메뉴 건너뛰기




Volumn 23, Issue 8, 2014, Pages e138-e143

Comparison of fluctuations of intraocular pressure before and after selective laser trabeculoplasty in normal-tension glaucoma patients

Author keywords

Contact lens sensor; Intraocular pressure (IOP); Nocturnal fluctuation; Normal tension glaucoma (NTG); Selective laser trabeculoplasty (SLT)

Indexed keywords

ACETAZOLAMIDE; APRACLONIDINE; EYE DROPS;

EID: 84916597457     PISSN: 10570829     EISSN: 1536481X     Source Type: Journal    
DOI: 10.1097/IJG.0000000000000026     Document Type: Article
Times cited : (55)

References (16)
  • 1
    • 0025838179 scopus 로고
    • Epidemiology of glaucoma in Japan-A nationwide glaucoma survey
    • Shiose Y, Kitazawa Y, Tsukahara S, et al. Epidemiology of glaucoma in Japan-A nationwide glaucoma survey. Jpn J Ophthalmol. 1991;35: 133-155.
    • (1991) Jpn J Ophthalmol. , vol.35 , pp. 133-155
    • Shiose, Y.1    Kitazawa, Y.2    Tsukahara, S.3
  • 2
    • 25844457745 scopus 로고    scopus 로고
    • The Tajimi Study report 2: Prevalence of primary angle closure and secondary glaucoma in a Japanese population
    • Yamamoto T, Iwase A, Araie M, et al. The Tajimi Study report 2: Prevalence of primary angle closure and secondary glaucoma in a Japanese population. Ophthalmology. 2005; 112: 1661-1669.
    • (2005) Ophthalmology. , vol.112 , pp. 1661-1669
    • Yamamoto, T.1    Iwase, A.2    Araie, M.3
  • 3
    • 81155134853 scopus 로고    scopus 로고
    • Risk factors for primary open-Angle glaucoma in Japanese subjects attending community health screenings
    • Ishikawa M, Sawada Y, Sato N, et al. Risk factors for primary open-Angle glaucoma in Japanese subjects attending community health screenings. Clin Ophthalmol. 2011;5: 1531-1537.
    • (2011) Clin Ophthalmol. , vol.5 , pp. 1531-1537
    • Ishikawa, M.1    Sawada, Y.2    Sato, N.3
  • 4
    • 33747879306 scopus 로고    scopus 로고
    • Risk factors for open-Angle glaucoma in a Japanese population: The Tajimi Study
    • Suzuki Y, Iwase A, Araie M, et al. Risk factors for open-Angle glaucoma in a Japanese population: The Tajimi Study. Ophthalmology. 2006;113: 1613-1617.
    • (2006) Ophthalmology. , vol.113 , pp. 1613-1617
    • Suzuki, Y.1    Iwase, A.2    Araie, M.3
  • 5
    • 51149096957 scopus 로고    scopus 로고
    • Ocular and systemic factors related to intraocular pressure in Japanese adults: The Tajimi study
    • Kawase K, Tomidokoro A, Araie M, et al. Ocular and systemic factors related to intraocular pressure in Japanese adults: The Tajimi study. Br J Ophthalmol. 2008;92: 1175-1179.
    • (2008) Br J Ophthalmol. , vol.92 , pp. 1175-1179
    • Kawase, K.1    Tomidokoro, A.2    Araie, M.3
  • 6
    • 0034448216 scopus 로고    scopus 로고
    • Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma
    • Asrani S, Zeimer R, Wilensky J, et al. Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. J Glaucoma. 2000;9: 134-142.
    • (2000) J Glaucoma. , vol.9 , pp. 134-142
    • Asrani, S.1    Zeimer, R.2    Wilensky, J.3
  • 7
    • 36249018462 scopus 로고    scopus 로고
    • Association between intraocular pressure variation and glaucoma progression: Data from a United States chart review
    • Lee PP, Walt JW, Rosenblatt LC, et al. Association between intraocular pressure variation and glaucoma progression: Data from a United States chart review. Am J Ophthalmol. 2007; 144: 901-907.
    • (2007) Am J Ophthalmol. , vol.144 , pp. 901-907
    • Lee, P.P.1    Walt, J.W.2    Rosenblatt, L.C.3
  • 8
    • 77956112369 scopus 로고    scopus 로고
    • Twenty-four hour ocular perfusion pressure fluctuation and risk of normal-Tension glaucoma progression
    • Sung KR, Lee S, Park SB, et al. Twenty-four hour ocular perfusion pressure fluctuation and risk of normal-Tension glaucoma progression. Invest Ophthalmol Vis Sci. 2009;50: 5266-5274.
    • (2009) Invest Ophthalmol Vis Sci. , vol.50 , pp. 5266-5274
    • Sung, K.R.1    Lee, S.2    Park, S.B.3
  • 9
    • 84859997424 scopus 로고    scopus 로고
    • Circadian (24-hour) pattern of intraocular pressure and visual field damage in eyes with normal-Tension glaucoma
    • Lee YR, Kook MS, Joe SG, et al. Circadian (24-hour) pattern of intraocular pressure and visual field damage in eyes with normal-Tension glaucoma. Invest Ophthalmol Vis Sci. 2012; 53: 881-887.
    • (2012) Invest Ophthalmol Vis Sci. , vol.53 , pp. 881-887
    • Lee, Y.R.1    Kook, M.S.2    Joe, S.G.3
  • 10
    • 77956132786 scopus 로고    scopus 로고
    • Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients
    • El Mallah MK, Walsh MM, Stinnett SS, et al. Selective laser trabeculoplasty reduces mean IOP and IOP variation in normal tension glaucoma patients. Clin Ophthalmol. 2010;9: 889-893.
    • (2010) Clin Ophthalmol. , vol.9 , pp. 889-893
    • El Mallah, M.K.1    Walsh, M.M.2    Stinnett, S.S.3
  • 11
    • 77952601923 scopus 로고    scopus 로고
    • Influence of selective laser trabeculoplasty on 24-hour diurnal intraocular pressure fluctuation in primary open-Angle glaucoma: A pilot study
    • Kóthy P, Tóth M, Holló G. Influence of selective laser trabeculoplasty on 24-hour diurnal intraocular pressure fluctuation in primary open-Angle glaucoma: A pilot study. Ophthalmic Surg Lasers Imaging. 2010;41: 342-347.
    • (2010) Ophthalmic Surg Lasers Imaging. , vol.41 , pp. 342-347
    • Kóthy, P.1    Tóth, M.2    Holló, G.3
  • 12
    • 79955031844 scopus 로고    scopus 로고
    • Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: Initial clinical experience in patients with open angle glaucoma
    • Mansouri K, Shaarawy T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: Initial clinical experience in patients with open angle glaucoma. Br J Ophthalmol. 2011;95: 627-629.
    • (2011) Br J Ophthalmol. , vol.95 , pp. 627-629
    • Mansouri, K.1    Shaarawy, T.2
  • 13
    • 84855470169 scopus 로고    scopus 로고
    • Clinical results of selective laser trabeculoplasty in open-Angle glaucoma in Japanese eyes: Comparison of 180 degree with 360 degree SLT
    • Shibata M, Sugiyama T, Ishida O, et al. Clinical results of selective laser trabeculoplasty in open-Angle glaucoma in Japanese eyes: Comparison of 180 degree with 360 degree SLT. J Glaucoma. 2012;21: 17-21.
    • (2012) J Glaucoma. , vol.21 , pp. 17-21
    • Shibata, M.1    Sugiyama, T.2    Ishida, O.3
  • 14
    • 84856888767 scopus 로고    scopus 로고
    • Peak intraocular pressure and glaucomatous progression in primary open-Angle glaucoma
    • Konstas AG, Quaranta L, Mikropoulos DG, et al. Peak intraocular pressure and glaucomatous progression in primary open-Angle glaucoma. J Ocul Pharmacol Ther. 2012;28: 26-32.
    • (2012) J Ocul Pharmacol Ther. , vol.28 , pp. 26-32
    • Konstas, A.G.1    Quaranta, L.2    Mikropoulos, D.G.3
  • 15
    • 81255142806 scopus 로고    scopus 로고
    • Continuous IOP fluctuation recording in normal tension glaucoma patients
    • Pajic B, Pajic-Eggspuchler B, Haefliger I. Continuous IOP fluctuation recording in normal tension glaucoma patients. Curr Eye Res. 2011;36: 1129-1138.
    • (2011) Curr Eye Res. , vol.36 , pp. 1129-1138
    • Pajic, B.1    Pajic-Eggspuchler, B.2    Haefliger, I.3
  • 16
    • 84867750285 scopus 로고    scopus 로고
    • Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: Safety, tolerability, and reproducibility in patients with glaucoma
    • Mansouri K, Medeiros FA, Tafreshi A, et al. Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: Safety, tolerability, and reproducibility in patients with glaucoma. Arch Ophthalmol. 2012;13: 1-6.
    • (2012) Arch Ophthalmol. , vol.13 , pp. 1-6
    • Mansouri, K.1    Medeiros, F.A.2    Tafreshi, A.3