메뉴 건너뛰기




Volumn 98, Issue 5, 2014, Pages 1627-1634

Novel emboli protection system during cardiac surgery: A multi-center, randomized, clinical trial

Author keywords

[No Author keywords available]

Indexed keywords

ADJUSTMENT DISORDER; ADULT; AGED; ANXIETY DISORDER; AORTA ARCH; AORTA VALVE REPLACEMENT; ARTICLE; ASCENDING AORTA; BRAIN DAMAGE; CANNULA; CEREBROVASCULAR ACCIDENT; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; DELIRIUM; DEPRESSION; DEVICE SAFETY; DIFFUSION WEIGHTED IMAGING; EMBOLI PROTECTION CANNULA; EMBOLIC PROTECTION DEVICE; FEMALE; HEART SURGERY; HUMAN; KIDNEY FAILURE; MAJOR CLINICAL STUDY; MALE; MESENTERIC ISCHEMIA; MULTICENTER STUDY; PERIPHERAL ISCHEMIA; POLYNEUROPATHY; POSTOPERATIVE COMPLICATION; PREOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; AORTIC VALVE STENOSIS; CLINICAL TRIAL; COMPARATIVE STUDY; EMBOLISM; EQUIPMENT DESIGN; FOLLOW UP; HEART VALVE REPLACEMENT; MIDDLE AGED; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84922358711     PISSN: 00034975     EISSN: 15526259     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2014.06.061     Document Type: Article
Times cited : (18)

References (24)
  • 1
    • 33745846469 scopus 로고    scopus 로고
    • Cardiopulmonary bypass management and neurologic outcomes: An evidence-based appraisal of current practices
    • Hogue CW Jr, Palin CA, Arrowsmith JE. Cardiopulmonary bypass management and neurologic outcomes: an evidence-based appraisal of current practices. Anesth Analg 2006;103:21-37.
    • (2006) Anesth Analg , vol.103 , pp. 21-37
    • Hogue, C.W.1    Palin, C.A.2    Arrowsmith, J.E.3
  • 2
    • 0034162011 scopus 로고    scopus 로고
    • Outcomes of cardiac surgery in patients > or = 80 years: Results from the National Cardiovascular Network
    • Alexander KP, Anstrom KJ, Muhlbaier LH, et al. Outcomes of cardiac surgery in patients > or = 80 years: results from the National Cardiovascular Network. J Am Coll Cardiol 2000;35:731-8.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 731-738
    • Alexander, K.P.1    Anstrom, K.J.2    Muhlbaier, L.H.3
  • 3
    • 38649114706 scopus 로고    scopus 로고
    • Mechanisms of cerebral injury from cardiac surgery
    • Hogue CW, Gottesman RF, Stearns J. Mechanisms of cerebral injury from cardiac surgery. Crit Care Clin 2008;24:83-98.
    • (2008) Crit Care Clin , vol.24 , pp. 83-98
    • Hogue, C.W.1    Gottesman, R.F.2    Stearns, J.3
  • 4
    • 0028914566 scopus 로고
    • Macroemboli and microemboli during cardiopulmonary bypass
    • Blauth CI. Macroemboli and microemboli during cardiopulmonary bypass. Ann Thorac Surg 1995;59:1300-3.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1300-1303
    • Blauth, C.I.1
  • 5
    • 10044261304 scopus 로고    scopus 로고
    • Mild to moderate atheromatous disease of the thoracic aorta and new ischemic brain lesions after conventional coronary artery bypass graft surgery
    • Djaiani G, Fedorko L, Borger M, et al. Mild to moderate atheromatous disease of the thoracic aorta and new ischemic brain lesions after conventional coronary artery bypass graft surgery. Stroke 2004;35:e356-8.
    • (2004) Stroke , vol.35 , pp. e356-e358
    • Djaiani, G.1    Fedorko, L.2    Borger, M.3
  • 6
    • 0345167161 scopus 로고    scopus 로고
    • Determination of etiologic mechanism of strokes secondary to coronary artery bypass graft surgery
    • Likosky DS, Marrin CA, Caplan LR, et al. Determination of etiologic mechanism of strokes secondary to coronary artery bypass graft surgery. Stroke 2003;34:2830-4.
    • (2003) Stroke , vol.34 , pp. 2830-2834
    • Likosky, D.S.1    Marrin, C.A.2    Caplan, L.R.3
  • 7
    • 84907110287 scopus 로고
    • Demonstration of cerebral microemboli occurring during coronary artery bypass graft surgery using fluorescein angiography
    • Arnold JV, Blauth CI, Smith PL, Jagoe JR, Wootton R, Taylor KM. Demonstration of cerebral microemboli occurring during coronary artery bypass graft surgery using fluorescein angiography. J Audiov Media Med 1990;13:87-90.
    • (1990) J Audiov Media Med , vol.13 , pp. 87-90
    • Arnold, J.V.1    Blauth, C.I.2    Smith, P.L.3    Jagoe, J.R.4    Wootton, R.5    Taylor, K.M.6
  • 8
    • 0026642567 scopus 로고
    • Atheroembolism from the ascending aorta: An emerging problem in cardiac surgery
    • Blauth CI, Cosgrove DM, Webb BW, et al. Atheroembolism from the ascending aorta: an emerging problem in cardiac surgery. J Thorac Cardiovasc Surg 1992;103:1104-11.
    • (1992) J Thorac Cardiovasc Surg , vol.103 , pp. 1104-1111
    • Blauth, C.I.1    Cosgrove, D.M.2    Webb, B.W.3
  • 9
    • 0028033001 scopus 로고
    • Cerebral emboli detected during bypass surgery are associated with clamp removal
    • Barbut D, Hinton RB, Szatrowski TP, et al. Cerebral emboli detected during bypass surgery are associated with clamp removal. Stroke 1994;25:2398-402.
    • (1994) Stroke , vol.25 , pp. 2398-2402
    • Barbut, D.1    Hinton, R.B.2    Szatrowski, T.P.3
  • 10
    • 0032824462 scopus 로고    scopus 로고
    • Decreased cerebral emboli during distal aortic arch cannulation: A randomized clinical trial
    • Borger MA, Taylor RL, Weisel RD, et al. Decreased cerebral emboli during distal aortic arch cannulation: a randomized clinical trial. J Thorac Cardiovasc Surg 1999;118:740-5.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 740-745
    • Borger, M.A.1    Taylor, R.L.2    Weisel, R.D.3
  • 12
    • 84899654653 scopus 로고    scopus 로고
    • Cerebral dysfunction after coronary artery bypass surgery
    • Goto T, Maekawa K. Cerebral dysfunction after coronary artery bypass surgery. J Anesth 2014;28:242-8.
    • (2014) J Anesth , vol.28 , pp. 242-248
    • Goto, T.1    Maekawa, K.2
  • 13
    • 67649810705 scopus 로고    scopus 로고
    • The EmBlocker: Efficiency of a new ultrasonic embolic protection device adjunctive to heart valve surgery
    • Sauren LD, la Meir M, Bolotin G, et al. The EmBlocker: efficiency of a new ultrasonic embolic protection device adjunctive to heart valve surgery. Ann Thorac Surg 2009;88:253-7.
    • (2009) Ann Thorac Surg , vol.88 , pp. 253-257
    • Sauren, L.D.1    La Meir, M.2    Bolotin, G.3
  • 14
    • 79959836271 scopus 로고    scopus 로고
    • A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention
    • Carpenter JP, Carpenter JT, Tellez A, Webb JG, Yi GH, Granada JF. A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention. J Vasc Surg 2011;54:174-81.
    • (2011) J Vasc Surg , vol.54 , pp. 174-181
    • Carpenter, J.P.1    Carpenter, J.T.2    Tellez, A.3    Webb, J.G.4    Yi, G.H.5    Granada, J.F.6
  • 15
    • 0042158363 scopus 로고    scopus 로고
    • Emboli capture using the Embol-X intraaortic filter in cardiac surgery: A multicentered randomized trial of 1,289 patients
    • Banbury MK, Kouchoukos NT, Allen KB, et al. Emboli capture using the Embol-X intraaortic filter in cardiac surgery: a multicentered randomized trial of 1,289 patients. Ann Thorac Surg 2003;76:508-15.
    • (2003) Ann Thorac Surg , vol.76 , pp. 508-515
    • Banbury, M.K.1    Kouchoukos, N.T.2    Allen, K.B.3
  • 16
    • 33244464295 scopus 로고    scopus 로고
    • Intra-aortic filtration: Capturing particulate emboli during aortic cross-clamping
    • Christenson JT, Vala DL, Licker M, Sierra J, Kalangos A. Intra-aortic filtration: capturing particulate emboli during aortic cross-clamping. Tex Heart Inst J 2005;32:515-21.
    • (2005) Tex Heart Inst J , vol.32 , pp. 515-521
    • Christenson, J.T.1    Vala, D.L.2    Licker, M.3    Sierra, J.4    Kalangos, A.5
  • 17
    • 0036090620 scopus 로고    scopus 로고
    • Modified National Institutes of Health Stroke Scale for use in stroke clinical trials: Prospective reliability and validity
    • Meyer BC, Hemmen TM, Jackson CM, Lyden PD. Modified National Institutes of Health Stroke Scale for use in stroke clinical trials: prospective reliability and validity. Stroke 2002;33:1261-6.
    • (2002) Stroke , vol.33 , pp. 1261-1266
    • Meyer, B.C.1    Hemmen, T.M.2    Jackson, C.M.3    Lyden, P.D.4
  • 18
    • 84903270464 scopus 로고    scopus 로고
    • A comparison of traditional and novel definitions (RIFLE, AKIN, and KDIGO) of acute kidney injury for the prediction of outcomes in acute decompensated heart failure
    • Roy AK, Mc Gorrian C, Treacy C, et al. A comparison of traditional and novel definitions (RIFLE, AKIN, and KDIGO) of acute kidney injury for the prediction of outcomes in acute decompensated heart failure. Cardiorenal Med 2013;3:26-37.
    • (2013) Cardiorenal Med , vol.3 , pp. 26-37
    • Roy, A.K.1    Mc Gorrian, C.2    Treacy, C.3
  • 19
    • 1842471338 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: Implications for future neuroprotective trials?
    • Stolz E, Gerriets T, Kluge A, Klövekorn WP, Kaps M, Bachmann G. Diffusion-weighted magnetic resonance imaging and neurobiochemical markers after aortic valve replacement: implications for future neuroprotective trials? Stroke 2004;35:888-92.
    • (2004) Stroke , vol.35 , pp. 888-892
    • Stolz, E.1    Gerriets, T.2    Kluge, A.3    Klövekorn, W.P.4    Kaps, M.5    Bachmann, G.6
  • 22
    • 79958297729 scopus 로고    scopus 로고
    • Is the Montreal Cognitive Assessment superior to the Mini-mental State Examination to detect poststroke cognitive impairment? A study with neuropsychological evaluation
    • Godefroy O, Fickl A, Roussel M, et al. Is the Montreal Cognitive Assessment superior to the Mini-mental State Examination to detect poststroke cognitive impairment? A study with neuropsychological evaluation. Stroke 2011;42:1712-6.
    • (2011) Stroke , vol.42 , pp. 1712-1716
    • Godefroy, O.1    Fickl, A.2    Roussel, M.3
  • 23
    • 77952542227 scopus 로고    scopus 로고
    • Neuropsychological outcomes after coronary artery bypass grafting
    • Selnes OA, Gottesman RF. Neuropsychological outcomes after coronary artery bypass grafting. J Int Neuropsychol Soc 2010;16:221-6.
    • (2010) J Int Neuropsychol Soc , vol.16 , pp. 221-226
    • Selnes, O.A.1    Gottesman, R.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.