메뉴 건너뛰기




Volumn 40, Issue , 2014, Pages 204-211

Fabrication of gallium hexacyanoferrate modified carbon ionic liquid paste electrode for sensitive determination of hydrogen peroxide and glucose

Author keywords

Carbon ionic liquid paste electrode; Electrochemical sensor; Gallium hexacyanoferrate modified electrode; Glucose; Hydrogen peroxide

Indexed keywords

CARBON; ELECTROCATALYSIS; ELECTROCHEMICAL SENSORS; GALLIUM; GLUCOSE; GLUCOSE SENSORS; HYDROGEN PEROXIDE; IONIC LIQUIDS; PEROXIDES; REDOX REACTIONS;

EID: 84922395168     PISSN: 09284931     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.msec.2014.03.058     Document Type: Article
Times cited : (26)

References (33)
  • 2
    • 0041561009 scopus 로고    scopus 로고
    • Prussian blue modified carbon nanotube paste electrodes: A comparative study and a biochemical application
    • F. Ricci, A. Amine, D. Moscone, and G. Palleschi Prussian blue modified carbon nanotube paste electrodes: a comparative study and a biochemical application Anal. Lett. 36 2003 1921 1938
    • (2003) Anal. Lett. , vol.36 , pp. 1921-1938
    • Ricci, F.1    Amine, A.2    Moscone, D.3    Palleschi, G.4
  • 3
    • 27844496980 scopus 로고    scopus 로고
    • An ionic liquid-type carbon paste polyoxometalate-modified electrode and its properties
    • H.T. Liu, P. He, Z.Y. Li, C.Y. Sun, L.H. Shi, Y. Liu, G.Y. Zhu, and J.H. Li An ionic liquid-type carbon paste polyoxometalate-modified electrode and its properties Electrochem. Commun. 7 2005 1357 1363
    • (2005) Electrochem. Commun. , vol.7 , pp. 1357-1363
    • Liu, H.T.1    He, P.2    Li, Z.Y.3    Sun, C.Y.4    Shi, L.H.5    Liu, Y.6    Zhu, G.Y.7    Li, J.H.8
  • 4
    • 66649089790 scopus 로고    scopus 로고
    • Electrochemical characterization and application of carbon ionic liquid electrodes containing 1:12 phosphomolybdic acid
    • B. Haghighi, and H. Hamidi Electrochemical characterization and application of carbon ionic liquid electrodes containing 1:12 phosphomolybdic acid Electroanalysis 21 2009 1057 1065
    • (2009) Electroanalysis , vol.21 , pp. 1057-1065
    • Haghighi, B.1    Hamidi, H.2
  • 5
    • 33744902611 scopus 로고    scopus 로고
    • High-performance carbon composite electrode based on an ionic liquid as a binder
    • N. Maleki, A. Safavi, and F. Tajabadi High-performance carbon composite electrode based on an ionic liquid as a binder Anal. Chem. 78 2006 3820 3826
    • (2006) Anal. Chem. , vol.78 , pp. 3820-3826
    • Maleki, N.1    Safavi, A.2    Tajabadi, F.3
  • 6
    • 70249087361 scopus 로고    scopus 로고
    • Prussian blue modified carbon ionic liquid electrode: Electrochemical characterization and its application for hydrogen peroxide and glucose measurements
    • B. Haghighi, and R. Nikzad Prussian blue modified carbon ionic liquid electrode: electrochemical characterization and its application for hydrogen peroxide and glucose measurements Electroanalysis 21 2009 1862 1868
    • (2009) Electroanalysis , vol.21 , pp. 1862-1868
    • Haghighi, B.1    Nikzad, R.2
  • 8
    • 0033533263 scopus 로고    scopus 로고
    • Prussian blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors
    • A.A. Karyakin, and E.E. Karyakina Prussian blue-based 'artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensors Sensors Actuators B Chem. 57 1999 268 273
    • (1999) Sensors Actuators B Chem. , vol.57 , pp. 268-273
    • Karyakin, A.A.1    Karyakina, E.E.2
  • 9
    • 0042526132 scopus 로고    scopus 로고
    • Metal hexacyanoferrates: Electrosynthesis, in situ characterization, and applications
    • N.R. de Tacconi, K. Rajeshwar, and R.O. Lezna Metal hexacyanoferrates: electrosynthesis, in situ characterization, and applications Chem. Mater. 15 2003 3046 3062
    • (2003) Chem. Mater. , vol.15 , pp. 3046-3062
    • De Tacconi, N.R.1    Rajeshwar, K.2    Lezna, R.O.3
  • 10
    • 33847355117 scopus 로고    scopus 로고
    • Preparation, electrochemical behavior and performance of gallium hexacyanoferrate as electrocatalyst of H2O2
    • H. Yu, Q.L. Sheng, and J. Bin Zheng Preparation, electrochemical behavior and performance of gallium hexacyanoferrate as electrocatalyst of H 2O2 Electrochim. Acta 52 2007 4403 4410
    • (2007) Electrochim. Acta , vol.52 , pp. 4403-4410
    • Yu, H.1    Sheng, Q.L.2    Bin Zheng, J.3
  • 11
    • 0032575961 scopus 로고    scopus 로고
    • Mixture design-design generation, PLS analysis, and model usage
    • L. Eriksson, E. Johansson, and C. Wikström Mixture design-design generation, PLS analysis, and model usage Intell. Lab. Syst. 43 1998 1 24
    • (1998) Intell. Lab. Syst. , vol.43 , pp. 1-24
    • Eriksson, L.1    Johansson, E.2    Wikström, C.3
  • 15
    • 0032486067 scopus 로고    scopus 로고
    • A graphical approach for evaluating and comparing designs for nonlinear models
    • A.I. Khuri, and J.Y. Lee A graphical approach for evaluating and comparing designs for nonlinear models Comput. Stat. Data Anal. 27 1998 433 443
    • (1998) Comput. Stat. Data Anal. , vol.27 , pp. 433-443
    • Khuri, A.I.1    Lee, J.Y.2
  • 16
    • 0000432952 scopus 로고
    • Simultaneous optimization of several response variables
    • G. Derringer, and R. Suich Simultaneous optimization of several response variables J. Qual. Technol. 12 1980 214 219
    • (1980) J. Qual. Technol. , vol.12 , pp. 214-219
    • Derringer, G.1    Suich, R.2
  • 17
    • 84868608033 scopus 로고    scopus 로고
    • Fabrication and application of a sensitive and highly stable copper hexacyanoferrate modified carbon ionic liquid paste electrode for hydrogen peroxide and glucose detection
    • B. Haghighi, L. Nazari, and S.M. Sajjadi Fabrication and application of a sensitive and highly stable copper hexacyanoferrate modified carbon ionic liquid paste electrode for hydrogen peroxide and glucose detection Electroanalysis 24 2012 2165 2175
    • (2012) Electroanalysis , vol.24 , pp. 2165-2175
    • Haghighi, B.1    Nazari, L.2    Sajjadi, S.M.3
  • 18
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Laviron General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems J. Electroanal. Chem. 101 1979 19
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19
    • Laviron, E.1
  • 19
    • 0003064221 scopus 로고    scopus 로고
    • On the mechanism of H2O2 reduction at Prussian blue modified electrodes
    • A.A. Karyakin, E.E. Karyakina, and L. Gorton On the mechanism of H 2O2 reduction at Prussian blue modified electrodes Electrochem. Commun. 1 1999 78 82
    • (1999) Electrochem. Commun. , vol.1 , pp. 78-82
    • Karyakin, A.A.1    Karyakina, E.E.2    Gorton, L.3
  • 20
    • 0001645720 scopus 로고
    • A high-sensitive glucose amperometric biosensor based on Prussian-blue modified electrodes
    • A.A. Karyakin, O.V. Gitelmacher, and E.E. Karyakina A high-sensitive glucose amperometric biosensor based on Prussian-blue modified electrodes Anal. Lett. 27 1994 2861 2869
    • (1994) Anal. Lett. , vol.27 , pp. 2861-2869
    • Karyakin, A.A.1    Gitelmacher, O.V.2    Karyakina, E.E.3
  • 21
    • 0000855109 scopus 로고
    • Prussian blue based first-generation biosensor - A sensitive amperometric electrode for glucose
    • A.A. Karyakin, O.V. Gitelmacher, and E.E. Karyakina Prussian blue based first-generation biosensor - a sensitive amperometric electrode for glucose Anal. Chem. 67 1995 2419 2423
    • (1995) Anal. Chem. , vol.67 , pp. 2419-2423
    • Karyakin, A.A.1    Gitelmacher, O.V.2    Karyakina, E.E.3
  • 22
    • 2442464697 scopus 로고    scopus 로고
    • Enzyme-mediated amperometric biosensors prepared with the layer-by-layer (LbL) adsorption technique
    • M. Ferreira, P.A. Fiorito, O.N. Oliveira, and S.I.C. de Torresi Enzyme-mediated amperometric biosensors prepared with the layer-by-layer (LbL) adsorption technique Biosens. Bioelectron. 19 2004 1611 1615
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1611-1615
    • Ferreira, M.1    Fiorito, P.A.2    Oliveira, O.N.3    De Torresi, S.I.C.4
  • 23
    • 77951621976 scopus 로고    scopus 로고
    • Gold nanoparticles based sandwich electrochemical immunosensor
    • G.K. Ahirwal, and C.K. Mitra Gold nanoparticles based sandwich electrochemical immunosensor Biosens. Bioelectron. 25 2010 2016 2020
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 2016-2020
    • Ahirwal, G.K.1    Mitra, C.K.2
  • 24
    • 78049426497 scopus 로고    scopus 로고
    • Enzyme functionalized nanoparticles for electrochemical biosensors: A comparative study with applications for the detection of bisphenol A
    • R.S.J. Alkasir, M. Ganesana, Y.H. Won, L. Stanciu, and S. Andreescu Enzyme functionalized nanoparticles for electrochemical biosensors: a comparative study with applications for the detection of bisphenol A Biosens. Bioelectron. 26 2010 43 49
    • (2010) Biosens. Bioelectron. , vol.26 , pp. 43-49
    • Alkasir, R.S.J.1    Ganesana, M.2    Won, Y.H.3    Stanciu, L.4    Andreescu, S.5
  • 25
    • 71849106673 scopus 로고    scopus 로고
    • Preparation and optimization of a bienzymic biosensor based on self-assembled monolayer modified gold electrode for alcohol and glucose detection
    • E. Asav, and E. Akyilmaz Preparation and optimization of a bienzymic biosensor based on self-assembled monolayer modified gold electrode for alcohol and glucose detection Biosens. Bioelectron. 25 2010 1014 1018
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 1014-1018
    • Asav, E.1    Akyilmaz, E.2
  • 26
    • 77955470300 scopus 로고    scopus 로고
    • Glucose biosensing at carbon paste electrodes containing iron nanoparticles
    • F.N. Comba, M.D. Rubianes, P. Herrasti, and G.A. Rivas Glucose biosensing at carbon paste electrodes containing iron nanoparticles Sensors Actuators B Chem. 149 2010 306 309
    • (2010) Sensors Actuators B Chem. , vol.149 , pp. 306-309
    • Comba, F.N.1    Rubianes, M.D.2    Herrasti, P.3    Rivas, G.A.4
  • 27
    • 77954544247 scopus 로고    scopus 로고
    • Highly sensitive and selective glucose biosensing at carbon paste electrodes modified with electrogenerated magnetite nanoparticles and glucose oxidase
    • F.N. Comba, M.D. Rubianes, L. Cabrera, S. Gutierrez, P. Herrasti, and G.A. Rivas Highly sensitive and selective glucose biosensing at carbon paste electrodes modified with electrogenerated magnetite nanoparticles and glucose oxidase Electroanalysis 22 2010 1566 1572
    • (2010) Electroanalysis , vol.22 , pp. 1566-1572
    • Comba, F.N.1    Rubianes, M.D.2    Cabrera, L.3    Gutierrez, S.4    Herrasti, P.5    Rivas, G.A.6
  • 28
    • 71849105709 scopus 로고    scopus 로고
    • Enzyme electrodes to monitor glucose consumption of single cardiac myocytes in sub-nanoliter volumes
    • I.A. Ges, and F. Baudenbacher Enzyme electrodes to monitor glucose consumption of single cardiac myocytes in sub-nanoliter volumes Biosens. Bioelectron. 25 2010 1019 1024
    • (2010) Biosens. Bioelectron. , vol.25 , pp. 1019-1024
    • Ges, I.A.1    Baudenbacher, F.2
  • 30
    • 77953912732 scopus 로고    scopus 로고
    • New amperometric glucose biosensor based on cross-linking of glucose oxidase on silica gel/multiwalled carbon nanotubes/polyacrylonitrile nanocomposite film
    • R. Nenkova, D. Ivanova, J. Vladimirova, and T. Godjevargova New amperometric glucose biosensor based on cross-linking of glucose oxidase on silica gel/multiwalled carbon nanotubes/polyacrylonitrile nanocomposite film Sensors Actuators B Chem. 148 2010 59 65
    • (2010) Sensors Actuators B Chem. , vol.148 , pp. 59-65
    • Nenkova, R.1    Ivanova, D.2    Vladimirova, J.3    Godjevargova, T.4
  • 31
    • 0035356251 scopus 로고    scopus 로고
    • Construction and analytical characterization of Prussian blue-based carbon paste electrodes and their assembly as oxidase enzyme sensors
    • D. Moscone, D. D'Ottavi, D. Compagnone, G. Palleschi, and A. Amine Construction and analytical characterization of Prussian blue-based carbon paste electrodes and their assembly as oxidase enzyme sensors Anal. Chem. 73 2001 2529 2535
    • (2001) Anal. Chem. , vol.73 , pp. 2529-2535
    • Moscone, D.1    D'Ottavi, D.2    Compagnone, D.3    Palleschi, G.4    Amine, A.5
  • 32
    • 70249123515 scopus 로고    scopus 로고
    • Enhancement of the electrochemical performance of Prussian blue modified electrode via ionic liquid treatment
    • L. Zhang, Z. Song, Q. Zhang, X. Jia, H. Zhang, and S. Xin Enhancement of the electrochemical performance of Prussian blue modified electrode via ionic liquid treatment Electroanalysis 21 2009 1835 1841
    • (2009) Electroanalysis , vol.21 , pp. 1835-1841
    • Zhang, L.1    Song, Z.2    Zhang, Q.3    Jia, X.4    Zhang, H.5    Xin, S.6
  • 33
    • 67349268431 scopus 로고    scopus 로고
    • Nonenzymatic hydrogen peroxide sensor based on a Prussian blue-modified carbon ionic liquid electrode
    • Y. Li, X. Liu, X. Zeng, Y. Liu, X. Liu, W. Wei, and S. Luo Nonenzymatic hydrogen peroxide sensor based on a Prussian blue-modified carbon ionic liquid electrode Microchim. Acta 165 2009 393 398
    • (2009) Microchim. Acta , vol.165 , pp. 393-398
    • Li, Y.1    Liu, X.2    Zeng, X.3    Liu, Y.4    Liu, X.5    Wei, W.6    Luo, S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.