메뉴 건너뛰기




Volumn 9, Issue 4, 2014, Pages 469-472

Predictive value of one-dimensional mean computed tomography value of ground-glass opacity on high-resolution images for the possibility of future change

Author keywords

Ground glass opacity; Mean computed tomography; Radiological features

Indexed keywords

ADULT; AGED; ARTICLE; CANCER PATIENT; CANCER SURGERY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER GRAPHICS; FEMALE; FOLLOW UP; GROUND GLASS OPACITY; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; LUNG CANCER; MAJOR CLINICAL STUDY; MALE; MEDICAL HISTORY; MEDICAL RECORD; PREDICTION; PREDICTIVE VALUE; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; RETROSPECTIVE STUDY; RISK FACTOR; SMOKING HABIT; ADENOCARCINOMA; CANCER STAGING; COMPUTER ASSISTED TOMOGRAPHY; DISEASE COURSE; LUNG TUMOR; MIDDLE AGED; PATHOLOGY; PROCEDURES; PROGNOSIS; RADIOGRAPHY; VERY ELDERLY;

EID: 84918542663     PISSN: 15560864     EISSN: 15561380     Source Type: Journal    
DOI: 10.1097/JTO.0000000000000117     Document Type: Article
Times cited : (65)

References (18)
  • 1
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • Sone S, Takashima S, Li F, et al. Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 1998;351:1242-1245.
    • (1998) Lancet , vol.351 , pp. 1242-1245
    • Sone, S.1    Takashima, S.2    Li, F.3
  • 2
    • 0037083316 scopus 로고    scopus 로고
    • Screening for lung cancer with low-dose helical computed tomography: Anti-lung cancer association project
    • Sobue T, Moriyama N, Kaneko M, et al. Screening for lung cancer with low-dose helical computed tomography: anti-lung cancer association project. J Clin Oncol 2002;20:911-920.
    • (2002) J Clin Oncol , vol.20 , pp. 911-920
    • Sobue, T.1    Moriyama, N.2    Kaneko, M.3
  • 3
    • 34247233915 scopus 로고    scopus 로고
    • Nodular ground-glass opacity at tinsection CT: Histologic correlation and evaluation of change at follow-up
    • Park CM, Goo JM, Lee HJ, et al. Nodular ground-glass opacity at tinsection CT: histologic correlation and evaluation of change at follow-up. Radiographics 2007; 27: 391-408.
    • (2007) Radiographics , vol.27 , pp. 391-408
    • Park, C.M.1    Goo, J.M.2    Lee, H.J.3
  • 4
    • 84988483285 scopus 로고    scopus 로고
    • Follow up and screening guideline for lung cancer CT examination
    • Accessed on
    • Follow up and screening guideline for lung cancer CT examination. JSCTS. Available at: http:// www.thoracic-CT-screening.org/jpn/index.html. Accessed on
    • JSCTS
  • 5
    • 79551563284 scopus 로고    scopus 로고
    • International association for the study of lung cancer/American thoracic society/european respiratory society international multidisciplinary classification of lung adenocarcinoma
    • Travis WD, Brambilla E, Noguchi M, et al. International association for the study of lung cancer/american thoracic society/european respiratory society international multidisciplinary classification of lung adenocarcinoma. J Thorac Oncol 2011;6:244-285.
    • (2011) J Thorac Oncol , vol.6 , pp. 244-285
    • Travis, W.D.1    Brambilla, E.2    Noguchi, M.3
  • 6
    • 77649171391 scopus 로고    scopus 로고
    • Management of multiple pure ground-glass opacity lesions in patients with bronchioloalveolar carcinoma
    • Kim HK, Choi YS, Kim J, Shim YM, Lee KS, Kim K. Management of multiple pure ground-glass opacity lesions in patients with bronchioloalveolar carcinoma. J Thorac Oncol 2010;5:206-210.
    • (2010) J Thorac Oncol , vol.5 , pp. 206-210
    • Kim, H.K.1    Choi, Y.S.2    Kim, J.3    Shim, Y.M.4    Lee, K.S.5    Kim, K.6
  • 7
    • 34548672818 scopus 로고    scopus 로고
    • Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons
    • Kim HY, Shim YM, Lee KS, Han J, Yi CA, Kim YK. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Radiology 2007;245:267-275.
    • (2007) Radiology , vol.245 , pp. 267-275
    • Kim, H.Y.1    Shim, Y.M.2    Lee, K.S.3    Han, J.4    Yi, C.A.5    Kim, Y.K.6
  • 8
    • 33846899417 scopus 로고    scopus 로고
    • Nodular ground-glass opacities on thin-section CT: Size change during follow-up and pathological results
    • Lee HJ, Goo JM, Lee CH, Yoo CG, Kim YT, Im JG. Nodular ground-glass opacities on thin-section CT: size change during follow-up and pathological results. Korean J Radiol 2007;8:22-31.
    • (2007) Korean J Radiol , vol.8 , pp. 22-31
    • Lee, H.J.1    Goo, J.M.2    Lee, C.H.3    Yoo, C.G.4    Kim, Y.T.5    Im, J.G.6
  • 9
    • 84858003365 scopus 로고    scopus 로고
    • Ground-glass opacity lesions on computed tomography during postoperative surveillance for primary non-small cell lung cancer
    • Haro A, Yano T, Kohno M, Yoshida T, Okamoto T, Maehara Y. Ground-glass opacity lesions on computed tomography during postoperative surveillance for primary non-small cell lung cancer. Lung Cancer 2012;76:56-60.
    • (2012) Lung Cancer , vol.76 , pp. 56-60
    • Haro, A.1    Yano, T.2    Kohno, M.3    Yoshida, T.4    Okamoto, T.5    Maehara, Y.6
  • 11
    • 0034986647 scopus 로고    scopus 로고
    • High-resolution CT analysis of small peripheral lung adenocarcinomas revealed on screening helical CT
    • Yang ZG, Sone S, Takashima S, et al. High-resolution CT analysis of small peripheral lung adenocarcinomas revealed on screening helical CT. AJR Am J Roentgenol 2001;176:1399-1407.
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 1399-1407
    • Yang, Z.G.1    Sone, S.2    Takashima, S.3
  • 12
    • 0025822337 scopus 로고
    • Prevalence of air bronchograms in small peripheral carcinomas of the lung on thin-section CT
    • Kuriyama K, Tateishi R, Doi O, et al. Prevalence of air bronchograms in small peripheral carcinomas of the lung on thin-section CT. Am J Roentgenol 1991; 156: 921-924.
    • (1991) Am J Roentgenol , vol.156 , pp. 921-924
    • Kuriyama, K.1    Tateishi, R.2    Doi, O.3
  • 13
    • 0027446637 scopus 로고
    • Focal organizing pneumonia: CT appearance
    • Kohno N, Ikezoe J, Johkoh T, et al. Focal organizing pneumonia: CT appearance. Radiology 1993;189:119-123.
    • (1993) Radiology , vol.189 , pp. 119-123
    • Kohno, N.1    Ikezoe, J.2    Johkoh, T.3
  • 14
    • 0036251768 scopus 로고    scopus 로고
    • Focal ground-glass opacity detected by low-dose helical CT
    • Nakata M, Saeki H, Takata I, et al. Focal ground-glass opacity detected by low-dose helical CT. Chest 2002;121:1464-1467.
    • (2002) Chest , vol.121 , pp. 1464-1467
    • Nakata, M.1    Saeki, H.2    Takata, I.3
  • 15
    • 84874046756 scopus 로고    scopus 로고
    • Characteristics of subsolid pulmonary nodules showing growth during follow-up with CT scanning
    • Matsuguma H, Mori K, Nakahara R, et al. Characteristics of subsolid pulmonary nodules showing growth during follow-up with CT scanning. Chest 2013;143:436-443.
    • (2013) Chest , vol.143 , pp. 436-443
    • Matsuguma, H.1    Mori, K.2    Nakahara, R.3
  • 16
    • 35449003214 scopus 로고    scopus 로고
    • Differential diagnosis of ground-glass opacity nodules. Ct number analysis by three dimensional computerized quantification
    • Ikeda K, Awai K, Mori T, et al. Differential diagnosis of ground-glass opacity nodules. Ct number analysis by three dimensional computerized quantification. Chest 2007; 132: 984-990.
    • (2007) Chest , vol.132 , pp. 984-990
    • Ikeda, K.1    Awai, K.2    Mori, T.3
  • 17
    • 0041329981 scopus 로고    scopus 로고
    • Differentiating between atypical adenomatous hyperplasia and bronchioloalveolar carcinoma using the computed tomography number histogram
    • Nomori H, Ohtsuka T, Naruke T, Suemasu K. Differentiating between atypical adenomatous hyperplasia and bronchioloalveolar carcinoma using the computed tomography number histogram. Ann Thorac Surg 2003;76:867-871.
    • (2003) Ann Thorac Surg , vol.76 , pp. 867-871
    • Nomori, H.1    Ohtsuka, T.2    Naruke, T.3    Suemasu, K.4
  • 18
    • 67649782358 scopus 로고    scopus 로고
    • One-dimensional quantitative evaluation of peripheral lung adenocarcinoma with or without ground-glass opacity on thin-section CT images using profile curves
    • Yanagawa M, Kuriyama K, Kunitomi Y, et al. One-dimensional quantitative evaluation of peripheral lung adenocarcinoma with or without ground-glass opacity on thin-section CT images using profile curves. Br J Radiol 2009;82:532-540.
    • (2009) Br J Radiol , vol.82 , pp. 532-540
    • Yanagawa, M.1    Kuriyama, K.2    Kunitomi, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.