메뉴 건너뛰기




Volumn 102, Issue , 2015, Pages 1-9

A novel third generation uric acid biosensor using uricase electro-activated with ferrocene on a Nafion coated glassy carbon electrode

Author keywords

Biosensor; Cyclic voltammetry; Differential pulse voltammetry; Ferrocene; Uric acid; Uricase

Indexed keywords

BIOSENSORS; CARBON; CHARGE TRANSFER; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; ENZYMES; FLUORESCENCE SPECTROSCOPY; FOURIER TRANSFORM INFRARED SPECTROSCOPY; GLASS; GLASS MEMBRANE ELECTRODES; GLASSY CARBON; ORGANIC ACIDS; ORGANOMETALLICS; RATE CONSTANTS;

EID: 84919399756     PISSN: 15675394     EISSN: 1878562X     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2014.11.001     Document Type: Article
Times cited : (94)

References (40)
  • 3
    • 70350614305 scopus 로고    scopus 로고
    • Calcium oxalate stone and gout
    • Marickar Y.M. Calcium oxalate stone and gout. Urol. Res. 2009, 37:345-347.
    • (2009) Urol. Res. , vol.37 , pp. 345-347
    • Marickar, Y.M.1
  • 7
    • 2442580884 scopus 로고    scopus 로고
    • Polyaniline-uricase biosensor prepared with template process
    • Kan J., Pan X., Chen C. Polyaniline-uricase biosensor prepared with template process. Biosens. Bioelectron. 2004, 19:1635-1640.
    • (2004) Biosens. Bioelectron. , vol.19 , pp. 1635-1640
    • Kan, J.1    Pan, X.2    Chen, C.3
  • 8
    • 77954907846 scopus 로고    scopus 로고
    • Direct determination of uric acid in human serum samples using polypyrrole nanoelectrode ensembles
    • Yang G., Tan L., Shi Y., Wang S., Lu X., Bai H., Yang Y. Direct determination of uric acid in human serum samples using polypyrrole nanoelectrode ensembles. Bull. Kor. Chem. Soc. 2009, 30:454-458.
    • (2009) Bull. Kor. Chem. Soc. , vol.30 , pp. 454-458
    • Yang, G.1    Tan, L.2    Shi, Y.3    Wang, S.4    Lu, X.5    Bai, H.6    Yang, Y.7
  • 10
    • 84858990145 scopus 로고    scopus 로고
    • A potentiometric indirect uric acid sensor based on ZnO nanoflakes and immobilized uricase
    • Usman Ali M.S., Ibupoto Z.H., Kashif M., Hashim U., Willander M. A potentiometric indirect uric acid sensor based on ZnO nanoflakes and immobilized uricase. Sensors 2012, 12:2787-2797.
    • (2012) Sensors , vol.12 , pp. 2787-2797
    • Usman Ali, M.S.1    Ibupoto, Z.H.2    Kashif, M.3    Hashim, U.4    Willander, M.5
  • 11
    • 84864390207 scopus 로고    scopus 로고
    • CuO thin film based uric acid biosensor with enhanced response characteristics
    • Jindal K., Tomar M., Gupta V. CuO thin film based uric acid biosensor with enhanced response characteristics. Biosens. Bioelectron. 2012, 38:11-18.
    • (2012) Biosens. Bioelectron. , vol.38 , pp. 11-18
    • Jindal, K.1    Tomar, M.2    Gupta, V.3
  • 12
    • 84862658645 scopus 로고    scopus 로고
    • A glassy carbon electrode modified with grapheme and poly(acridine red) for sensing uric acid
    • Li Y., Ran G., Yi W.J., Luo H.Q., Li N.B. A glassy carbon electrode modified with grapheme and poly(acridine red) for sensing uric acid. Microchim. Acta 2012, 178:115-121.
    • (2012) Microchim. Acta , vol.178 , pp. 115-121
    • Li, Y.1    Ran, G.2    Yi, W.J.3    Luo, H.Q.4    Li, N.B.5
  • 13
    • 84858276004 scopus 로고    scopus 로고
    • Simultaneous electrochemical sensing of ascorbic acid, dopamine and uric acid at anodized nanocrystalline graphite-like pyrolytic carbon film electrode
    • Hadi M., Rouhollahi A. Simultaneous electrochemical sensing of ascorbic acid, dopamine and uric acid at anodized nanocrystalline graphite-like pyrolytic carbon film electrode. Anal. Chim. Acta 2012, 721:55-60.
    • (2012) Anal. Chim. Acta , vol.721 , pp. 55-60
    • Hadi, M.1    Rouhollahi, A.2
  • 14
    • 0036742401 scopus 로고    scopus 로고
    • Chemiluminescence biosensor chip based on a microreactor using carrier air flow for determination of uric acid in human serum
    • Lv Y., Zhang Z., Chen F. Chemiluminescence biosensor chip based on a microreactor using carrier air flow for determination of uric acid in human serum. Analyst 2002, 127:1176-1179.
    • (2002) Analyst , vol.127 , pp. 1176-1179
    • Lv, Y.1    Zhang, Z.2    Chen, F.3
  • 16
    • 0026523045 scopus 로고
    • Amperometric glucose sensor with ferrocene as an electron transfer mediator
    • Dong S., Wang B., Liu B. Amperometric glucose sensor with ferrocene as an electron transfer mediator. Biosens. Bioelectron. 1991, 7:215-222.
    • (1991) Biosens. Bioelectron. , vol.7 , pp. 215-222
    • Dong, S.1    Wang, B.2    Liu, B.3
  • 17
    • 84890867361 scopus 로고    scopus 로고
    • A novel amperometric alcohol biosensor developed in a 3rd generation bioelectrode platform using peroxidase coupled ferrocene activated alcohol oxidase as biorecognition system
    • Chinnadayyala S.R., Kakoti A., Santhosh M., Goswami P. A novel amperometric alcohol biosensor developed in a 3rd generation bioelectrode platform using peroxidase coupled ferrocene activated alcohol oxidase as biorecognition system. Biosens. Bioelectron. 2014, 55:120-126.
    • (2014) Biosens. Bioelectron. , vol.55 , pp. 120-126
    • Chinnadayyala, S.R.1    Kakoti, A.2    Santhosh, M.3    Goswami, P.4
  • 21
    • 0010448437 scopus 로고    scopus 로고
    • An amperometric enzyme electrode for glucose by immobilizing glucose oxidase and ferrocene in β-cyclodextrin
    • Liu S.H., Mo W.M., Chen F. An amperometric enzyme electrode for glucose by immobilizing glucose oxidase and ferrocene in β-cyclodextrin. J. Instrum. Anal. 1999, 18:42-45.
    • (1999) J. Instrum. Anal. , vol.18 , pp. 42-45
    • Liu, S.H.1    Mo, W.M.2    Chen, F.3
  • 22
    • 0034724820 scopus 로고    scopus 로고
    • β-Cyclodextrin-ferrocene inclusion complex modified carbon paste electrode for amperometric determination of ascorbic acid
    • Zhang G.R., Wang X.L., Shi X.W., Sun T.L. β-Cyclodextrin-ferrocene inclusion complex modified carbon paste electrode for amperometric determination of ascorbic acid. Talanta 2000, 51:1019-1025.
    • (2000) Talanta , vol.51 , pp. 1019-1025
    • Zhang, G.R.1    Wang, X.L.2    Shi, X.W.3    Sun, T.L.4
  • 23
    • 1642559666 scopus 로고    scopus 로고
    • Differential pulse voltammetry determination of ascorbic acid with ferrocene-l-cysteine self-assembled supramolecular film modified electrode
    • Wang S., Du D. Differential pulse voltammetry determination of ascorbic acid with ferrocene-l-cysteine self-assembled supramolecular film modified electrode. Sensors Actuators B 2004, 97:373-378.
    • (2004) Sensors Actuators B , vol.97 , pp. 373-378
    • Wang, S.1    Du, D.2
  • 24
    • 35448929099 scopus 로고    scopus 로고
    • 2 magnetic nanoparticles as building blocks for construction of reagentless enzyme-based biosensors
    • 2 magnetic nanoparticles as building blocks for construction of reagentless enzyme-based biosensors. Electrochem. Commun. 2007, 9:2734-2738.
    • (2007) Electrochem. Commun. , vol.9 , pp. 2734-2738
    • Qiu, J.D.1    Peng, H.P.2    Liang, R.P.3
  • 25
    • 68949120956 scopus 로고    scopus 로고
    • Selective amperometric sensing of hydrogen peroxide with nafion/copper particulates chemically modified electrode
    • Senthil Kumar A., Sornambikai S. Selective amperometric sensing of hydrogen peroxide with nafion/copper particulates chemically modified electrode. Indian J. Chem. 2009, 48:940-945.
    • (2009) Indian J. Chem. , vol.48 , pp. 940-945
    • Senthil Kumar, A.1    Sornambikai, S.2
  • 26
    • 61649100824 scopus 로고    scopus 로고
    • Study on a pyruvate oxidase biosensor based on β-cyclodextrin with ferrocene as electron-transfer mediator
    • Yumei L., Zhiqiang F., Kejun D., Yifeng T. Study on a pyruvate oxidase biosensor based on β-cyclodextrin with ferrocene as electron-transfer mediator. Anal. Lett. 2009, 42:312-322.
    • (2009) Anal. Lett. , vol.42 , pp. 312-322
    • Yumei, L.1    Zhiqiang, F.2    Kejun, D.3    Yifeng, T.4
  • 27
    • 80052134873 scopus 로고    scopus 로고
    • Fabrication of GNPs/CDSH-Fc/nafion modified electrode for the detection of dopamine in the presence of ascorbic acid
    • Chen M., Wei X., Qian H., Diao G. Fabrication of GNPs/CDSH-Fc/nafion modified electrode for the detection of dopamine in the presence of ascorbic acid. Mater. Sci. Eng. C 2011, 31:1271-1277.
    • (2011) Mater. Sci. Eng. C , vol.31 , pp. 1271-1277
    • Chen, M.1    Wei, X.2    Qian, H.3    Diao, G.4
  • 28
    • 84879884033 scopus 로고    scopus 로고
    • Highly sensitive uric acid biosensor based on individual zinc oxide micro/nanowires
    • Zhao Y., Yan X., Kang Z., Lin P., Fang X., Lei Y., Ma S., Zhang Y. Highly sensitive uric acid biosensor based on individual zinc oxide micro/nanowires. Microchim. Acta 2013, 180:759-766.
    • (2013) Microchim. Acta , vol.180 , pp. 759-766
    • Zhao, Y.1    Yan, X.2    Kang, Z.3    Lin, P.4    Fang, X.5    Lei, Y.6    Ma, S.7    Zhang, Y.8
  • 29
    • 84866282785 scopus 로고    scopus 로고
    • Direct electrochemistry of alcohol oxidase using multiwalled carbon nanotube as electroactive matrix for biosensor application
    • Das M., Goswami P. Direct electrochemistry of alcohol oxidase using multiwalled carbon nanotube as electroactive matrix for biosensor application. Bioelectrochemistry 2013, 89:19-25.
    • (2013) Bioelectrochemistry , vol.89 , pp. 19-25
    • Das, M.1    Goswami, P.2
  • 30
    • 84922104065 scopus 로고    scopus 로고
    • Isolation of a novel uric acid degrading microbe Comamonas sp. BT UA and rapid biosensing of uric acid from extracted uricase enzyme
    • Ghosh T., Sarkar P. Isolation of a novel uric acid degrading microbe Comamonas sp. BT UA and rapid biosensing of uric acid from extracted uricase enzyme. J. Biosci 2014, 39:805-819.
    • (2014) J. Biosci , vol.39 , pp. 805-819
    • Ghosh, T.1    Sarkar, P.2
  • 31
    • 84919358317 scopus 로고    scopus 로고
    • Electrochemical behavior of vanadium in azide electrolyte in comparison with the behavior in halogen ions-containing electrolytes
    • Ghoneim A.A. Electrochemical behavior of vanadium in azide electrolyte in comparison with the behavior in halogen ions-containing electrolytes. Open Electrochem. J. 2009, 1:42-48.
    • (2009) Open Electrochem. J. , vol.1 , pp. 42-48
    • Ghoneim, A.A.1
  • 33
    • 84919358316 scopus 로고    scopus 로고
    • The Sadtler Standard Spectra, Standard Infrared Grating Spectra, ©1973 Sadtler Research Laboratories Inc., Subsidiary of Block Engineering Inc., 28121K.
    • The Sadtler Standard Spectra, Standard Infrared Grating Spectra, ©1973 Sadtler Research Laboratories Inc., Subsidiary of Block Engineering Inc., 28121K.
  • 34
    • 68149142267 scopus 로고    scopus 로고
    • Application of mesoporous carbon to counter electrode for dye-sensitized solar cells
    • Wang G., Xing W., Zhuo S. Application of mesoporous carbon to counter electrode for dye-sensitized solar cells. J. Power Sources 2009, 194:568-573.
    • (2009) J. Power Sources , vol.194 , pp. 568-573
    • Wang, G.1    Xing, W.2    Zhuo, S.3
  • 35
    • 84889995114 scopus 로고    scopus 로고
    • (4-Ferrocenylethyne) phenylamine functionalized graphene oxide modified electrode for sensitive nitrite sensing
    • Liu M., Wang L., Meng Y., Chen Q., Li H., Zhang Y., Yao S. (4-Ferrocenylethyne) phenylamine functionalized graphene oxide modified electrode for sensitive nitrite sensing. Electrochim. Acta 2014, 116:504-511.
    • (2014) Electrochim. Acta , vol.116 , pp. 504-511
    • Liu, M.1    Wang, L.2    Meng, Y.3    Chen, Q.4    Li, H.5    Zhang, Y.6    Yao, S.7
  • 37
    • 0042346238 scopus 로고    scopus 로고
    • Electrochemical tagging of urate: developing new redox probes
    • Dutt J.S.N., Cardosi M.F., Davis J. Electrochemical tagging of urate: developing new redox probes. Analyst 2003, 128:811-813.
    • (2003) Analyst , vol.128 , pp. 811-813
    • Dutt, J.S.N.1    Cardosi, M.F.2    Davis, J.3
  • 38
    • 84865696991 scopus 로고    scopus 로고
    • Highly sensitive and selective dopamine biosensor based on a phenylethynyl ferrocene/graphene nanocomposite modified electrode
    • Liu M., Wang L., Deng J., Chen Q., Li Y., Zhang Y., Li H., Yao S. Highly sensitive and selective dopamine biosensor based on a phenylethynyl ferrocene/graphene nanocomposite modified electrode. Analyst 2012, 137:4577-4583.
    • (2012) Analyst , vol.137 , pp. 4577-4583
    • Liu, M.1    Wang, L.2    Deng, J.3    Chen, Q.4    Li, Y.5    Zhang, Y.6    Li, H.7    Yao, S.8
  • 39
    • 0347833190 scopus 로고    scopus 로고
    • Determination of standard rate constants for electrochemical irreversible processes from linear sweep voltammograms
    • Velasco J.G. Determination of standard rate constants for electrochemical irreversible processes from linear sweep voltammograms. Electroanalysis 1997, 9:880-882.
    • (1997) Electroanalysis , vol.9 , pp. 880-882
    • Velasco, J.G.1
  • 40
    • 84860543366 scopus 로고    scopus 로고
    • Amperometric biosensor based on diamond paste for the enantioanalysis of l-lysine
    • Staden R.S., Nejem R.M., Staden J.F., Aboul-Enein H.Y. Amperometric biosensor based on diamond paste for the enantioanalysis of l-lysine. Biosens. Bioelectron. 2012, 35:439-442.
    • (2012) Biosens. Bioelectron. , vol.35 , pp. 439-442
    • Staden, R.S.1    Nejem, R.M.2    Staden, J.F.3    Aboul-Enein, H.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.