 로고    scopus 로고
    • An approach for the estimation of effective radiation dose at CT in pediatric patients
    • Huda W, Atherton JV, Ware DE, Cumming WA. An approach for the estimation of effective radiation dose at CT in pediatric patients. Radiology 1997;203: 417-22.
    • (1997) Radiology , vol.203 , pp. 417-422
    • Huda, W.1    Atherton, J.V.2    Ware, D.E.3    Cumming, W.A.4
  • 41
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT1
    • Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT1. Radiology 2000;217:430-5.
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 42
    • 0037804787 scopus 로고    scopus 로고
    • Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures
    • Kuon E, Glaser C, Dahm JB. Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures. Br J Radiol 2003;76:406-13.
    • (2003) Br J Radiol , vol.76 , pp. 406-413
    • Kuon, E.1    Glaser, C.2    Dahm, J.B.3
  • 43
    • 33645286249 scopus 로고    scopus 로고
    • Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures
    • Jones HW, Johnston P, Parker M. Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures. Int Orthop (SICO) 2006;30:69-78.
    • (2006) Int Orthop (SICO) , vol.30 , pp. 69-78
    • Jones, H.W.1    Johnston, P.2    Parker, M.3
  • 44
    • 34547481347 scopus 로고    scopus 로고
    • Intertrochanteric hip fractures treated with the trochanteric fixation nail and sliding hip screw
    • Gill JB, Jensen L, Chin PC, Rafiei P, Reddy K, Schutt RCJ. Intertrochanteric hip fractures treated with the trochanteric fixation nail and sliding hip screw. J Surg Orthop Adv 2007;16:62-6.
    • (2007) J Surg Orthop Adv , vol.16 , pp. 62-66
    • Gill, J.B.1    Jensen, L.2    Chin, P.C.3    Rafiei, P.4    Reddy, K.5    Schutt, R.C.J.6
  • 45
    • 33646114311 scopus 로고    scopus 로고
    • The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases
    • discussion 328-9
    • Crawford CH, Malkani AL, Cordray S, Roberts CS, Sligar W. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: A review of 93 cases. J Trauma: Inj Infect Crit Care 2006;60:325-8. discussion 328-9.
    • (2006) J Trauma: Inj Infect Crit Care , vol.60 , pp. 325-328
    • Crawford, C.H.1    Malkani, A.L.2    Cordray, S.3    Roberts, C.S.4    Sligar, W.5
  • 46
    • 77951915036 scopus 로고    scopus 로고
    • A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: A prospective randomized trial
    • Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJ. A comparison of the long gamma nail with the sliding hip screw for the treatment of AO/OTA 31-A2 fractures of the proximal part of the femur: A prospective randomized trial. J Bone Joint Surg Am 2010;92:792-8.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 792-798
    • Barton, T.M.1    Gleeson, R.2    Topliss, C.3    Greenwood, R.4    Harries, W.J.5    Chesser, T.J.6
  • 47
    • 77953577267 scopus 로고    scopus 로고
    • Radiation exposure during in-situ pinning of slipped capital femoral epiphysis hips: Does the patient positioning matter?
    • Mohammed R, Johnson K, Bache E. Radiation exposure during in-situ pinning of slipped capital femoral epiphysis hips: does the patient positioning matter? J Pediatr Orthop B 2010;19:333.
    • (2010) J Pediatr Orthop B , vol.19 , pp. 333
    • Mohammed, R.1    Johnson, K.2    Bache, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.