-
2
-
-
0037409521
-
Refrigerant charge, pressure drop, and condensation heat transfer in flattened tubes
-
Wilson M.J., Newell T.A., Chato T.A. Refrigerant charge, pressure drop, and condensation heat transfer in flattened tubes. Int. J. Refrig. 2003, 26(4):442-451.
-
(2003)
Int. J. Refrig.
, vol.26
, Issue.4
, pp. 442-451
-
-
Wilson, M.J.1
Newell, T.A.2
Chato, T.A.3
-
3
-
-
65549099049
-
Flow boiling in horizontal flattened tubes: part I-two-phase frictional pressure drop results and model
-
Quibén J.M., Cheng L., da Silva Lima R.J., Thome J.R. Flow boiling in horizontal flattened tubes: part I-two-phase frictional pressure drop results and model. Int. J. Heat Mass Transf. 2009, 52(15-16):3634-3644.
-
(2009)
Int. J. Heat Mass Transf.
, vol.52
, Issue.15-16
, pp. 3634-3644
-
-
Quibén, J.M.1
Cheng, L.2
da Silva Lima, R.J.3
Thome, J.R.4
-
4
-
-
65649117009
-
Flow boiling in horizontal flattened tubes: part II-flow boiling heat transfer results and model
-
Quibén J.M., Cheng L., da Silva Lima R.J., Thome J.R. Flow boiling in horizontal flattened tubes: part II-flow boiling heat transfer results and model. Int. J. Heat Mass Transf. 2009, 52(15-16):3645-3653.
-
(2009)
Int. J. Heat Mass Transf.
, vol.52
, Issue.15-16
, pp. 3645-3653
-
-
Quibén, J.M.1
Cheng, L.2
da Silva Lima, R.J.3
Thome, J.R.4
-
5
-
-
77649179758
-
Performance evaluation of flattened tube in boiling heat transfer enhancement and its effect on pressure drop
-
Nasr M., Akhavan-Behabadi M.A., Marashi S.E. Performance evaluation of flattened tube in boiling heat transfer enhancement and its effect on pressure drop. Int. Commun. Heat Mass Transfer 2010, 37(4):430-436.
-
(2010)
Int. Commun. Heat Mass Transfer
, vol.37
, Issue.4
, pp. 430-436
-
-
Nasr, M.1
Akhavan-Behabadi, M.A.2
Marashi, S.E.3
-
6
-
-
84873570189
-
Condensation heat transfer and pressure drop in flattened smooth tubes having different aspect ratios
-
Kim N.H., Lee E.J., Byun H.W. Condensation heat transfer and pressure drop in flattened smooth tubes having different aspect ratios. Exp. Thermal Fluid Sci. 2013, 46(0):245-253.
-
(2013)
Exp. Thermal Fluid Sci.
, vol.46
, Issue.0
, pp. 245-253
-
-
Kim, N.H.1
Lee, E.J.2
Byun, H.W.3
-
7
-
-
33947547406
-
Of Montreal and Kyoto: a tale of two protocols
-
Sunstein C.R. Of Montreal and Kyoto: a tale of two protocols. Harv. Environ. Law Rev. 2007, 31:1.
-
(2007)
Harv. Environ. Law Rev.
, vol.31
, pp. 1
-
-
Sunstein, C.R.1
-
8
-
-
38249020934
-
The chemistry of stratospheric ozone: its response to natural and anthropogenic influences
-
Kurylo M.J. The chemistry of stratospheric ozone: its response to natural and anthropogenic influences. Int. J. Refrig. 1990, 13(2):62-72.
-
(1990)
Int. J. Refrig.
, vol.13
, Issue.2
, pp. 62-72
-
-
Kurylo, M.J.1
-
9
-
-
0016322177
-
Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone
-
Molina M.J., Rowland F.S. Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone. Nature 1974, 249(5460):810-812.
-
(1974)
Nature
, vol.249
, Issue.5460
, pp. 810-812
-
-
Molina, M.J.1
Rowland, F.S.2
-
11
-
-
0019051775
-
Prediction of horizontal tubeside condensation of pure components using flow regime criteria
-
Breber G., Palen J.W., Taborek J. Prediction of horizontal tubeside condensation of pure components using flow regime criteria. J. Heat Transf. 1980, 102(3):471-476.
-
(1980)
J. Heat Transf.
, vol.102
, Issue.3
, pp. 471-476
-
-
Breber, G.1
Palen, J.W.2
Taborek, J.3
-
12
-
-
77949303106
-
An improved and extended general correlation for heat transfer during condensation in plain tubes
-
Shah M.M. An improved and extended general correlation for heat transfer during condensation in plain tubes. HVAC&R Research 2009, 15(5):889-913.
-
(2009)
HVAC&R Research
, vol.15
, Issue.5
, pp. 889-913
-
-
Shah, M.M.1
-
15
-
-
0015764135
-
Forced convection condensation inside tubes: a heat transfer equation for condenser design
-
Traviss D., Rohsenow W., Baron A. Forced convection condensation inside tubes: a heat transfer equation for condenser design. ASHRAE Trans. 1973, 79(1):157-165.
-
(1973)
ASHRAE Trans.
, vol.79
, Issue.1
, pp. 157-165
-
-
Traviss, D.1
Rohsenow, W.2
Baron, A.3
-
16
-
-
0027190296
-
Pressure Drop During Two-Phase Flow of Pure Refrigerants and Refrigerant-Oil Mixtures in Horizontal Smooth Tubes
-
Souza A.L., Chato J.C., Wattelet J.P., Christofferson B.R. Pressure Drop During Two-Phase Flow of Pure Refrigerants and Refrigerant-Oil Mixtures in Horizontal Smooth Tubes. Proceedings of the 19th National Heat Transfer Conference, Heat Transfer with Alternate Refrigerants, Atlanta, GA, August 8-11, 1993. ASME Papers 1993, 35-41.
-
(1993)
Proceedings of the 19th National Heat Transfer Conference, Heat Transfer with Alternate Refrigerants, Atlanta, GA, August 8-11, 1993. ASME Papers
, pp. 35-41
-
-
Souza, A.L.1
Chato, J.C.2
Wattelet, J.P.3
Christofferson, B.R.4
-
17
-
-
0003212069
-
Improved friction pressure drop correlations for horizontal and vertical two-phase pipe flow
-
Friedel L. Improved friction pressure drop correlations for horizontal and vertical two-phase pipe flow. European two-phase flow group meeting, Paper E 1979.
-
(1979)
European two-phase flow group meeting, Paper E
-
-
Friedel, L.1
-
18
-
-
0024911367
-
Prediction of pressure drop during horizontal annular flow boiling of pure and mixed refrigerants
-
Jung D., Radermacher R. Prediction of pressure drop during horizontal annular flow boiling of pure and mixed refrigerants. Int. J. Heat Mass Transf. 1989, 32(12):2435-2446.
-
(1989)
Int. J. Heat Mass Transf.
, vol.32
, Issue.12
, pp. 2435-2446
-
-
Jung, D.1
Radermacher, R.2
|