메뉴 건너뛰기




Volumn 23, Issue 9, 2014, Pages 649-652

Using a collagen matrix implant (Ologen) versus mitomycin-C as a wound healing modulator in trabeculectomy with the Ex-PRESS mini glaucoma device: A 12-month retrospective review

Author keywords

Adjuvants in trabeculectomy; Mitomycin C; Ologen; Trabeculectomy

Indexed keywords

DEXAMETHASONE; MITOMYCIN; NEOMYCIN; POLYMYXIN B; PREDNISOLONE ACETATE; ALKYLATING AGENT; COLLAGEN; COLLAGEN-GLYCOSAMINOGLYCAN COPOLYMER; GLYCOSAMINOGLYCAN;

EID: 84918781098     PISSN: 10570829     EISSN: 1536481X     Source Type: Journal    
DOI: 10.1097/IJG.0000000000000018     Document Type: Article
Times cited : (29)

References (13)
  • 1
    • 57149121531 scopus 로고    scopus 로고
    • Nine-year follow-up of trabeculectomy with or without low-dosage mitomycin-c in primary open-angle glaucoma
    • Reibaldi A, Uva MG, Longo A. Nine-year follow-up of trabeculectomy with or without low-dosage mitomycin-c in primary open-angle glaucoma. Br J Ophthalmol. 2008;92: 1666-1670.
    • (2008) Br J Ophthalmol , vol.92 , pp. 1666-1670
    • Reibaldi, A.1    Uva, M.G.2    Longo, A.3
  • 3
    • 0027724346 scopus 로고
    • Histopathology of an avascular filtering bleb after trabeculectomy with mitomycin-C
    • Mietz H, Brunner R, Addicks K, et al. Histopathology of an avascular filtering bleb after trabeculectomy with mitomycin-C. J Glaucoma. 1993;2:2266-2270.
    • (1993) J Glaucoma , vol.2 , pp. 2266-2270
    • Mietz, H.1    Brunner, R.2    Addicks, K.3
  • 4
    • 0036127424 scopus 로고    scopus 로고
    • Incidence of lateonset bleb-related complications following trabeculectomy with mitomycin
    • Debry PW, Perkins TW, Heatly G, et al. Incidence of lateonset bleb-related complications following trabeculectomy with mitomycin. Arch Ophthalmol. 2002;120:297-300.
    • (2002) Arch Ophthalmol , vol.120 , pp. 297-300
    • Debry, P.W.1    Perkins, T.W.2    Heatly, G.3
  • 5
    • 0031916590 scopus 로고    scopus 로고
    • Late-onset bleb leaks after glaucoma filtering surgery
    • Greenfield DS, Liebmann JM, Jee J, et al. Late-onset bleb leaks after glaucoma filtering surgery. Arch Ophthalmol. 1998; 116:443-447.
    • (1998) Arch Ophthalmol , vol.116 , pp. 443-447
    • Greenfield, D.S.1    Liebmann, J.M.2    Jee, J.3
  • 6
    • 84859270329 scopus 로고    scopus 로고
    • Outcomes and blebrelated complications of trabeculectomy
    • Jampel HD, Solus JF, Tracey PA, et al. Outcomes and blebrelated complications of trabeculectomy. Ophthalmology. 2012; 119:712-722.
    • (2012) Ophthalmology , vol.119 , pp. 712-722
    • Jampel, H.D.1    Solus, J.F.2    Tracey, P.A.3
  • 7
    • 34248150374 scopus 로고    scopus 로고
    • Control of filtering belb structure through tissue bioengineering: An animal model
    • Chen HS, Ritch R, Krupin T, et al. Control of filtering belb structure through tissue bioengineering: an animal model. Invest Ophthalmol Vis Sci. 2006;47:5310-5314.
    • (2006) Invest Ophthalmol Vis Sci. , vol.47 , pp. 5310-5314
    • Chen, H.S.1    Ritch, R.2    Krupin, T.3
  • 8
    • 42049103238 scopus 로고    scopus 로고
    • Tissue bioengineering for surgical bleb defects: An animal study
    • Hsu WC, Ritch R, Krupin T, et al. Tissue bioengineering for surgical bleb defects: an animal study. Graefes Arch Clin Exp Ophthalmol. 2008;246:709-717.
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 709-717
    • Hsu, W.C.1    Ritch, R.2    Krupin, T.3
  • 9
    • 77956565354 scopus 로고    scopus 로고
    • A prospective randomized trial of trabeculectomy using mitomycin C vs an ologen implant in open angle glaucoma
    • Rosentreter A, Schild AM, Jordan JF, et al. A prospective randomized trial of trabeculectomy using mitomycin C vs an ologen implant in open angle glaucoma. Eye. 2010;24: 1449-1457.
    • (2010) Eye , vol.24 , pp. 1449-1457
    • Rosentreter, A.1    Schild, A.M.2    Jordan, J.F.3
  • 10
    • 79952034255 scopus 로고    scopus 로고
    • Imaging of blebs after phacotrabeculectomy with Ologen collagen matrix implants
    • Boey PY, Narayanaswamy A, Aheng C, et al. Imaging of blebs after phacotrabeculectomy with Ologen collagen matrix implants. Br J Ophthalmol. 2011;95:340-344.
    • (2011) Br J Ophthalmol , vol.95 , pp. 340-344
    • Boey, P.Y.1    Narayanaswamy, A.2    Aheng, C.3
  • 11
    • 76149121451 scopus 로고    scopus 로고
    • Trabeculectomy with OloGen vs trabeculectomy for the treatment of glaucoma: A pilot study
    • Papaconstantinou D, Georgalas I, Karmiris E, et al. Trabeculectomy with OloGen vs trabeculectomy for the treatment of glaucoma: a pilot study. Acta Ophthalmol. 2010;88:80-85.
    • (2010) Acta Ophthalmol , vol.88 , pp. 80-85
    • Papaconstantinou, D.1    Georgalas, I.2    Karmiris, E.3
  • 12
    • 83455186692 scopus 로고    scopus 로고
    • Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: A 24-month, randomized clinical trial
    • Cillino S, Di Pace F, Cillino G, et al. Biodegradable collagen matrix implant vs mitomycin-C as an adjuvant in trabeculectomy: a 24-month, randomized clinical trial. Eye. 2011;25: 1598-1606.
    • (2011) Eye , vol.25 , pp. 1598-1606
    • Cillino, S.1    Di Pace, F.2    Cillino, G.3
  • 13
    • 33846310799 scopus 로고    scopus 로고
    • Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under sclera flap
    • Maris PJ, Ishida K, Netland PA. Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under sclera flap. J Glaucoma. 2007;16:14-19.
    • (2007) J Glaucoma , vol.16 , pp. 14-19
    • Maris, P.J.1    Ishida, K.2    Netland, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.