메뉴 건너뛰기




Volumn 41, Issue 1, 2015, Pages 52-59

Simultaneous MRI of lung structure and perfusion in a single breathhold

Author keywords

3D radial UTE for lung imaging; Pulmonary perfusion; Vascular structure

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CONTRAST ENHANCEMENT; EXPERIMENTAL DOG; FEMALE; IMAGE PROCESSING; IMAGE RECONSTRUCTION; LUNG PARENCHYMA; LUNG PERFUSION; LUNG SCINTISCANNING; LUNG STRUCTURE; MALE; NOISE REDUCTION; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PULMONARY ARTERY; RESPIRATORY GATED IMAGING; THREE DIMENSIONAL IMAGING; TISSUE DIFFERENTIATION; ANATOMY AND HISTOLOGY; ANIMAL; BREATH HOLDING; DOG; IMAGE ENHANCEMENT; LUNG; PROCEDURES; VASCULARIZATION;

EID: 84919345825     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24520     Document Type: Article
Times cited : (23)

References (27)
  • 1
    • 12544251237 scopus 로고    scopus 로고
    • Lung MRI at 3.0 T: A comparison of helical CT and high-field MRI in the detection of diffuse lung disease
    • Lutterbey G, Gieseke J, von Falkenhausen M, Morakkabati N, Schild H. Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease. Eur Radiol 2005;15:324-328.
    • (2005) Eur Radiol , vol.15 , pp. 324-328
    • Lutterbey, G.1    Gieseke, J.2    Von Falkenhausen, M.3    Morakkabati, N.4    Schild, H.5
  • 2
    • 0033013455 scopus 로고    scopus 로고
    • MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence
    • Hatabu H, Gaa J, Tadamura E, et al. MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 1999;29:152-159.
    • (1999) Eur J Radiol , vol.29 , pp. 152-159
    • Hatabu, H.1    Gaa, J.2    Tadamura, E.3
  • 3
    • 34250345248 scopus 로고    scopus 로고
    • Short data-acquisition times improve projection images of lung tissue
    • Kuethe DO, Adolphi NL, Fukushima E. Short data-acquisition times improve projection images of lung tissue. Magn Reson Med 2007;57:1058-1064.
    • (2007) Magn Reson Med , vol.57 , pp. 1058-1064
    • Kuethe, D.O.1    Adolphi, N.L.2    Fukushima, E.3
  • 4
    • 78349261177 scopus 로고    scopus 로고
    • Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma
    • Togao O, Tsuji R, Ohno Y, Dimitrov I, Takahashi M. Ultrashort echo time (UTE) MRI of the lung: assessment of tissue density in the lung parenchyma. Magn Reson Med 2010;64:1491-1498.
    • (2010) Magn Reson Med , vol.64 , pp. 1491-1498
    • Togao, O.1    Tsuji, R.2    Ohno, Y.3    Dimitrov, I.4    Takahashi, M.5
  • 5
    • 77955116866 scopus 로고    scopus 로고
    • Validation of simple and robust protocols for high-resolution lung proton MRI in mice
    • Zurek M, Bessaad A, Cieslar K, Cremillieux Y. Validation of simple and robust protocols for high-resolution lung proton MRI in mice. Magn Reson Med 2010;64:401-407.
    • (2010) Magn Reson Med , vol.64 , pp. 401-407
    • Zurek, M.1    Bessaad, A.2    Cieslar, K.3    Cremillieux, Y.4
  • 6
    • 78649656063 scopus 로고    scopus 로고
    • Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: Review of current and emerging translational methods and applications
    • Fain S, Schiebler ML, McCormack DG, Parraga G. Imaging of lung function using hyperpolarized helium-3 magnetic resonance imaging: review of current and emerging translational methods and applications. J Magn Reson Imaging 2010;32:1398-1408.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 1398-1408
    • Fain, S.1    Schiebler, M.L.2    McCormack, D.G.3    Parraga, G.4
  • 7
    • 0029760132 scopus 로고    scopus 로고
    • Pulmonary perfusion: Qualitative assessment with dynamic contrastenhanced MRI using ultra-short TE and inversion recovery turbo FLASH
    • Hatabu H, Gaa J, Kim D, Li W, Prasad P V, Edelman RR. Pulmonary perfusion: qualitative assessment with dynamic contrastenhanced MRI using ultra-short TE and inversion recovery turbo FLASH. Magn Reson Med 1996;36:503-508.
    • (1996) Magn Reson Med , vol.36 , pp. 503-508
    • Hatabu, H.1    Gaa, J.2    Kim, D.3    Li, W.4    Prasad, P.V.5    Edelman, R.R.6
  • 8
    • 4344601293 scopus 로고    scopus 로고
    • Quantitative assessment of regional pulmonary perfusion in the entire lung using threedimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects
    • Ohno Y, Hatabu H, Murase K, et al. Quantitative assessment of regional pulmonary perfusion in the entire lung using threedimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects. J Magn Reson Imaging 2004;20:353-365.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 353-365
    • Ohno, Y.1    Hatabu, H.2    Murase, K.3
  • 10
    • 0030770299 scopus 로고    scopus 로고
    • Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    • Wilman A, Riederer S, King B, et al. Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries. Radiology 1997;205:137-146.
    • (1997) Radiology , vol.205 , pp. 137-146
    • Wilman, A.1    Riederer, S.2    King, B.3
  • 12
    • 1642353675 scopus 로고    scopus 로고
    • Regional lung perfusion: Assessment with partially parallel three-dimensional MR imaging
    • Fink C, Puderbach M, Bock M, et al. Regional lung perfusion: assessment with partially parallel three-dimensional MR imaging. Radiology 2004;231:175-184.
    • (2004) Radiology , vol.231 , pp. 175-184
    • Fink, C.1    Puderbach, M.2    Bock, M.3
  • 13
    • 4143052375 scopus 로고    scopus 로고
    • Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique
    • Nikolaou K, Schoenberg SO, Brix G, et al. Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique. Invest Radiol 2004;39:537-545.
    • (2004) Invest Radiol , vol.39 , pp. 537-545
    • Nikolaou, K.1    Schoenberg, S.O.2    Brix, G.3
  • 14
    • 84883423833 scopus 로고    scopus 로고
    • Pulmonary perfusion MRI using interleaved variable density sampling and HighlY constrained cartesian reconstruction (HYCR)
    • Wang K, Schiebler ML, Francois CJ, et al. Pulmonary perfusion MRI using interleaved variable density sampling and HighlY constrained cartesian reconstruction (HYCR). J Magn Reson Imaging 2013;38:751-756.
    • (2013) J Magn Reson Imaging , vol.38 , pp. 751-756
    • Wang, K.1    Schiebler, M.L.2    Francois, C.J.3
  • 15
    • 0033984786 scopus 로고    scopus 로고
    • Undersampled projection-reconstruction imaging for time-resolved contrast- enhanced imaging
    • Vigen KK, Peters DC, Grist TM, Block WF, Mistretta CA. Undersampled projection-reconstruction imaging for time-resolved contrast- enhanced imaging. Magn Reson Med 2000;43:170-176.
    • (2000) Magn Reson Med , vol.43 , pp. 170-176
    • Vigen, K.K.1    Peters, D.C.2    Grist, T.M.3    Block, W.F.4    Mistretta, C.A.5
  • 16
    • 0033971791 scopus 로고    scopus 로고
    • Undersampled projection reconstruction applied to MR angiography
    • Peters DC, Korosec FR, Grist TM, et al. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 2000;43:91-101.
    • (2000) Magn Reson Med , vol.43 , pp. 91-101
    • Peters, D.C.1    Korosec, F.R.2    Grist, T.M.3
  • 17
    • 0036319895 scopus 로고    scopus 로고
    • Timeresolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
    • Barger A V, Block WF, Toropov Y, Grist TM, Mistretta CA. Timeresolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002;48:297-305.
    • (2002) Magn Reson Med , vol.48 , pp. 297-305
    • Barger, A.V.1    Block, W.F.2    Toropov, Y.3    Grist, T.M.4    Mistretta, C.A.5
  • 19
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 21
    • 0030183445 scopus 로고    scopus 로고
    • The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality
    • Maki JH, Prince MR, Londy FJ, Chenevert TL. The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality. J Magn Reson Imaging 6:642-651.
    • J Magn Reson Imaging , vol.6 , pp. 642-651
    • Maki, J.H.1    Prince, M.R.2    Londy, F.J.3    Chenevert, T.L.4
  • 22
    • 0036199278 scopus 로고    scopus 로고
    • Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilationperfusion scintigraphy: An intra-modality and inter-modality agreement study
    • Amundsen T, Torheim G, Kvistad KA, et al. Perfusion abnormalities in pulmonary embolism studied with perfusion MRI and ventilationperfusion scintigraphy: an intra-modality and inter-modality agreement study. J Magn Reson Imaging 2002;15:386-94.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 386-394
    • Amundsen, T.1    Torheim, G.2    Kvistad, K.A.3
  • 24
    • 80051944922 scopus 로고    scopus 로고
    • Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism
    • Togao O, Ohno Y, Dimitrov I, Hsia CC, Takahashi M. Ventilation/perfusion imaging of the lung using ultra-short echo time (UTE) MRI in an animal model of pulmonary embolism. J Magn Reson Imaging 2011;34:539-546.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 539-546
    • Togao, O.1    Ohno, Y.2    Dimitrov, I.3    Hsia, C.C.4    Takahashi, M.5
  • 25
    • 0036872779 scopus 로고    scopus 로고
    • Topographical distribution of pulmonary perfusion and ventilation, assessed by PET in supine and prone humans
    • Musch G, Layfield JDH, Harris RS, et al. Topographical distribution of pulmonary perfusion and ventilation, assessed by PET in supine and prone humans. J Appl Physiol (1985) 2002;93:1841-1851.
    • (2002) J Appl Physiol (1985) , vol.93 , pp. 1841-1851
    • Musch, G.1    Layfield, J.D.H.2    Harris, R.S.3
  • 26
    • 0002537620 scopus 로고
    • Regional distribution of pulmonary ventilation and perfusion in elderly subjects
    • Holland J, Milic-Emili J, Macklem PT, Bates DV. Regional distribution of pulmonary ventilation and perfusion in elderly subjects. J Clin Invest 1968;47:81-92.
    • (1968) J Clin Invest , vol.47 , pp. 81-92
    • Holland, J.1    Milic-Emili, J.2    Macklem, P.T.3    Bates, D.V.4
  • 27
    • 84860751918 scopus 로고    scopus 로고
    • Morphologic and functional scoring of cystic fibrosis lung disease using MRI
    • Eichinger M, Optazaite D-E, Kopp-Schneider A, et al. Morphologic and functional scoring of cystic fibrosis lung disease using MRI. Eur J Radiol 2012;81:1321-1329.
    • (2012) Eur J Radiol , vol.81 , pp. 1321-1329
    • Eichinger, M.1    Optazaite, D.-E.2    Kopp-Schneider, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.