메뉴 건너뛰기




Volumn 134, Issue , 2014, Pages 499-505

Quantitative infrared thermography imaging of the density of heat flow rate through a building element surface

Author keywords

Density of heat flow rate; Infrared thermography; Measurement uncertainty; Thermal transmittance

Indexed keywords

ATMOSPHERIC TEMPERATURE; BUILDING COMPONENTS; FLOW MEASURING INSTRUMENTS; FLOW RATE; HEAT CONVECTION; HEAT TRANSFER COEFFICIENTS; MEASUREMENT ERRORS; SURFACE PROPERTIES; THERMAL INSULATION; UNCERTAINTY ANALYSIS; WIND;

EID: 84918829189     PISSN: 03062619     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apenergy.2014.08.058     Document Type: Article
Times cited : (50)

References (27)
  • 1
    • 84918822612 scopus 로고
    • ISO 9869. Thermal insulation - Building elements - In-situ measurement of thermal resistance and thermal transmittance
    • ISO 9869. Thermal insulation - Building elements - In-situ measurement of thermal resistance and thermal transmittance; 1994.
    • (1994)
  • 2
    • 0022563645 scopus 로고
    • Measurement errors with surface-mounted heat flux sensors
    • Trethowen H. Measurement errors with surface-mounted heat flux sensors. Build Environ 1986, 21:41-56.
    • (1986) Build Environ , vol.21 , pp. 41-56
    • Trethowen, H.1
  • 4
    • 0031641004 scopus 로고    scopus 로고
    • Assessing the thermal insulation of old buildings - the need for in situ spot measurements of thermal resistance and planar infrared thermography
    • Haralambopoulos D.A., Paparsenos G.F. Assessing the thermal insulation of old buildings - the need for in situ spot measurements of thermal resistance and planar infrared thermography. Energy Convers Manage 1998, 39:65-79.
    • (1998) Energy Convers Manage , vol.39 , pp. 65-79
    • Haralambopoulos, D.A.1    Paparsenos, G.F.2
  • 5
    • 70450199111 scopus 로고    scopus 로고
    • Evaluating the thermal resistance of building structures by using infrared thermography under transient conditions
    • Vavilov V.P., Marinetti S., Nesteruk D.A. Evaluating the thermal resistance of building structures by using infrared thermography under transient conditions. Russian J Nondestruct Test 2009, 45:481-490.
    • (2009) Russian J Nondestruct Test , vol.45 , pp. 481-490
    • Vavilov, V.P.1    Marinetti, S.2    Nesteruk, D.A.3
  • 6
    • 83355161527 scopus 로고    scopus 로고
    • How accurate is the IR thermographic evaluation of heat losses from buildings?
    • Vavilov V.P. How accurate is the IR thermographic evaluation of heat losses from buildings?. QIRT J 2010, 7:255-258.
    • (2010) QIRT J , vol.7 , pp. 255-258
    • Vavilov, V.P.1
  • 7
    • 77956174538 scopus 로고    scopus 로고
    • Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site
    • Albatici R., Tonelli A.M. Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site. Energy Build 2010, 42:2177-2183.
    • (2010) Energy Build , vol.42 , pp. 2177-2183
    • Albatici, R.1    Tonelli, A.M.2
  • 8
    • 80052260341 scopus 로고    scopus 로고
    • Application of infrared thermography for the determination of the overall heat transfer coefficient (U-value) in building envelopes
    • Fokaides P.A., Kalogirou S.A. Application of infrared thermography for the determination of the overall heat transfer coefficient (U-value) in building envelopes. Appl Energy 2011, 88:4358-4365.
    • (2011) Appl Energy , vol.88 , pp. 4358-4365
    • Fokaides, P.A.1    Kalogirou, S.A.2
  • 9
    • 82455166929 scopus 로고    scopus 로고
    • Vorschlag zur standardisierten Darstellung von Wärmebildern mit QualiThermo
    • Tanner C., Lehmann B., Frank T., Ghazi Wakili K. Vorschlag zur standardisierten Darstellung von Wärmebildern mit QualiThermo. Bauphysik 2011, 33:345-356.
    • (2011) Bauphysik , vol.33 , pp. 345-356
    • Tanner, C.1    Lehmann, B.2    Frank, T.3    Ghazi Wakili, K.4
  • 10
    • 84860808431 scopus 로고    scopus 로고
    • Experimental analysis of the infrared thermography for the thermal characterization of a building envelope
    • Ferreira G., Aranda A., Mainar-Toledo M.D., Zambrana D. Experimental analysis of the infrared thermography for the thermal characterization of a building envelope. Defect Diffus Forum 2012, 326-328:318-323.
    • (2012) Defect Diffus Forum , pp. 318-323
    • Ferreira, G.1    Aranda, A.2    Mainar-Toledo, M.D.3    Zambrana, D.4
  • 11
    • 84862309498 scopus 로고    scopus 로고
    • A quantitative methodology to evaluate thermal bridges in buildings
    • Asdrubali F., Baldinelli G., Bianchi F. A quantitative methodology to evaluate thermal bridges in buildings. Appl Energy 2012, 97:365-373.
    • (2012) Appl Energy , vol.97 , pp. 365-373
    • Asdrubali, F.1    Baldinelli, G.2    Bianchi, F.3
  • 13
    • 79954484200 scopus 로고    scopus 로고
    • The most problematic variable in the course of human-biometeorological comfort assessment - the mean radiant temperature
    • Kántor N., Unger J. The most problematic variable in the course of human-biometeorological comfort assessment - the mean radiant temperature. Cent Eur J Geosci 2011, 3:90-100.
    • (2011) Cent Eur J Geosci , vol.3 , pp. 90-100
    • Kántor, N.1    Unger, J.2
  • 14
    • 84876521362 scopus 로고    scopus 로고
    • Review of external convective heat transfer coefficient models in building energy simulation programs: Implementation and uncertainty
    • Mirsadeghi M., Cóstola D., Blocken B., Hensen J.L.M. Review of external convective heat transfer coefficient models in building energy simulation programs: Implementation and uncertainty. Appl Therm Eng 2013, 56:134-151.
    • (2013) Appl Therm Eng , vol.56 , pp. 134-151
    • Mirsadeghi, M.1    Cóstola, D.2    Blocken, B.3    Hensen, J.L.M.4
  • 15
    • 79955024867 scopus 로고    scopus 로고
    • Convective heat transfer coefficients for exterior building surfaces: existing correlations and CFD modelling
    • Defraeye T., Blocken B., Carmeliet J. Convective heat transfer coefficients for exterior building surfaces: existing correlations and CFD modelling. Energy Convers Manage 2011, 52:512-522.
    • (2011) Energy Convers Manage , vol.52 , pp. 512-522
    • Defraeye, T.1    Blocken, B.2    Carmeliet, J.3
  • 16
    • 40049105510 scopus 로고    scopus 로고
    • A survey of wind convection coefficient correlations for building envelope energy systems' modeling
    • Palyvos J.A. A survey of wind convection coefficient correlations for building envelope energy systems' modeling. Appl Therm Eng 2008, 28:801-808.
    • (2008) Appl Therm Eng , vol.28 , pp. 801-808
    • Palyvos, J.A.1
  • 17
    • 60249093331 scopus 로고    scopus 로고
    • Der wärmeübergang an einer ebenen wand (heat transfer at a plane wall)
    • Gesundheits-Ingenieur; 1924. Beiheft nr 19.
    • Jürges W. Der wärmeübergang an einer ebenen wand (heat transfer at a plane wall). Gesundheits-Ingenieur; 1924. Beiheft nr 19.
    • Jürges, W.1
  • 18
    • 85021190122 scopus 로고    scopus 로고
    • JCGM 100 Evaluation of measurement data - guide to the expression of uncertainty in measurement (GUM 1995 with minor correction) 2008, BIPM, Geneva.
    • (2008)
  • 20
    • 0028255074 scopus 로고
    • Method and apparatus for determination of the total directional emissivity of opaque materials in the temperature range 300-600K
    • Cheng S.X., Jing S.X., Ge X.S., Yao C.C. Method and apparatus for determination of the total directional emissivity of opaque materials in the temperature range 300-600K. Int J Thermophys 1994, 15:177-187.
    • (1994) Int J Thermophys , vol.15 , pp. 177-187
    • Cheng, S.X.1    Jing, S.X.2    Ge, X.S.3    Yao, C.C.4
  • 21
    • 20144369897 scopus 로고    scopus 로고
    • Improvement of building wall surface temperature measurements by infrared thermography
    • Datcu S., Ibos L., Candau Y., Matteï S. Improvement of building wall surface temperature measurements by infrared thermography. Infrared Phys Technol 2005, 46:451-467.
    • (2005) Infrared Phys Technol , vol.46 , pp. 451-467
    • Datcu, S.1    Ibos, L.2    Candau, Y.3    Matteï, S.4
  • 22
    • 3342897002 scopus 로고
    • Evaluation of the quality of a blackbody
    • De Vos J.C. Evaluation of the quality of a blackbody. Physica 1954, 20:669-689.
    • (1954) Physica , vol.20 , pp. 669-689
    • De Vos, J.C.1
  • 23
    • 84918773702 scopus 로고
    • ISO 8302, Thermal insulation. Determination of steady-state thermal resistance and related properties. Guarded hot plate apparatus
    • ISO 8302. Thermal insulation. Determination of steady-state thermal resistance and related properties. Guarded hot plate apparatus; 1991.
    • (1991)
  • 24
    • 79960566372 scopus 로고    scopus 로고
    • Uncertainty functions, a compact way of summarising or specifying the behaviour of analytical systems
    • Thompson M. Uncertainty functions, a compact way of summarising or specifying the behaviour of analytical systems. Trends Anal Chem 2011, 30:1168-1175.
    • (2011) Trends Anal Chem , vol.30 , pp. 1168-1175
    • Thompson, M.1
  • 25
    • 84864506850 scopus 로고    scopus 로고
    • Emissivity estimation for accurate quantitative thermography
    • Marinetti S., Cesaratto P.G. Emissivity estimation for accurate quantitative thermography. NDT&E Int 2012, 51:127-134.
    • (2012) NDT&E Int , vol.51 , pp. 127-134
    • Marinetti, S.1    Cesaratto, P.G.2
  • 26
    • 84881496363 scopus 로고    scopus 로고
    • Assessment of the thermal emissivity value of building materials using an infrared thermovision technique emissometer
    • Albatici R., Passerini F., Tonelli A.M., Gialanella S. Assessment of the thermal emissivity value of building materials using an infrared thermovision technique emissometer. Energy Build 2013, 66:33-40.
    • (2013) Energy Build , vol.66 , pp. 33-40
    • Albatici, R.1    Passerini, F.2    Tonelli, A.M.3    Gialanella, S.4
  • 27
    • 33847037160 scopus 로고    scopus 로고
    • Full-scale measurements of convective coefficient on external surface of a low-rise building in sheltered conditions
    • Liu Y., Harris D.J. Full-scale measurements of convective coefficient on external surface of a low-rise building in sheltered conditions. Build Environ 2007, 42:2718-2736.
    • (2007) Build Environ , vol.42 , pp. 2718-2736
    • Liu, Y.1    Harris, D.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.