메뉴 건너뛰기




Volumn , Issue , 2014, Pages 216-219

Redundant safety features in a high-channel-count retinal neurostimulator

Author keywords

biomedical electrodes; Biomedical engineering; integrated circuit design; retinal implant; retinal prosthesis

Indexed keywords

BIOMEDICAL ENGINEERING; ELECTROCHEMISTRY; INTEGRATED CIRCUIT DESIGN; INTEGRATED CIRCUIT MANUFACTURE; OPHTHALMOLOGY; PROSTHETICS; SAFETY ENGINEERING; TISSUE;

EID: 84920512165     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioCAS.2014.6981701     Document Type: Conference Paper
Times cited : (4)

References (13)
  • 1
    • 80054855770 scopus 로고    scopus 로고
    • A hermetic wireless subretinal neurostimulator fo r vision prostheses
    • S.K. Kelly, et al., "A Hermetic Wireless Subretinal Neurostimulator fo r Vision Prostheses," IEEE Trans. on Biomedical Engineering, vol. 58, no. 11, 2011, pp. 3197-3205.
    • (2011) IEEE Trans. on Biomedical Engineering , vol.58 , Issue.11 , pp. 3197-3205
    • Kelly, S.K.1
  • 2
    • 80155198289 scopus 로고    scopus 로고
    • Retinal prostheses: Current clinical results and future needs
    • J.D. Weiland,A.K. Cho,M.S. Humayun Retinal prostheses: current clinical results and future needs Ophthalmology 118 2011, 2227-2237.
    • (2011) Ophthalmology , vol.118 , pp. 2227-2237
    • Weiland, J.D.1    Cho, A.K.2    Humayun, M.S.3
  • 3
    • 84875383559 scopus 로고    scopus 로고
    • Attaining higher resolution visual prosthetics: A review of the factors and limitations
    • C.D. Eiber, N.H. Lovell, G.J. Suaning, " Attaining higher resolution visual prosthetics: a review of the factors and limitations," J. Neural Eng., vol. 10, no. 1, 2013, 17pp.
    • (2013) J. Neural Eng , vol.10 , Issue.1
    • Eiber, C.D.1    Lovell, N.H.2    Suaning, G.J.3
  • 4
    • 85052609804 scopus 로고    scopus 로고
    • Towards the bionic eye-The retinal implant: Surgical, ophthalmological and histopathological perspectives
    • N. Alteheld, G. Roessler, P. Walter, " Towards the bionic eye-The retinal implant: surgical, ophthalmological and histopathological perspectives, " Acta Neurochi. Suppl., vol. 97(2), 2007, pp. 487-493.
    • (2007) Acta Neurochi. Suppl , vol.97 , Issue.2 , pp. 487-493
    • Alteheld, N.1    Roessler, G.2    Walter, P.3
  • 5
    • 79952692042 scopus 로고    scopus 로고
    • Subretinal electronic chips allow blind patients to read letters and combine them to words
    • E. Zrenner, et al., " Subretinal electronic chips allow blind patients to read letters and combine them to words," Proc. Biol. Sci., vol. 278, 2011, pp. 1489-1497.
    • (2011) Proc. Biol. Sci , vol.278 , pp. 1489-1497
    • Zrenner, E.1
  • 7
    • 84864633552 scopus 로고    scopus 로고
    • A prototype 64-electrode stimulator in 65nm cmos process towards a high density epi-retinal prosthesis
    • N. Tran, et al., "A prototype 64-electrode stimulator in 65nm CMOS process towards a high density epi-retinal prosthesis," Proc. IEEE Eng. Med. Biol. Soc., 2011, pp. 6729-6732.
    • (2011) Proc. IEEE Eng. Med. Biol. Soc , pp. 6729-6732
    • Tran, N.1
  • 8
    • 84881077663 scopus 로고    scopus 로고
    • Asic design and data communications for the boston retinal prosthesis
    • D.B. Shire, et al., "ASIC Design and Data Communications for the Boston Retinal Prosthesis," Proc. IEEE Eng. in Medicine and Bio. Conf., 2012, pp. 292-295.
    • (2012) Proc. IEEE Eng. in Medicine and Bio. Conf , pp. 292-295
    • Shire, D.B.1
  • 9
    • 0345445897 scopus 로고    scopus 로고
    • Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials
    • J.F. Rizzo, J.L. Wyatt, J. Loewenstein, S.K. Kelly, D.B. Shire, " Perceptual Efficacy of Electrical Stimulation of Human Retina with a Microelectrode Array During Short-Term Surgical Trials, " Invest. O phth. and Visual Science, Vol. 44, No. 12, 2003, pp. 5362-5369.
    • (2003) Invest. O Phth. and Visual Science , vol.44 , Issue.12 , pp. 5362-5369
    • Rizzo, J.F.1    Wyatt, J.L.2    Loewenstein, J.3    Kelly, S.K.4    Shire, D.B.5
  • 11
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • D.R. Merrill, M. Bikson, J.G.R. Jeffreys, " Electrical Stimulation of Excitable Tissue: Design of Efficacious and Safe Protocols," J. Neuroscience Methods, Vol. 141, 2005, pp. 171-198.
    • (2005) J. Neuroscience Methods , vol.141 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jeffreys, J.G.R.3
  • 12
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulating and recording electrodes
    • S.F. Cogan, "Neural Stimulating and Recording Electrodes, " Ann. Rev. Biomed. Eng., Vol. 10, 2008, pp. 275-309.
    • (2008) Ann. Rev. Biomed. Eng , vol.10 , pp. 275-309
    • Cogan, S.F.1
  • 13
    • 84870783777 scopus 로고    scopus 로고
    • On the cause and control of residual voltage generated by electrical stimulation of neural tissue
    • A. Krishnan, S.K. Kelly, " On the Cause and Control of Residual Voltage Generated by Electrical Stimulation of Neural Tissue," Proc. IEEE Eng. in Medicine and Bio. Conf., 2012, pp. 3899-3902.
    • (2012) Proc. IEEE Eng. in Medicine and Bio. Conf , pp. 3899-3902
    • Krishnan, A.1    Kelly, S.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.