메뉴 건너뛰기




Volumn 25, Issue 1, 2015, Pages 69-72

The use of s-monovette is effective to reduce the burden of hemolysis in a large urban emergency department

Author keywords

Blood specimen collection; Catheter; Emergency department; Hemolysis; Preanalytical phase

Indexed keywords

ARTICLE; BLOOD COLLECTION TUBE; BLOOD SAMPLING; CONTROLLED STUDY; EMERGENCY WARD; HEMOLYSIS; HUMAN; INTRAVENOUS CATHETER; DEVICES; EMERGENCY HEALTH SERVICE; FEMALE; MALE; PROCEDURES;

EID: 84922496701     PISSN: 13300962     EISSN: None     Source Type: Journal    
DOI: 10.11613/BM.2015.008     Document Type: Article
Times cited : (21)

References (10)
  • 1
    • 80052289159 scopus 로고    scopus 로고
    • Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories
    • Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci 2011;48:143-53. http://dx.doi.org/10.3109/10408363.2011.600228
    • (2011) Crit Rev Clin Lab Sci , vol.48 , pp. 143-153
    • Lippi, G.1    Plebani, M.2    Di Somma, S.3    Cervellin, G.4
  • 2
    • 84878758027 scopus 로고    scopus 로고
    • Critical review and metaanalysis of spurious hemolysis in blood samples collected from intravenous catheters
    • Lippi G, Cervellin G, Mattiuzzi C. Critical review and metaanalysis of spurious hemolysis in blood samples collected from intravenous catheters. Biochem Med 2013;23:193-200. http://dx.doi.org/10.11613/BM.2013.022
    • (2013) Biochem Med , vol.23 , pp. 193-200
    • Lippi, G.1    Cervellin, G.2    Mattiuzzi, C.3
  • 3
    • 84884772522 scopus 로고    scopus 로고
    • A step closer in reducing hemolysis in blood samples collected in the emergency department
    • Kavsak PA. A step closer in reducing hemolysis in blood samples collected in the emergency department. Clin Biochem 2013;46:565. http://dx.doi.org/10.1016/j.clinbiochem. 2013.04.002
    • (2013) Clin Biochem , vol.46 , pp. 565
    • Kavsak, P.A.1
  • 4
    • 84893531970 scopus 로고    scopus 로고
    • Preanalytical phase-an updated review of the current evidence
    • Simundic AM. Preanalytical phase-an updated review of the current evidence. Biochem Med 2014;24:6. http:// dx.doi.org/10.11613/BM.2014.001
    • (2014) Biochem Med , vol.24 , pp. 6
    • Simundic, A.M.1
  • 5
    • 84900335029 scopus 로고    scopus 로고
    • Low volume tubes can be effective to reduce the rate of hemolyzed specimens from the emergency department
    • Giavarina D. Low volume tubes can be effective to reduce the rate of hemolyzed specimens from the emergency department. Clin Biochem 2014;47:688-9. http://dx.doi.org/10.1016/j.clinbiochem.2014.02.019
    • (2014) Clin Biochem , vol.47 , pp. 688-689
    • Giavarina, D.1
  • 6
    • 84893775888 scopus 로고    scopus 로고
    • Low volume tubes are not effective to reduce the rate of hemolyzed specimens from the emergency department
    • Lippi G, Bonelli P, Graiani V, Caleffi C, Cervellin G. Low volume tubes are not effective to reduce the rate of hemolyzed specimens from the emergency department. Clin Biochem 2014;47:227-9. http://dx.doi.org/10.1016/j.clinbiochem. 2013.12.004
    • (2014) Clin Biochem , vol.47 , pp. 227-229
    • Lippi, G.1    Bonelli, P.2    Graiani, V.3    Caleffi, C.4    Cervellin, G.5
  • 7
    • 84885066653 scopus 로고    scopus 로고
    • Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder
    • Lippi G, Avanzini P, Aloe R, Cervellin G. Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder. Biochem Med 2013;23:303-7. http://dx.doi.org/10.11613/BM.2013.036
    • (2013) Biochem Med , vol.23 , pp. 303-307
    • Lippi, G.1    Avanzini, P.2    Aloe, R.3    Cervellin, G.4
  • 8
    • 84884806031 scopus 로고    scopus 로고
    • Prevention of hemolysis in blood samples collected from intravenous catheters
    • Lippi G, Avanzini P, Cervellin G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin Biochem 2013;46:561-4. http://dx.doi.org/10.1016/j.clinbiochem. 2013.01.021
    • (2013) Clin Biochem , vol.46 , pp. 561-564
    • Lippi, G.1    Avanzini, P.2    Cervellin, G.3
  • 9
    • 77953839835 scopus 로고    scopus 로고
    • Hemolysis detection and management of hemolysed specimens
    • Simundic AM, Topic E, Nikolac N, Lippi G. Hemolysis detection and management of hemolysed specimens. Biochem Med 2010;20:154-9. http://dx.doi.org/10.11613/BM.2010.018
    • (2010) Biochem Med , vol.20 , pp. 154-159
    • Simundic, A.M.1    Topic, E.2    Nikolac, N.3    Lippi, G.4
  • 10
    • 77149134702 scopus 로고    scopus 로고
    • Development of a preanalytical errors recording software
    • Lippi G, Bonelli P, Rossi R, Bardi M, Aloe R, Caleffi A, et al. Development of a preanalytical errors recording software. Biochem Med 2010;20:90-5. http://dx.doi.org/10.11613/ BM.2010.011.
    • (2010) Biochem Med , vol.20 , pp. 90-95
    • Lippi, G.1    Bonelli, P.2    Rossi, R.3    Bardi, M.4    Aloe, R.5    Caleffi, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.