메뉴 건너뛰기




Volumn 20, Issue 2, 2015, Pages 248-253

A home-made animal model in comparison with a standard manikin for teaching percutaneous dilatational tracheostomy

Author keywords

Animal model; Manikin; Percutaneous dilatational tracheostomy

Indexed keywords

ADULT; ANATOMIC LANDMARK; ANIMAL TISSUE; ARTICLE; AUDIOVISUAL EQUIPMENT; BRONCHOSCOPE; CONTROLLED STUDY; GUIDE WIRE; GUIDING CATHETER; HUMAN; JOB SATISFACTION; MANIKIN; NEEDLE; NONHUMAN; PHANTOM; PORCINE MODEL; PROSPECTIVE STUDY; RESIDENCY EDUCATION; RESIDENT; SKIN TURGOR; TRACHEOSTOMY; TRACHEOSTOMY TUBE; ANIMAL; ANIMAL MODEL; CLINICAL COMPETENCE; COMPARATIVE STUDY; CROSSOVER PROCEDURE; EDUCATION; HEALTH PERSONNEL ATTITUDE; ITALY; LEARNING CURVE; MEDICAL EDUCATION; MOTOR PERFORMANCE; PIG; PROCEDURES; QUESTIONNAIRE; RANDOMIZED CONTROLLED TRIAL; TASK PERFORMANCE; TEACHING;

EID: 84922454016     PISSN: 15699293     EISSN: 15699285     Source Type: Journal    
DOI: 10.1093/icvts/ivu382     Document Type: Article
Times cited : (17)

References (20)
  • 1
    • 33846427867 scopus 로고    scopus 로고
    • Percutaneous tracheostomy-long-Term outlook, a review
    • Sviri S, van Heerden PV, Samie R. Percutaneous tracheostomy-long-Term outlook, a review. Crit Care Resusc 2004;6:280-4.
    • (2004) Crit Care Resusc , vol.6 , pp. 280-284
    • Sviri, S.1    Van Heerden, P.V.2    Samie, R.3
  • 3
    • 0025856585 scopus 로고
    • Percutaneous dilational tracheostomy a bedside procedure on the intensive care unit
    • Bodenham A, Diament R, Cohen A, Webster N. Percutaneous dilational tracheostomy. A bedside procedure on the intensive care unit. Anaesthesia 1991;46:570-2.
    • (1991) Anaesthesia , vol.46 , pp. 570-572
    • Bodenham, A.1    Diament, R.2    Cohen, A.3    Webster, N.4
  • 6
    • 0028085022 scopus 로고
    • The percutaneous dilatational subcricoid tracheostomy
    • Earl PD, Lowry JC. The percutaneous dilatational subcricoid tracheostomy. Br J Oral Maxillofac Surg 1994;32:24-5.
    • (1994) Br J Oral Maxillofac Surg , vol.32 , pp. 24-25
    • Earl, P.D.1    Lowry, J.C.2
  • 7
    • 0024542702 scopus 로고
    • Evaluation of an animal model for teaching fibreoptic tracheal intubation
    • Forbes RB, Murray DJ, Albanese MA. Evaluation of an animal model for teaching fibreoptic tracheal intubation. Can J Anaesth 1989;36:141-4.
    • (1989) Can J Anaesth , vol.36 , pp. 141-144
    • Forbes, R.B.1    Murray, D.J.2    Albanese, M.A.3
  • 8
    • 0037879044 scopus 로고    scopus 로고
    • Percutaneous dilatational tra- cheostomy in the icu: Optimal organization, low compli- cation rates, and description of a new complication
    • Polderman KH, Spijkstra JJ, de Bree R, Christiaans HM, Gelissen HP, Wester JP, et al. Percutaneous dilatational tra- cheostomy in the ICU: optimal organization, low compli- cation rates, and description of a new complication. Chest 2003;123:1595-602.
    • (2003) Chest , vol.123 , pp. 1595-1602
    • Polderman, K.H.1    Spijkstra, J.J.2    De Bree, R.3    Christiaans, H.M.4    Gelissen, H.P.5    Wester, J.P.6
  • 9
    • 0033918408 scopus 로고    scopus 로고
    • Endoscopically monitored percutaneous dilational tracheotomy in a residency program
    • Donaldson DR, Emami AJ, Wax MK. Endoscopically monitored percutaneous dilational tracheotomy in a residency program. Laryngoscope 2000; 110:1142-6.
    • (2000) Laryngoscope , vol.110 , pp. 1142-1146
    • Donaldson, D.R.1    Emami, A.J.2    Wax, M.K.3
  • 11
    • 0033810088 scopus 로고    scopus 로고
    • Bedside percutaneous tracheostomy: Prospective evaluation of a modification of the current technique in 100 patients
    • Velmahos GC, Gomez H, Boicey CM, Demetriades D. Bedside percutaneous tracheostomy: prospective evaluation of a modification of the current technique in 100 patients. World J Surg 2000;24:1109-15.
    • (2000) World J Surg , vol.24 , pp. 1109-1115
    • Velmahos, G.C.1    Gomez, H.2    Boicey, C.M.3    Demetriades, D.4
  • 13
    • 34447560934 scopus 로고    scopus 로고
    • Clinical review: Percutaneous dilatational tracheostomy
    • Al-Ansari MA, Hijazi MH. Clinical review: percutaneous dilatational tracheostomy. Crit Care 2006;10:202.
    • (2006) Crit Care , vol.10 , pp. 202
    • Al-Ansari, M.A.1    Hijazi, M.H.2
  • 15
    • 79953693872 scopus 로고    scopus 로고
    • Anatomical particularities and difficulties in tracheostomy: Seeking the best way
    • Ferraro F, Di Lorenzo A, Lettieri B, Chiefari M. Anatomical particularities and difficulties in tracheostomy: seeking the best way. Minerva Anestesiol 2011;77:378-9.
    • (2011) Minerva Anestesiol , vol.77 , pp. 378-379
    • Ferraro, F.1    Di Lorenzo, A.2    Lettieri, B.3    Chiefari, M.4
  • 17
    • 79957973620 scopus 로고    scopus 로고
    • Spontaneous expectoration of an obstructive fibrinous tracheal pseudomembrane after tracheal intubation
    • Fiorelli A, Vicidomini G, Messina G, Santini M. Spontaneous expectoration of an obstructive fibrinous tracheal pseudomembrane after tracheal intubation. Eur J Cardiothorac Surg 2011;40:261-3.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 261-263
    • Fiorelli, A.1    Vicidomini, G.2    Messina, G.3    Santini, M.4
  • 18
    • 84866564101 scopus 로고    scopus 로고
    • Acute life-Threatening airway obstruction with pseudomembrane formation after percutaneous dilational tracheostomy
    • Fiorelli A, Accardo M, D'Elia A, Santini M, Ferraro F. Acute life-Threatening airway obstruction with pseudomembrane formation after percutaneous dilational tracheostomy. Anaesth Intensive Care 2012;40:904-5.
    • (2012) Anaesth Intensive Care , vol.40 , pp. 904-905
    • Fiorelli, A.1    Accardo, M.2    D'Elia, A.3    Santini, M.4    Ferraro, F.5
  • 19
    • 56249113017 scopus 로고    scopus 로고
    • Comparison of manikin versus porcine models in cricothyrotomy procedure training
    • Cho J, Kang GH, Kim EC, Oh YM, Choi HJ, Im TH, et al. Comparison of manikin versus porcine models in cricothyrotomy procedure training. Emerg Med J 2008;25:732-4.
    • (2008) Emerg Med J , vol.25 , pp. 732-734
    • Cho, J.1    Kang, G.H.2    Kim, E.C.3    Oh, Y.M.4    Choi, H.J.5    Im, T.H.6
  • 20
    • 0030777514 scopus 로고    scopus 로고
    • A laboratory comparison of two techniques of emergency percutaneous tracheostomy
    • McLure HA, Dob DP, Mannan MM, Soni N. A laboratory comparison of two techniques of emergency percutaneous tracheostomy. Anaesthesia 1997;52:1199-201.
    • (1997) Anaesthesia , vol.52 , pp. 1199-1201
    • McLure, H.A.1    Dob, D.P.2    Mannan, M.M.3    Soni, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.