-
1
-
-
84866426598
-
Practical medical applications of quantitativeMR relaxometry
-
H. M. Cheng, N. Stikov, N. R. Ghugre, and G. A. Wright, "Practical medical applications of quantitativeMR relaxometry," J. Magn. Reson. Imag., vol. 36, pp. 805-824, 2012
-
(2012)
J. Magn. Reson. Imag
, vol.36
, pp. 805-824
-
-
Cheng, H.M.1
Stikov, N.2
Ghugre, N.R.3
Wright, G.A.4
-
2
-
-
70350751580
-
Model-based iterative reconstruction for radial fast spin-echo MRI
-
Nov
-
K. T. Block, M. Uecker, and J. Frahm, "Model-based iterative reconstruction for radial fast spin-echo MRI," IEEE Trans. Med. Imag., vol. 28, no. 11, pp. 1759-1769, Nov. 2009
-
(2009)
IEEE Trans. Med. Imag
, vol.28
, Issue.11
, pp. 1759-1769
-
-
Block, K.T.1
Uecker, M.2
Frahm, J.3
-
3
-
-
77957300989
-
Compressed sensing reconstruction for magnetic resonance parameter mapping
-
M. Doneva, P. Börnert, H. Eggers, C. Stehning, J. Sénégas, and A. Mertins, "Compressed sensing reconstruction for magnetic resonance parameter mapping," Magn. Reson. Med., vol. 64, pp. 1114-1120, 2010
-
(2010)
Magn. Reson. Med
, vol.64
, pp. 1114-1120
-
-
Doneva, M.1
Börnert, P.2
Eggers, H.3
Stehning, C.4
Sénégas, J.5
Mertins, A.6
-
4
-
-
79960611551
-
Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI
-
T. J. Sumpf, M. Uecker, S. Boretius, and J. Frahm, "Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI," J. Magn. Reson. Imag., vol. 34, pp. 420-428, 2011
-
(2011)
J. Magn. Reson. Imag
, vol.34
, pp. 420-428
-
-
Sumpf, T.J.1
Uecker, M.2
Boretius, S.3
Frahm, J.4
-
5
-
-
84859719425
-
T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing
-
C. Huang, C. G. Graff, E.W. Clarkson, A. Bilgin, andM. I. Altbach, "T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing," Magn. Reson. Med., vol. 67, pp. 1355-1366, 2012
-
(2012)
Magn. Reson. Med
, vol.67
, pp. 1355-1366
-
-
Huang, C.1
Graff, C.G.2
Clarkson, E.W.3
Bilgin, A.4
Altbach, M.I.5
-
6
-
-
0022555963
-
Errors in the measurements of T2 using multiple-echo MRI techniques 1 Effects of radiofrequency pulse imperfections
-
S. Majumdar, S. C. Orphanoudakis, A. Gmitro, M. Odonnell, and J. C. Gore, "Errors in the measurements of T2 using multiple-echo MRI techniques. 1. Effects of radiofrequency pulse imperfections," Magn. Reson. Med., vol. 3, pp. 397-417, 1986
-
(1986)
Magn. Reson. Med
, vol.3
, pp. 397-417
-
-
Majumdar, S.1
Orphanoudakis, S.C.2
Gmitro, A.3
Odonnell, M.4
Gore, J.C.5
-
7
-
-
0022930453
-
Errors in the measurements of T2 using multiple-echo MRI techniques 2 Effects of static-field inhomogeneity
-
S. Majumdar, S. C. Orphanoudakis, A. Gmitro, M. Odonnell, and J. C. Gore, "Errors in the measurements of T2 using multiple-echo MRI techniques. 2. Effects of static-field inhomogeneity," Magn. Reson. Med., vol. 3, pp. 562-574, 1986
-
(1986)
Magn. Reson. Med
, vol.3
, pp. 562-574
-
-
Majumdar, S.1
Orphanoudakis, S.C.2
Gmitro, A.3
Odonnell, M.4
Gore, J.C.5
-
8
-
-
0023164952
-
Errors in T2 estimation using multislice multiple-echo imaging
-
A. P. Crawley and R. M. Henkelman, "Errors in T2 estimation using multislice multiple-echo imaging," Magn. Reson. Med., vol. 4, pp. 34-47, 1987
-
(1987)
Magn. Reson. Med
, vol.4
, pp. 34-47
-
-
Crawley, A.P.1
Henkelman, R.M.2
-
9
-
-
0034956787
-
Spatial variation in cartilage T2 of the knee
-
H. E. Smith, T. J.Mosher, B. J. Dardzinski,B.G. Collins, C.M.Collins, Q. X. Yang, V. J. Schmithorst, and M. B. Smith, "Spatial variation in cartilage T2 of the knee," J. Magn. Reson. Imag., vol. 14, pp. 50-55, 2001
-
(2001)
J. Magn. Reson. Imag
, vol.14
, pp. 50-55
-
-
Smith, H.E.1
Mosher, T.J.2
Dardzinski, B.G.3
Collins, B.J.4
Collins, C.M.5
Yang, Q.X.6
Schmithorst, V.J.7
Smith, M.B.8
-
10
-
-
76549128409
-
Functional cartilage MRI T2 mapping: Evaluating the effect of age and training on knee cartilage response to running
-
T. J. Mosher, Y. Liu, and C. M. Torok, "Functional cartilage MRI T2 mapping: Evaluating the effect of age and training on knee cartilage response to running," Osteo. Cart., vol. 18, pp. 358-364, 2010
-
(2010)
Osteo. Cart
, vol.18
, pp. 358-364
-
-
Mosher, T.J.1
Liu, Y.2
Torok, C.M.3
-
11
-
-
33947578726
-
Analytical derivation of multiple spin echo amplitudeswith arbitrary refocusing angle
-
N. N. Lukzen and A. A. Savelov, "Analytical derivation of multiple spin echo amplitudeswith arbitrary refocusing angle," J. Magn. Reson., vol. 185, pp. 71-76, 2007
-
(2007)
J. Magn. Reson
, vol.185
, pp. 71-76
-
-
Lukzen, N.N.1
Savelov, A.A.2
-
12
-
-
84921438757
-
Closed-form solution for t2 mapping with nonideal refocusing of slice-selective cpmg sequences
-
A. Petrovic, E. Scheurer, and R. Stollberger, "Closed-form solution for T2 mapping with nonideal refocusing of slice-selective CPMG sequences," Magn. Reson. Med., 2014
-
(2014)
Magn. Reson. Med
-
-
Petrovic, A.1
Scheurer, E.2
Stollberger, R.3
-
13
-
-
84914104532
-
Nonlinear inverse reconstruction for T2 mapping using the generating function formalism on undersampled Cartesian Data
-
T. J. Sumpf, F. Knoll, J. Frahm, R. Stollberger, and A. Petrovic, "Nonlinear inverse reconstruction for T2 mapping using the generating function formalism on undersampled Cartesian Data," in Proc. 20th Ann. Meet. ISMRM, 2012, p. 2398
-
(2012)
Proc. 20th Ann. Meet. ISMRM
, pp. 2398
-
-
Sumpf, T.J.1
Knoll, F.2
Frahm, J.3
Stollberger, R.4
Petrovic, A.5
-
14
-
-
84885316340
-
T2 relaxometry with indirect echo compensation from highly undersampled data
-
C. Huang, A. Bilgin, T. Barr, and M. I. Altbach, "T2 relaxometry with indirect echo compensation from highly undersampled data," Magn. Reson. Med., vol. 70, pp. 1026-1037, 2013
-
(2013)
Magn. Reson. Med
, vol.70
, pp. 1026-1037
-
-
Huang, C.1
Bilgin, A.2
Barr, T.3
Altbach, M.I.4
-
15
-
-
84914104531
-
Fast, artifact-free T2 mapping with fast spin echo using the extended phase graph and joint parameter reconstruction
-
Salt Lake City, UT
-
C. L. Lankford and M. D. Does, "Fast, artifact-free T2 mapping with fast spin echo using the extended phase graph and joint parameter reconstruction," in Proc. 21th Annu. Meet. ISMRM, Salt Lake City, UT, 2013, p. 2461
-
(2013)
Proc. 21th Annu. Meet. ISMRM
, pp. 2461
-
-
Lankford, C.L.1
Does, M.D.2
-
16
-
-
0000811634
-
Multiecho imaging sequences with low refocusing flip angles
-
J. Hennig, "Multiecho imaging sequences with low refocusing flip angles," J. Magn. Reson., vol. 78, pp. 397-407, 1988
-
(1988)
J. Magn. Reson
, vol.78
, pp. 397-407
-
-
Hennig, J.1
-
17
-
-
84985848260
-
Echoes-How to generate, recognize, use or avoid them in MR-imaging sequences Part I: Fundamental and not so fundamental properties of spin echoes
-
J. Hennig, "Echoes-How to generate, recognize, use or avoid them in MR-imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes," Conc. Magn. Reson., vol. 3, pp. 125-143, 2005
-
(2005)
Conc. Magn. Reson
, vol.3
, pp. 125-143
-
-
Hennig, J.1
-
18
-
-
0001423628
-
Effects of diffusion in nuclear magnetic resonance spin-echo experiments
-
D. E. Woessner, "Effects of diffusion in nuclear magnetic resonance spin-echo experiments," J. Chem. Phys., vol. 34, p. 2057, 1961
-
(1961)
J. Chem. Phys
, vol.34
, pp. 2057
-
-
Woessner, D.E.1
-
19
-
-
0141839035
-
Calculation of diffusion effect for arbitrary pulse sequences
-
V. G. Kiselev, "Calculation of diffusion effect for arbitrary pulse sequences," J. Magn. Reson., vol. 164, pp. 205-211, 2003
-
(2003)
J. Magn. Reson
, vol.164
, pp. 205-211
-
-
Kiselev, V.G.1
-
20
-
-
7544243937
-
An algorithm to calculate the NMR signal of a multi spinecho sequence with relaxation and spin-diffusion
-
Y. Zur, "An algorithm to calculate the NMR signal of a multi spinecho sequence with relaxation and spin-diffusion," J. Magn. Reson., vol. 171, pp. 97-106, 2004
-
(2004)
J. Magn. Reson
, vol.171
, pp. 97-106
-
-
Zur, Y.1
-
21
-
-
77957322539
-
Transverse relaxometry with stimulated echo compensation
-
R. M. Lebel and A. H. Wilman, "Transverse relaxometry with stimulated echo compensation,"Magn. Reson. Med., vol. 64, pp. 1005-1014, 2010
-
(2010)
Magn. Reson. Med
, vol.64
, pp. 1005-1014
-
-
Lebel, R.M.1
Wilman, A.H.2
-
24
-
-
0026914023
-
Practical T2 quantitation for clinical applications
-
C. S. Poon and R.M. Henkelman, "Practical T2 quantitation for clinical applications," J. Mag. Resonance Imag., vol. 2, pp. 541-553, 1992
-
(1992)
J. Mag. Resonance Imag
, vol.2
, pp. 541-553
-
-
Poon, C.S.1
Henkelman, R.M.2
-
25
-
-
33144465578
-
A new conjugate gradient method with guaranteed descent and an efficient line search siam
-
W.W. Hager and H. A. Zhang, "A new conjugate gradient method with guaranteed descent and an efficient line search," SIAM J. Optim., vol. 16, pp. 170-192, 2006
-
(2006)
J. Optim
, vol.16
, pp. 170-192
-
-
Hager, W.W.1
Zhang, H.A.2
-
27
-
-
0034351120
-
Reconstruction of mr images from data acquired on a general nonregular grid by pseudoinverse calculation
-
Dec
-
R. Van DeWalle, H. H. Barrett, K. J.Myers,M. I. Altbach, B. Desplanques, A. F. Gmitro, J. Cornelis, and I. Lemahieu, "Reconstruction of MR images from data acquired on a general nonregular grid by pseudoinverse calculation," IEEE Trans. Med. Imag., vol. 19, no. 12, pp. 1160-1167, Dec. 2000
-
(2000)
IEEE Trans. Med. Imag
, vol.19
, Issue.12
, pp. 1160-1167
-
-
Walle De R.Van1
Barrett, H.H.2
Myers, K.J.3
Altbach, M.I.4
Desplanques, B.5
Gmitro, A.F.6
Cornelis, J.7
Lemahieu, I.8
-
28
-
-
77955289545
-
B1 mapping by Bloch-Siegert shift
-
L. I. Sacolick, F. Wiesinger, I. Hancu, and M. W. Vogel, "B1 mapping by Bloch-Siegert shift," Magn. Reson. Med., vol. 63, pp. 1315-1322, 2010
-
(2010)
Magn. Reson. Med
, vol.63
, pp. 1315-1322
-
-
Sacolick, L.I.1
Wiesinger, F.2
Hancu, I.3
Vogel, M.W.4
-
29
-
-
51449090553
-
Image reconstruction by regularized nonlinear inversion-Joint estimation of coil sensitivities and image content
-
M. Uecker, T. Hohage, K. T. Block, and J. Frahm, "Image reconstruction by regularized nonlinear inversion-Joint estimation of coil sensitivities and image content," Magn. Reson. Med., vol. 60, pp. 674-682, 2008
-
(2008)
Magn. Reson. Med
, vol.60
, pp. 674-682
-
-
Uecker, M.1
Hohage, T.2
Block, K.T.3
Frahm, J.4
|