-
1
-
-
0026601505
-
Magnetic bead purification of M13 DNA sequencing templates
-
PID: 1621955, COI: 1:CAS:528:DyaK38Xht1ajtLg%3D
-
Alderton, R. P., L. M. Eccleston, R. P. Howe, C. A. Read, M. A. Reeve, and S. Beck. Magnetic bead purification of M13 DNA sequencing templates. Anal. Biochem. 201:166–169, 1992.
-
(1992)
Anal. Biochem.
, vol.201
, pp. 166-169
-
-
Alderton, R.P.1
Eccleston, L.M.2
Howe, R.P.3
Read, C.A.4
Reeve, M.A.5
Beck, S.6
-
2
-
-
84867535673
-
Programmable magnetic tweezers and droplet microfluidic device for high-throughput nanoliter multi-step assays
-
COI: 1:CAS:528:DC%2BC38Xhtl2qu7%2FJ
-
Ali-Cherif, A., S. Begolo, S. Descroix, J. L. Viovy, and L. Malaquin. Programmable magnetic tweezers and droplet microfluidic device for high-throughput nanoliter multi-step assays. Angew. Chem. Int. Ed. 51(43):10765–10769, 2012.
-
(2012)
Angew. Chem. Int. Ed.
, vol.51
, Issue.43
, pp. 10765-10769
-
-
Ali-Cherif, A.1
Begolo, S.2
Descroix, S.3
Viovy, J.L.4
Malaquin, L.5
-
3
-
-
84858712135
-
Real-time droplet DNA amplification with a new tablet platform
-
PID: 22320164, COI: 1:CAS:528:DC%2BC38XhvVSqsLs%3D
-
Angione, S. L., A. Chauhan, and Tripathi. Real-time droplet DNA amplification with a new tablet platform. Anal. Chem. 84(6):2654–2661, 2012.
-
(2012)
Anal. Chem.
, vol.84
, Issue.6
, pp. 2654-2661
-
-
Angione, S.L.1
Chauhan, A.2
Tripathi3
-
4
-
-
84901034964
-
-
Athamanolap, P., D. J. Shin, and T. H. Wang. Droplet array platform for high-resolution melt analysis of DNA methylation density. J. Lab. Autom. 19(3):304–312, 2013.
-
(2013)
Autom
, vol.19
, Issue.3
, pp. 304-312
-
-
Athamanolap, P.1
Shin, D.J.2
-
5
-
-
84887360488
-
The FilmArray® respiratory panel: an automated, broadly multiplexed molecular test for the rapid and accurate detection of respiratory pathogens
-
PID: 24151847, COI: 1:CAS:528:DC%2BC3sXhs1Krs7vE
-
Babady, N. E. The FilmArray® respiratory panel: an automated, broadly multiplexed molecular test for the rapid and accurate detection of respiratory pathogens. Expert Rev. Mol. Diagn. 13(8):779–788, 2013.
-
(2013)
Expert Rev. Mol. Diagn.
, vol.13
, Issue.8
, pp. 779-788
-
-
Babady, N.E.1
-
6
-
-
37249004460
-
Magnetic particles for the separation and purification of nucleic acids
-
PID: 17063328, COI: 1:CAS:528:DC%2BD2sXot1Gj
-
Berensmeier, S. Magnetic particles for the separation and purification of nucleic acids. Appl. Microbiol. Biotechnol. 73(3):495–504, 2006.
-
(2006)
Appl. Microbiol. Biotechnol.
, vol.73
, Issue.3
, pp. 495-504
-
-
Berensmeier, S.1
-
7
-
-
79955369547
-
One-step purification of nucleic acid for gene expression analysis via Immiscible Filtration Assisted by Surface Tension (IFAST)
-
PID: 21423999, COI: 1:CAS:528:DC%2BC3MXlt1GntL0%3D
-
Berry, S. M., E. T. Alarid, and D. J. Beebe. One-step purification of nucleic acid for gene expression analysis via Immiscible Filtration Assisted by Surface Tension (IFAST). Lab Chip 11(10):1747–1753, 2011.
-
(2011)
Lab Chip
, vol.11
, Issue.10
, pp. 1747-1753
-
-
Berry, S.M.1
Alarid, E.T.2
Beebe, D.J.3
-
8
-
-
81255146502
-
Droplet-based pyrosequencing using digital microfluidics
-
PID: 21932784, COI: 1:CAS:528:DC%2BC3MXhtlWjt7fI
-
Boles, D. J., J. L. Benton, G. J. Siew, M. H. Levy, P. K. Thwar, M. A. Sandahl, J. L. Rouse, L. C. Perkins, A. P. Sudarsan, R. Jalili, V. K. Pamula, V. Srinivasan, R. B. Fair, P. G. Griffin, A. E. Eckhardt, and M. G. Pollack. Droplet-based pyrosequencing using digital microfluidics. Anal. Chem. 83(22):8439–8447, 2011.
-
(2011)
Anal. Chem.
, vol.83
, Issue.22
, pp. 8439-8447
-
-
Boles, D.J.1
Benton, J.L.2
Siew, G.J.3
Levy, M.H.4
Thwar, P.K.5
Sandahl, M.A.6
Rouse, J.L.7
Perkins, L.C.8
Sudarsan, A.P.9
Jalili, R.10
Pamula, V.K.11
Srinivasan, V.12
Fair, R.B.13
Griffin, P.G.14
Eckhardt, A.E.15
Pollack, M.G.16
-
9
-
-
0032538386
-
An integrated nanoliter DNA analysis device
-
PID: 9774277, COI: 1:CAS:528:DyaK1cXmsleisLc%3D
-
Burns, M. A., B. N. Johnson, S. N. Brahmasandra, K. Handique, J. R. Webster, M. Krishnan, T. S. Sammarco, P. M. Man, D. Jones, D. Heldsinger, C. H. Mastrangelo, and D. T. Burke. An integrated nanoliter DNA analysis device. Science 282(5388):484–487, 1998.
-
(1998)
Science
, vol.282
, Issue.5388
, pp. 484-487
-
-
Burns, M.A.1
Johnson, B.N.2
Brahmasandra, S.N.3
Handique, K.4
Webster, J.R.5
Krishnan, M.6
Sammarco, T.S.7
Man, P.M.8
Jones, D.9
Heldsinger, D.10
Mastrangelo, C.H.11
Burke, D.T.12
-
10
-
-
79953785400
-
Multiplex PCR and emerging technologies for the detection of respiratory pathogens
-
PID: 21460291
-
Caliendo, A. M. Multiplex PCR and emerging technologies for the detection of respiratory pathogens. Clin. Infect. Dis. 52(S4):S326–S330, 2011.
-
(2011)
Clin. Infect. Dis.
, vol.52
, Issue.S4
, pp. S326-S330
-
-
Caliendo, A.M.1
-
11
-
-
77957366874
-
An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids
-
Chen, D. F., M. Mauk, X. Qiu, C. Liu, J. Kim, S. Ramprasad, S. Ongagna, W. R. Abrams, D. Malamud, P. L. A. M. Corstjens, and H. H. Bau. An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids. Biomed. Microdev. 12(4):705–719, 2010.
-
(2010)
Biomed. Microdev.
, vol.12
, Issue.4
, pp. 705-719
-
-
Chen, D.F.1
Mauk, M.2
Qiu, X.3
Liu, C.4
Kim, J.5
Ramprasad, S.6
Ongagna, S.7
Abrams, W.R.8
Malamud, D.9
Corstjens, P.L.A.M.10
Bau, H.H.11
-
12
-
-
0038392962
-
Light actuation of liquid by optoelectrowetting
-
COI: 1:CAS:528:DC%2BD3sXjsVegurk%3D
-
Chiou, P. Y., H. Moon, H. Toshiyoshi, C. J. Kim, and M. C. Wu. Light actuation of liquid by optoelectrowetting. Sens. Actuators A 104(3):222–228, 2003.
-
(2003)
Sens. Actuators A
, vol.104
, Issue.3
, pp. 222-228
-
-
Chiou, P.Y.1
Moon, H.2
Toshiyoshi, H.3
Kim, C.J.4
Wu, M.C.5
-
13
-
-
84880167613
-
Topography-assisted electromagnetic platform for blood-to-PCR in a droplet
-
PID: 23835223, COI: 1:CAS:528:DC%2BC3sXhsVWqs7jL
-
Chiou, C. H., D. J. Shin, Y. Zhang, and T. H. Wang. Topography-assisted electromagnetic platform for blood-to-PCR in a droplet. Biosens. Bioelectron. 50:91–99, 2013.
-
(2013)
Biosens. Bioelectron.
, vol.50
, pp. 91-99
-
-
Chiou, C.H.1
Shin, D.J.2
Zhang, Y.3
Wang, T.H.4
-
14
-
-
79952312775
-
Reliable and low-voltage electrowetting on thin parylene films
-
COI: 1:CAS:528:DC%2BC3MXjsVGnsbo%3D
-
Dhindsa, M., S. Kuiper, and J. Heikenfeld. Reliable and low-voltage electrowetting on thin parylene films. Thin Solid Films 519:3346–3351, 2011.
-
(2011)
Thin Solid Films
, vol.519
, pp. 3346-3351
-
-
Dhindsa, M.1
Kuiper, S.2
Heikenfeld, J.3
-
15
-
-
65349130617
-
General digital microfluidic platform manipulating dielectric and conductive droplets by dielectrophoresis and electrowetting
-
PID: 19370242, COI: 1:CAS:528:DC%2BD1MXksF2hsbw%3D
-
Fan, S. K., T. H. Hsieh, and D. Y. Lin. General digital microfluidic platform manipulating dielectric and conductive droplets by dielectrophoresis and electrowetting. Lab Chip 9(9):1236–1242, 2009.
-
(2009)
Lab Chip
, vol.9
, Issue.9
, pp. 1236-1242
-
-
Fan, S.K.1
Hsieh, T.H.2
Lin, D.Y.3
-
16
-
-
79960905844
-
Capillary-driven multiparametric microfluidic chips for one-step immunoassays
-
PID: 21752632, COI: 1:CAS:528:DC%2BC3MXpvFWntLg%3D
-
Gervais, L., M. Hitzbleck, and E. Delamarche. Capillary-driven multiparametric microfluidic chips for one-step immunoassays. Biosens. Bioelectron. 27(1):64–70, 2011.
-
(2011)
Biosens. Bioelectron.
, vol.27
, Issue.1
, pp. 64-70
-
-
Gervais, L.1
Hitzbleck, M.2
Delamarche, E.3
-
17
-
-
10644277303
-
Rapid PCR in a continuous flow device
-
PID: 15570378, COI: 1:CAS:528:DC%2BD2cXhtVektLrM
-
Hashimoto, M., P. C. Chen, M. W. Mitchell, D. E. Nikitopoulos, S. A. Soper, and M. C. Murphy. Rapid PCR in a continuous flow device. Lab Chip 4:638–645, 2004.
-
(2004)
Lab Chip
, vol.4
, pp. 638-645
-
-
Hashimoto, M.1
Chen, P.C.2
Mitchell, M.W.3
Nikitopoulos, D.E.4
Soper, S.A.5
Murphy, M.C.6
-
18
-
-
77950581049
-
Photopatternable superhydrophobic nanocomposites for microfabrication
-
COI: 1:CAS:528:DC%2BC3cXlvFOhu7k%3D
-
Hong, L., and T. Pan. Photopatternable superhydrophobic nanocomposites for microfabrication. J Microelectromech. Syst. 19(2):246–253, 2010.
-
(2010)
J Microelectromech. Syst.
, vol.19
, Issue.2
, pp. 246-253
-
-
Hong, L.1
Pan, T.2
-
19
-
-
33645501361
-
Power-free sequential injection for microchip immunoassay toward point-of-care testing
-
PID: 16450033, COI: 1:CAS:528:DC%2BD28XptVygtA%3D%3D
-
Hosokawa, K., M. Omata, K. Sato, and M. Maeda. Power-free sequential injection for microchip immunoassay toward point-of-care testing. Lab Chip 6:236–241, 2006.
-
(2006)
Lab Chip
, vol.6
, pp. 236-241
-
-
Hosokawa, K.1
Omata, M.2
Sato, K.3
Maeda, M.4
-
20
-
-
77949798725
-
Multiplexed real-time polymerase chain reaction on a digital microfluidic platform
-
PID: 20151681, COI: 1:CAS:528:DC%2BC3cXhvFKjsrs%3D
-
Hua, Z. S., J. L. Rouse, A. E. Eckhardt, V. Srinivasan, V. K. Pamula, W. A. Schell, J. L. Benton, T. G. Mitchell, and M. G. Pollack. Multiplexed real-time polymerase chain reaction on a digital microfluidic platform. Anal. Chem. 82:2310–2316, 2010.
-
(2010)
Anal. Chem.
, vol.82
, pp. 2310-2316
-
-
Hua, Z.S.1
Rouse, J.L.2
Eckhardt, A.E.3
Srinivasan, V.4
Pamula, V.K.5
Schell, W.A.6
Benton, J.L.7
Mitchell, T.G.8
Pollack, M.G.9
-
21
-
-
0034332632
-
Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes
-
PID: 11080907, COI: 1:STN:280:DC%2BD3M%2FlslygsA%3D%3D
-
Huhmer, A. F. R., and J. P. Landers. Noncontact infrared-mediated thermocycling for effective polymerase chain reaction amplification of DNA in nanoliter volumes. Anal. Chem. 72:5507–5512, 2000.
-
(2000)
Anal. Chem.
, vol.72
, pp. 5507-5512
-
-
Huhmer, A.F.R.1
Landers, J.P.2
-
22
-
-
37349076149
-
Integrated circuit/microfluidic chip to programmably trap and move cells and droplets with dielectrophoresis
-
PID: 18094765, COI: 1:CAS:528:DC%2BD2sXhsVeltLbE
-
Hunt, T. P., D. Issadore, and R. M. Westervelt. Integrated circuit/microfluidic chip to programmably trap and move cells and droplets with dielectrophoresis. Lab Chip 8(1):81–87, 2008.
-
(2008)
Lab Chip
, vol.8
, Issue.1
, pp. 81-87
-
-
Hunt, T.P.1
Issadore, D.2
Westervelt, R.M.3
-
23
-
-
6944226383
-
Surface characterization of plasma-modified poly(ethylene terephthalate) film surfaces
-
COI: 1:CAS:528:DC%2BD2cXotlGrsr0%3D
-
Inagaki, N., K. Narushim, N. Tuchida, and K. Miyazaki. Surface characterization of plasma-modified poly(ethylene terephthalate) film surfaces. J. Polym. Sci. Part B 42:3727, 2004.
-
(2004)
J. Polym. Sci. Part B
, vol.42
, pp. 3727
-
-
Inagaki, N.1
Narushim, K.2
Tuchida, N.3
Miyazaki, K.4
-
24
-
-
67649335418
-
Microwave dielectric heating of drops in microfluidic devices
-
PID: 19495453, COI: 1:CAS:528:DC%2BD1MXms12itL4%3D
-
Issadore, D., K. J. Humphry, K. A. Brown, L. Sandberg, D. A. Weitz, and R. M. Westervelt. Microwave dielectric heating of drops in microfluidic devices. Lab Chip 9:1701–1706, 2009.
-
(2009)
Lab Chip
, vol.9
, pp. 1701-1706
-
-
Issadore, D.1
Humphry, K.J.2
Brown, K.A.3
Sandberg, L.4
Weitz, D.A.5
Westervelt, R.M.6
-
25
-
-
0032524099
-
Chemical amplification: continuous-flow PCR on a chip
-
PID: 9582111, COI: 1:CAS:528:DyaK1cXjt1aqtLg%3D
-
Kopp, M. U., A. J. de Mello, and A. Manz. Chemical amplification: continuous-flow PCR on a chip. Science 280(5366):1046–1048, 1998.
-
(1998)
Science
, vol.280
, Issue.5366
, pp. 1046-1048
-
-
Kopp, M.U.1
de Mello, A.J.2
Manz, A.3
-
26
-
-
33644746296
-
A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples
-
PID: 16503592, COI: 1:CAS:528:DC%2BD28XoslOjsQ%3D%3D
-
Legendre, L. A., J. M. Bienvenue, M. G. Roper, J. P. Ferrance, and J. P. Landers. A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples. Anal. Chem. 78(5):1444–1451, 2006.
-
(2006)
Anal. Chem.
, vol.78
, Issue.5
, pp. 1444-1451
-
-
Legendre, L.A.1
Bienvenue, J.M.2
Roper, M.G.3
Ferrance, J.P.4
Landers, J.P.5
-
27
-
-
33746216411
-
Droplet-based DNA purification in a magnetic Lab-on-a-Chip
-
COI: 1:CAS:528:DC%2BD28XkvFKnsLw%3D
-
Lehmann, U., C. Vandevyver, V. K. Parashar, and M. A. M. Gijs. Droplet-based DNA purification in a magnetic Lab-on-a-Chip. Angew. Chem. Int. Ed. 45(19):3062–3067, 2006.
-
(2006)
Angew. Chem. Int. Ed.
, vol.45
, Issue.19
, pp. 3062-3067
-
-
Lehmann, U.1
Vandevyver, C.2
Parashar, V.K.3
Gijs, M.A.M.4
-
28
-
-
0036079139
-
A nanoliter rotary device for polymerase chain reaction
-
PID: 12116165, COI: 1:CAS:528:DC%2BD38XksVWku78%3D
-
Liu, J., M. Enzelberger, and S. Quake. A nanoliter rotary device for polymerase chain reaction. Electrophoresis 23:1531–1536, 2002.
-
(2002)
Electrophoresis
, vol.23
, pp. 1531-1536
-
-
Liu, J.1
Enzelberger, M.2
Quake, S.3
-
29
-
-
66149107895
-
Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface
-
PID: 19458864, COI: 1:CAS:528:DC%2BD1MXmtFKgsb0%3D
-
Long, Z. C., A. M. Shetty, M. J. Solomon, and R. G. Larson. Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface. Lab Chip 9(11):1567–1575, 2009.
-
(2009)
Lab Chip
, vol.9
, Issue.11
, pp. 1567-1575
-
-
Long, Z.C.1
Shetty, A.M.2
Solomon, M.J.3
Larson, R.G.4
-
30
-
-
40049088179
-
A study of EWOD-driven droplets by PIV investigation
-
PID: 18305865, COI: 1:CAS:528:DC%2BD1cXisFSrs7k%3D
-
Lu, H. W., F. Bottausci, J. D. Fowler, A. L. Bertozzi, C. Meinhart, and C. J. Kim. A study of EWOD-driven droplets by PIV investigation. Lab Chip 8:456–461, 2008.
-
(2008)
Lab Chip
, vol.8
, pp. 456-461
-
-
Lu, H.W.1
Bottausci, F.2
Fowler, J.D.3
Bertozzi, A.L.4
Meinhart, C.5
Kim, C.J.6
-
31
-
-
84855298617
-
Design of hydrophobic surfaces for liquid droplet control
-
Nakajima, A. Design of hydrophobic surfaces for liquid droplet control. NPG Asia Mater. 3:49–56, 2011.
-
(2011)
NPG Asia Mater.
, vol.3
, pp. 49-56
-
-
Nakajima, A.1
-
32
-
-
33745097761
-
Disposable real-time microPCR device: lab-on-a-chip at a low cost
-
PID: 16880947, COI: 1:CAS:528:DC%2BD28XmvVams7k%3D
-
Neuzil, P., J. Pipper, and T. M. Hsieh. Disposable real-time microPCR device: lab-on-a-chip at a low cost. Mol. Biosyst. 2(6–7):292–298, 2006.
-
(2006)
Mol. Biosyst.
, vol.2
, Issue.6-7
, pp. 292-298
-
-
Neuzil, P.1
Pipper, J.2
Hsieh, T.M.3
-
33
-
-
33845742675
-
An integrated fluorescence detection system for lab-on-a-chip applications
-
PID: 17180202, COI: 1:CAS:528:DC%2BD28XhtlalurfK
-
Novak, L., P. Neuzil, J. Pipper, Y. Zhang, and S. Lee. An integrated fluorescence detection system for lab-on-a-chip applications. Lab Chip 7:27–29, 2007.
-
(2007)
Lab Chip
, vol.7
, pp. 27-29
-
-
Novak, L.1
Neuzil, P.2
Pipper, J.3
Zhang, Y.4
Lee, S.5
-
34
-
-
34548301688
-
A simple device using magnetic transportation for droplet-based PCR
-
COI: 1:CAS:528:DC%2BD2sXpsVaqt70%3D
-
Ohashi, T., H. Kuyama, N. Hanafusa, and Y. Togawa. A simple device using magnetic transportation for droplet-based PCR. Biomed. Microdev. 9:695–702, 2007.
-
(2007)
Biomed. Microdev.
, vol.9
, pp. 695-702
-
-
Ohashi, T.1
Kuyama, H.2
Hanafusa, N.3
Togawa, Y.4
-
35
-
-
72049103424
-
A light-induced dielectrophoretic droplet manipulation platform
-
PID: 19865729, COI: 1:CAS:528:DC%2BD1MXhtleitL3E
-
Park, S. Y., S. Kalim, C. Callahan, M. A. Teitell, and P. Y. Chiou. A light-induced dielectrophoretic droplet manipulation platform. Lab Chip 9(22):3228–3235, 2009.
-
(2009)
Lab Chip
, vol.9
, Issue.22
, pp. 3228-3235
-
-
Park, S.Y.1
Kalim, S.2
Callahan, C.3
Teitell, M.A.4
Chiou, P.Y.5
-
36
-
-
34948820188
-
Catching bird flu in a droplet
-
PID: 17891145, COI: 1:CAS:528:DC%2BD2sXhtFagsb3E
-
Pipper, J., M. Inoue, L. F. P. Ng, P. Neuzil, Y. Zhang, and L. Novak. Catching bird flu in a droplet. Nat. Med. 13(10):1259–1263, 2007.
-
(2007)
Nat. Med.
, vol.13
, Issue.10
, pp. 1259-1263
-
-
Pipper, J.1
Inoue, M.2
Ng, L.F.P.3
Neuzil, P.4
Zhang, Y.5
Novak, L.6
-
37
-
-
47049088924
-
Clockwork PCR including sample preparation
-
COI: 1:CAS:528:DC%2BD1cXmsVerurk%3D
-
Pipper, J., Y. Zhang, P. Neuzil, and T. M. Hsieh. Clockwork PCR including sample preparation. Angew. Chem. Int. Ed. 47(21):3900–3904, 2008.
-
(2008)
Angew. Chem. Int. Ed.
, vol.47
, Issue.21
, pp. 3900-3904
-
-
Pipper, J.1
Zhang, Y.2
Neuzil, P.3
Hsieh, T.M.4
-
38
-
-
79955761317
-
Applications of electrowetting-based digital microfluidics in clinical diagnostics
-
PID: 21545257, COI: 1:CAS:528:DC%2BC3MXlsF2ntL0%3D
-
Pollack, M. G., V. K. Pamula, V. Srinivasan, and A. E. Eckhardt. Applications of electrowetting-based digital microfluidics in clinical diagnostics. Expert Rev. Mol. Diagn. 11(4):393–407, 2011.
-
(2011)
Expert Rev. Mol. Diagn.
, vol.11
, Issue.4
, pp. 393-407
-
-
Pollack, M.G.1
Pamula, V.K.2
Srinivasan, V.3
Eckhardt, A.E.4
-
39
-
-
0142121691
-
Long-range transport of magnetic microbeads using simple planar coils placed in a uniform magnetostatic field
-
COI: 1:CAS:528:DC%2BD3sXnsVWhs7g%3D
-
Rida, A., V. Fernandez, and M. A. M. Gijs. Long-range transport of magnetic microbeads using simple planar coils placed in a uniform magnetostatic field. Appl. Phys. Lett. 83(12):2396, 2003.
-
(2003)
Appl. Phys. Lett.
, vol.83
, Issue.12
, pp. 2396
-
-
Rida, A.1
Fernandez, V.2
Gijs, M.A.M.3
-
40
-
-
0023753018
-
Diagnosis of sickle cell anemia and beta-thalassemia with enzymatically amplified DNA and nonradioactive allele-specific oligonucleotide probes
-
PID: 3405266, COI: 1:CAS:528:DyaL1cXmt1Gqu7g%3D
-
Saiki, R. K., C. A. Chang, C. H. Levenson, T. C. Warren, C. D. Boehm, H. H. Kazazian, and H. A. Erlich. Diagnosis of sickle cell anemia and beta-thalassemia with enzymatically amplified DNA and nonradioactive allele-specific oligonucleotide probes. N. Engl. J. Med. 319:537–541, 1988.
-
(1988)
N. Engl. J. Med.
, vol.319
, pp. 537-541
-
-
Saiki, R.K.1
Chang, C.A.2
Levenson, C.H.3
Warren, T.C.4
Boehm, C.D.5
Kazazian, H.H.6
Erlich, H.A.7
-
41
-
-
84870954981
-
Surface tension confined (STC) tracks for capillary-driven transport of low surface tension liquids
-
PID: 23117534, COI: 1:CAS:528:DC%2BC38XhvVSmu7vM
-
Schutzius, T. M., M. Elsharkawy, M. K. Tiwari, and C. M. Megaridis. Surface tension confined (STC) tracks for capillary-driven transport of low surface tension liquids. Lab Chip 12:5237–5242, 2012.
-
(2012)
Lab Chip
, vol.12
, pp. 5237-5242
-
-
Schutzius, T.M.1
Elsharkawy, M.2
Tiwari, M.K.3
Megaridis, C.M.4
-
42
-
-
34748830262
-
The force acting on a superparamagnetic bead due to an applied magnetic field
-
PID: 17896013, COI: 1:CAS:528:DC%2BD2sXhtVOrtL%2FN
-
Shevkoplyas, S. S., A. C. Siegel, R. M. Westervelt, M. G. Prentiss, and G. M. Whitesides. The force acting on a superparamagnetic bead due to an applied magnetic field. Lab Chip 7(10):1294–1302, 2007.
-
(2007)
Lab Chip
, vol.7
, Issue.10
, pp. 1294-1302
-
-
Shevkoplyas, S.S.1
Siegel, A.C.2
Westervelt, R.M.3
Prentiss, M.G.4
Whitesides, G.M.5
-
43
-
-
42549158967
-
A palmtop-sized rotary-drive-type biochemical analysis system by magnetic bead handling
-
Shikida, M., N. Nagao, R. Imai, H. Honda, M. Okochi, H. Ito, and K. Sato. A palmtop-sized rotary-drive-type biochemical analysis system by magnetic bead handling. J. Micromech. Microeng. 18:35034–35041, 2008.
-
(2008)
J. Micromech. Microeng.
, vol.18
, pp. 35034-35041
-
-
Shikida, M.1
Nagao, N.2
Imai, R.3
Honda, H.4
Okochi, M.5
Ito, H.6
Sato, K.7
-
44
-
-
29244476851
-
Using wettability and interfacial tension to handle droplets of magnetic beads in a micro-chemical-analysis system
-
COI: 1:CAS:528:DC%2BD2MXhtlCrsrvM
-
Shikida, M., K. Takayanagi, K. Inouchi, H. Honda, and K. Sato. Using wettability and interfacial tension to handle droplets of magnetic beads in a micro-chemical-analysis system. Sens. Actuators B 113(1):563–569, 2006.
-
(2006)
Sens. Actuators B
, vol.113
, Issue.1
, pp. 563-569
-
-
Shikida, M.1
Takayanagi, K.2
Inouchi, K.3
Honda, H.4
Sato, K.5
-
45
-
-
84904789133
-
-
Zhang: T. H. Wang. A droplet microfluidic approach to single-stream nucleic acid isolation and mutation detection
-
Shin, D. J., Y. Zhang, T. H. Wang. A droplet microfluidic approach to single-stream nucleic acid isolation and mutation detection. Microfluid Nanofluid. 2014. doi:10.1007/s10404-013-1305-7.
-
(2014)
Microfluid Nanofluid
-
-
Shin, D.J.1
-
46
-
-
77956274928
-
Stabilization of proteins for storage
-
Simpson, R. J. Stabilization of proteins for storage. Cold Spring Harb. Protoc. 5:pdb.top79, 2010.
-
(2010)
Cold Spring Harb. Protoc.
, vol.5
-
-
Simpson, R.J.1
-
47
-
-
56549119892
-
Development of a digital microfluidic platform for point of care testing
-
PID: 19023472, COI: 1:CAS:528:DC%2BD1cXhsVSgtbnO
-
Sista, R., Z. Hua, A. Sudarsan, V. Srinivasan, A. Eckhardt, M. G. Pollack, and V. K. Pamula. Development of a digital microfluidic platform for point of care testing. Lab Chip 8(12):2091–2104, 2008.
-
(2008)
Lab Chip
, vol.8
, Issue.12
, pp. 2091-2104
-
-
Sista, R.1
Hua, Z.2
Sudarsan, A.3
Srinivasan, V.4
Eckhardt, A.5
Pollack, M.G.6
Pamula, V.K.7
-
48
-
-
4344632455
-
An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids
-
PID: 15269796, COI: 1:CAS:528:DC%2BD2cXlvVKms7c%3D
-
Srinivasan, V., V. K. Pamula, and R. B. Fair. An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. Lab Chip 4(4):310–315, 2004.
-
(2004)
Lab Chip
, vol.4
, Issue.4
, pp. 310-315
-
-
Srinivasan, V.1
Pamula, V.K.2
Fair, R.B.3
-
49
-
-
0030710491
-
Molecular diagnostics of infectious diseases
-
PID: 9365385, COI: 1:CAS:528:DyaK2sXnt1ejs70%3D
-
Tang, Y. W., G. W. Procop, and D. H. Persing. Molecular diagnostics of infectious diseases. Clin. Chem. 43(11):2021–2038, 1997.
-
(1997)
Clin. Chem.
, vol.43
, Issue.11
, pp. 2021-2038
-
-
Tang, Y.W.1
Procop, G.W.2
Persing, D.H.3
-
50
-
-
84902499171
-
SiOC as a hydrophobic layer for electrowetting on dielectric applications. Proceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences
-
Thery, J., M. Borella, S. Le Vot, D. Jary, F. Rivera, G. Castellan, A. G. Brachet, M. Plissonnier, Y. Fouillet. SiOC as a hydrophobic layer for electrowetting on dielectric applications. Proceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences, Paris, 7–11 October 2007. vol. 1, pp. 349–351.
-
Paris, 7–11
, vol.1
, pp. 349-351
-
-
Thery, J.1
Borella, M.2
Le Vot, S.3
Jary, D.4
Rivera, F.5
Castellan, G.6
Brachet, A.G.7
Plissonnier, M.8
Fouillet, Y.9
-
51
-
-
77954380684
-
Comparison of Sanger sequencing, pyrosequencing, and melting curve analysis for the detection of KRAS mutations: diagnostic and clinical implications
-
PID: 20431034, COI: 1:CAS:528:DC%2BC3cXhtVehurrO
-
Tsiatis, A. C., A. Norris-Kirby, R. G. Rich, M. J. Hafez, C. D. Gocke, J. R. Eshleman, and K. M. Murphy. Comparison of Sanger sequencing, pyrosequencing, and melting curve analysis for the detection of KRAS mutations: diagnostic and clinical implications. J. Mol. Diagn. 12(4):425–432, 2010.
-
(2010)
J. Mol. Diagn.
, vol.12
, Issue.4
, pp. 425-432
-
-
Tsiatis, A.C.1
Norris-Kirby, A.2
Rich, R.G.3
Hafez, M.J.4
Gocke, C.D.5
Eshleman, J.R.6
Murphy, K.M.7
-
52
-
-
40949098675
-
On-chip polymerase chain reaction microdevice employing a magnetic droplet-manipulation system
-
COI: 1:CAS:528:DC%2BD1cXjs1amtLw%3D
-
Tsuchiya, H., M. Okochi, N. Nagao, M. Shikida, and H. Honda. On-chip polymerase chain reaction microdevice employing a magnetic droplet-manipulation system. Sens Actuators B 130(2):583–588, 2008.
-
(2008)
Sens Actuators B
, vol.130
, Issue.2
, pp. 583-588
-
-
Tsuchiya, H.1
Okochi, M.2
Nagao, N.3
Shikida, M.4
Honda, H.5
-
53
-
-
0346874344
-
On-chip manipulation of free droplets
-
PID: 14654830, COI: 1:CAS:528:DC%2BD3sXpsVejsLc%3D
-
Velev, O. D., B. G. Prevo, and K. H. Bhatt. On-chip manipulation of free droplets. Nature 426(6966):515–516, 2003.
-
(2003)
Nature
, vol.426
, Issue.6966
, pp. 515-516
-
-
Velev, O.D.1
Prevo, B.G.2
Bhatt, K.H.3
-
54
-
-
0000822783
-
Preparative and analytical purification of DNA from agarose
-
PID: 284385, COI: 1:CAS:528:DyaE1MXhsVOqt7w%3D
-
Vogelstein, B., and D. Gillespie. Preparative and analytical purification of DNA from agarose. Proc. Natl. Acad. Sci. USA 76:615–619, 1979.
-
(1979)
Proc. Natl. Acad. Sci. USA
, vol.76
, pp. 615-619
-
-
Vogelstein, B.1
Gillespie, D.2
-
55
-
-
79551636514
-
Picoliter DNA sequencing chemistry on an electrowetting-based digital microfluidic platform
-
PID: 21298802, COI: 1:CAS:528:DC%2BC3MXhsFGksL4%3D
-
Welch, E. R., Y. Y. Lin, A. Madison, and R. B. Fair. Picoliter DNA sequencing chemistry on an electrowetting-based digital microfluidic platform. Biotechnol. J. 6(2):165–176, 2011.
-
(2011)
Biotechnol. J.
, vol.6
, Issue.2
, pp. 165-176
-
-
Welch, E.R.1
Lin, Y.Y.2
Madison, A.3
Fair, R.B.4
-
56
-
-
0038359432
-
High-resolution genotyping by amplicon melting analysis using LCGreen
-
PID: 12765979, COI: 1:CAS:528:DC%2BD3sXkt1Oms7Y%3D
-
Wittwer, C. T., G. H. Reed, C. N. Gundry, J. G. Vanderstenn, and R. J. Pryor. High-resolution genotyping by amplicon melting analysis using LCGreen. Clin. Chem. 49(6):853–860, 2003.
-
(2003)
Clin. Chem.
, vol.49
, Issue.6
, pp. 853-860
-
-
Wittwer, C.T.1
Reed, G.H.2
Gundry, C.N.3
Vanderstenn, J.G.4
Pryor, R.J.5
-
57
-
-
0002713231
-
Allele-specific enzymatic amplification of beta-globin genomic DNA for diagnosis of sickle cell anemia
-
PID: 2704745, COI: 1:CAS:528:DyaL1MXktlKjs7k%3D
-
Wu, D. Y., L. Ugozzoli, B. K. Pal, and R. B. Wallace. Allele-specific enzymatic amplification of beta-globin genomic DNA for diagnosis of sickle cell anemia. Proc. Natl. Acad. Sci. USA 86(8):2757–2760, 1989.
-
(1989)
Proc. Natl. Acad. Sci. USA
, vol.86
, Issue.8
, pp. 2757-2760
-
-
Wu, D.Y.1
Ugozzoli, L.2
Pal, B.K.3
Wallace, R.B.4
-
58
-
-
0031947320
-
Soft lithography
-
COI: 1:CAS:528:DyaK1cXitleltbs%3D
-
Xia, Y., and G. M. Whitesides. Soft lithography. Angew. Chem. Int. Ed. 37(5):550–575, 1998.
-
(1998)
Angew. Chem. Int. Ed.
, vol.37
, Issue.5
, pp. 550-575
-
-
Xia, Y.1
Whitesides, G.M.2
-
59
-
-
33645220585
-
Real time PCR on disposable PDMS chip with a miniaturized thermal cycler
-
COI: 1:CAS:528:DC%2BD28XjtVygsA%3D%3D
-
Xiang, Q., B. Xu, R. Fu, and D. Li. Real time PCR on disposable PDMS chip with a miniaturized thermal cycler. Biomed. Microdev. 7(4):273–279, 2005.
-
(2005)
Biomed. Microdev.
, vol.7
, Issue.4
, pp. 273-279
-
-
Xiang, Q.1
Xu, B.2
Fu, R.3
Li, D.4
-
60
-
-
80054012763
-
Droplet-driven transports on superhydrophobic-patterned surface microfluidics
-
PID: 21918770, COI: 1:CAS:528:DC%2BC3MXht12ju7nE
-
Xing, S., R. S. Harake, and T. Pan. Droplet-driven transports on superhydrophobic-patterned surface microfluidics. Lab Chip 11:3642–3648, 2011.
-
(2011)
Lab Chip
, vol.11
, pp. 3642-3648
-
-
Xing, S.1
Harake, R.S.2
Pan, T.3
-
61
-
-
84878101085
-
Paper-based microfluidic point-of-care diagnostic devices
-
PID: 23652632, COI: 1:CAS:528:DC%2BC3sXnvV2ns7s%3D
-
Yetisen, A. K., M. S. Akram, and C. R. Lowe. Paper-based microfluidic point-of-care diagnostic devices. Lab Chip 13:2210–2251, 2013.
-
(2013)
Lab Chip
, vol.13
, pp. 2210-2251
-
-
Yetisen, A.K.1
Akram, M.S.2
Lowe, C.R.3
-
62
-
-
82455220464
-
Evaluation of the GeneXpert MTB/RIF assay for rapid diagnosis of tuberculosis and detection of rifampin resistance in pulmonary and extrapulmonary specimens
-
PID: 21956978
-
Zeka, A. N., S. Tasbakan, and C. Cavusoglu. Evaluation of the GeneXpert MTB/RIF assay for rapid diagnosis of tuberculosis and detection of rifampin resistance in pulmonary and extrapulmonary specimens. J. Clin. Microbiol. 49(12):4138–4141, 2011.
-
(2011)
J. Clin. Microbiol.
, vol.49
, Issue.12
, pp. 4138-4141
-
-
Zeka, A.N.1
Tasbakan, S.2
Cavusoglu, C.3
-
63
-
-
78751540409
-
A surface topography assisted droplet manipulation platform for biomarker detection and pathogen identification
-
PID: 21046055, COI: 1:CAS:528:DC%2BC3MXmsVOhsQ%3D%3D
-
Zhang, Y., S. Park, K. Liu, J. Tsuan, S. Yang, and T. H. Wang. A surface topography assisted droplet manipulation platform for biomarker detection and pathogen identification. Lab Chip 11(3):398–406, 2011.
-
(2011)
Lab Chip
, vol.11
, Issue.3
, pp. 398-406
-
-
Zhang, Y.1
Park, S.2
Liu, K.3
Tsuan, J.4
Yang, S.5
Wang, T.H.6
-
64
-
-
78049265212
-
An all-in-one microfluidic device for parallel DNA extraction and gene analysis
-
COI: 1:CAS:528:DC%2BC3cXhtlSgsb3J
-
Zhang, Y., S. Park, S. Yang, and T. H. Wang. An all-in-one microfluidic device for parallel DNA extraction and gene analysis. Biomed. Microdev. 12(6):1043–1049, 2010.
-
(2010)
Biomed. Microdev.
, vol.12
, Issue.6
, pp. 1043-1049
-
-
Zhang, Y.1
Park, S.2
Yang, S.3
Wang, T.H.4
-
65
-
-
84887556751
-
Serial dilution via surface energy trap-assisted magnetic droplet manipulation
-
PID: 24162777, COI: 1:CAS:528:DC%2BC3sXhslGgsLvO
-
Zhang, Y., D. J. Shin, and T. H. Wang. Serial dilution via surface energy trap-assisted magnetic droplet manipulation. Lab Chip 13:4827–4831, 2013.
-
(2013)
Lab Chip
, vol.13
, pp. 4827-4831
-
-
Zhang, Y.1
Shin, D.J.2
Wang, T.H.3
-
66
-
-
84860841983
-
Micro magnetic Gyromixer for speeding up reactions in droplets
-
PID: 22707926, COI: 1:CAS:528:DC%2BC38XivFWksL4%3D
-
Zhang, Y., and T. H. Wang. Micro magnetic Gyromixer for speeding up reactions in droplets. Microfluid Nanofluid 12(5):787–794, 2012.
-
(2012)
Microfluid Nanofluid
, vol.12
, Issue.5
, pp. 787-794
-
-
Zhang, Y.1
Wang, T.H.2
-
67
-
-
84878550372
-
Full-range magnetic manipulation of droplets via surface energy traps enables complex bioassays
-
COI: 1:CAS:528:DC%2BC3sXksFansrk%3D
-
Zhang, Y., and T. H. Wang. Full-range magnetic manipulation of droplets via surface energy traps enables complex bioassays. Adv. Mater. 25:2903–2908, 2013.
-
(2013)
Adv. Mater.
, vol.25
, pp. 2903-2908
-
-
Zhang, Y.1
Wang, T.H.2
|