Volumn 33, Issue 12, 2014, Pages 2213-2222

Fast T2 mapping with improved accuracy using undersampled spin-echo MRI and model-based reconstructions with a generating function

Author keywords

Fast spin echo (FSE); indirect echoes; model based reconstruction; relaxometry; T2 mapping

Indexed keywords

ALGORITHM; ANATOMY AND HISTOLOGY; BRAIN; BRAIN MAPPING; FACTUAL DATABASE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PROCEDURES;

EID: 84914127116     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2014.2333370     Document Type: Article
Times cited : (62)

References (29)
  • 1
    • 84866426598 scopus 로고    scopus 로고
    • Practical medical applications of quantitativeMR relaxometry
    • H. M. Cheng, N. Stikov, N. R. Ghugre, and G. A. Wright, "Practical medical applications of quantitativeMR relaxometry," J. Magn. Reson. Imag., vol. 36, pp. 805-824, 2012
    • (2012) J. Magn. Reson. Imag , vol.36 , pp. 805-824
    • Cheng, H.M.1    Stikov, N.2    Ghugre, N.R.3    Wright, G.A.4
  • 2
    • 70350751580 scopus 로고    scopus 로고
    • Model-based iterative reconstruction for radial fast spin-echo MRI
    • Nov
    • K. T. Block, M. Uecker, and J. Frahm, "Model-based iterative reconstruction for radial fast spin-echo MRI," IEEE Trans. Med. Imag., vol. 28, no. 11, pp. 1759-1769, Nov. 2009
    • (2009) IEEE Trans. Med. Imag , vol.28 , Issue.11 , pp. 1759-1769
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 4
    • 79960611551 scopus 로고    scopus 로고
    • Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI
    • T. J. Sumpf, M. Uecker, S. Boretius, and J. Frahm, "Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI," J. Magn. Reson. Imag., vol. 34, pp. 420-428, 2011
    • (2011) J. Magn. Reson. Imag , vol.34 , pp. 420-428
    • Sumpf, T.J.1    Uecker, M.2    Boretius, S.3    Frahm, J.4
  • 5
    • 84859719425 scopus 로고    scopus 로고
    • T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing
    • C. Huang, C. G. Graff, E.W. Clarkson, A. Bilgin, andM. I. Altbach, "T2 mapping from highly undersampled data by reconstruction of principal component coefficient maps using compressed sensing," Magn. Reson. Med., vol. 67, pp. 1355-1366, 2012
    • (2012) Magn. Reson. Med , vol.67 , pp. 1355-1366
    • Huang, C.1    Graff, C.G.2    Clarkson, E.W.3    Bilgin, A.4    Altbach, M.I.5
  • 6
    • 0022555963 scopus 로고
    • Errors in the measurements of T2 using multiple-echo MRI techniques 1 Effects of radiofrequency pulse imperfections
    • S. Majumdar, S. C. Orphanoudakis, A. Gmitro, M. Odonnell, and J. C. Gore, "Errors in the measurements of T2 using multiple-echo MRI techniques. 1. Effects of radiofrequency pulse imperfections," Magn. Reson. Med., vol. 3, pp. 397-417, 1986
    • (1986) Magn. Reson. Med , vol.3 , pp. 397-417
    • Majumdar, S.1    Orphanoudakis, S.C.2    Gmitro, A.3    Odonnell, M.4    Gore, J.C.5
  • 7
    • 0022930453 scopus 로고
    • Errors in the measurements of T2 using multiple-echo MRI techniques 2 Effects of static-field inhomogeneity
    • S. Majumdar, S. C. Orphanoudakis, A. Gmitro, M. Odonnell, and J. C. Gore, "Errors in the measurements of T2 using multiple-echo MRI techniques. 2. Effects of static-field inhomogeneity," Magn. Reson. Med., vol. 3, pp. 562-574, 1986
    • (1986) Magn. Reson. Med , vol.3 , pp. 562-574
    • Majumdar, S.1    Orphanoudakis, S.C.2    Gmitro, A.3    Odonnell, M.4    Gore, J.C.5
  • 8
    • 0023164952 scopus 로고
    • Errors in T2 estimation using multislice multiple-echo imaging
    • A. P. Crawley and R. M. Henkelman, "Errors in T2 estimation using multislice multiple-echo imaging," Magn. Reson. Med., vol. 4, pp. 34-47, 1987
    • (1987) Magn. Reson. Med , vol.4 , pp. 34-47
    • Crawley, A.P.1    Henkelman, R.M.2
  • 10
    • 76549128409 scopus 로고    scopus 로고
    • Functional cartilage MRI T2 mapping: Evaluating the effect of age and training on knee cartilage response to running
    • T. J. Mosher, Y. Liu, and C. M. Torok, "Functional cartilage MRI T2 mapping: Evaluating the effect of age and training on knee cartilage response to running," Osteo. Cart., vol. 18, pp. 358-364, 2010
    • (2010) Osteo. Cart , vol.18 , pp. 358-364
    • Mosher, T.J.1    Liu, Y.2    Torok, C.M.3
  • 11
    • 33947578726 scopus 로고    scopus 로고
    • Analytical derivation of multiple spin echo amplitudeswith arbitrary refocusing angle
    • N. N. Lukzen and A. A. Savelov, "Analytical derivation of multiple spin echo amplitudeswith arbitrary refocusing angle," J. Magn. Reson., vol. 185, pp. 71-76, 2007
    • (2007) J. Magn. Reson , vol.185 , pp. 71-76
    • Lukzen, N.N.1    Savelov, A.A.2
  • 12
    • 84921438757 scopus 로고    scopus 로고
    • Closed-form solution for t2 mapping with nonideal refocusing of slice-selective cpmg sequences
    • A. Petrovic, E. Scheurer, and R. Stollberger, "Closed-form solution for T2 mapping with nonideal refocusing of slice-selective CPMG sequences," Magn. Reson. Med., 2014
    • (2014) Magn. Reson. Med
    • Petrovic, A.1    Scheurer, E.2    Stollberger, R.3
  • 13
    • 84914104532 scopus 로고    scopus 로고
    • Nonlinear inverse reconstruction for T2 mapping using the generating function formalism on undersampled Cartesian Data
    • T. J. Sumpf, F. Knoll, J. Frahm, R. Stollberger, and A. Petrovic, "Nonlinear inverse reconstruction for T2 mapping using the generating function formalism on undersampled Cartesian Data," in Proc. 20th Ann. Meet. ISMRM, 2012, p. 2398
    • (2012) Proc. 20th Ann. Meet. ISMRM , pp. 2398
    • Sumpf, T.J.1    Knoll, F.2    Frahm, J.3    Stollberger, R.4    Petrovic, A.5
  • 14
    • 84885316340 scopus 로고    scopus 로고
    • T2 relaxometry with indirect echo compensation from highly undersampled data
    • C. Huang, A. Bilgin, T. Barr, and M. I. Altbach, "T2 relaxometry with indirect echo compensation from highly undersampled data," Magn. Reson. Med., vol. 70, pp. 1026-1037, 2013
    • (2013) Magn. Reson. Med , vol.70 , pp. 1026-1037
    • Huang, C.1    Bilgin, A.2    Barr, T.3    Altbach, M.I.4
  • 15
    • 84914104531 scopus 로고    scopus 로고
    • Fast, artifact-free T2 mapping with fast spin echo using the extended phase graph and joint parameter reconstruction
    • Salt Lake City, UT
    • C. L. Lankford and M. D. Does, "Fast, artifact-free T2 mapping with fast spin echo using the extended phase graph and joint parameter reconstruction," in Proc. 21th Annu. Meet. ISMRM, Salt Lake City, UT, 2013, p. 2461
    • (2013) Proc. 21th Annu. Meet. ISMRM , pp. 2461
    • Lankford, C.L.1    Does, M.D.2
  • 16
    • 0000811634 scopus 로고
    • Multiecho imaging sequences with low refocusing flip angles
    • J. Hennig, "Multiecho imaging sequences with low refocusing flip angles," J. Magn. Reson., vol. 78, pp. 397-407, 1988
    • (1988) J. Magn. Reson , vol.78 , pp. 397-407
    • Hennig, J.1
  • 17
    • 84985848260 scopus 로고    scopus 로고
    • Echoes-How to generate, recognize, use or avoid them in MR-imaging sequences Part I: Fundamental and not so fundamental properties of spin echoes
    • J. Hennig, "Echoes-How to generate, recognize, use or avoid them in MR-imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes," Conc. Magn. Reson., vol. 3, pp. 125-143, 2005
    • (2005) Conc. Magn. Reson , vol.3 , pp. 125-143
    • Hennig, J.1
  • 18
    • 0001423628 scopus 로고
    • Effects of diffusion in nuclear magnetic resonance spin-echo experiments
    • D. E. Woessner, "Effects of diffusion in nuclear magnetic resonance spin-echo experiments," J. Chem. Phys., vol. 34, p. 2057, 1961
    • (1961) J. Chem. Phys , vol.34 , pp. 2057
    • Woessner, D.E.1
  • 19
    • 0141839035 scopus 로고    scopus 로고
    • Calculation of diffusion effect for arbitrary pulse sequences
    • V. G. Kiselev, "Calculation of diffusion effect for arbitrary pulse sequences," J. Magn. Reson., vol. 164, pp. 205-211, 2003
    • (2003) J. Magn. Reson , vol.164 , pp. 205-211
    • Kiselev, V.G.1
  • 20
    • 7544243937 scopus 로고    scopus 로고
    • An algorithm to calculate the NMR signal of a multi spinecho sequence with relaxation and spin-diffusion
    • Y. Zur, "An algorithm to calculate the NMR signal of a multi spinecho sequence with relaxation and spin-diffusion," J. Magn. Reson., vol. 171, pp. 97-106, 2004
    • (2004) J. Magn. Reson , vol.171 , pp. 97-106
    • Zur, Y.1
  • 21
    • 77957322539 scopus 로고    scopus 로고
    • Transverse relaxometry with stimulated echo compensation
    • R. M. Lebel and A. H. Wilman, "Transverse relaxometry with stimulated echo compensation,"Magn. Reson. Med., vol. 64, pp. 1005-1014, 2010
    • (2010) Magn. Reson. Med , vol.64 , pp. 1005-1014
    • Lebel, R.M.1    Wilman, A.H.2
  • 24
    • 0026914023 scopus 로고
    • Practical T2 quantitation for clinical applications
    • C. S. Poon and R.M. Henkelman, "Practical T2 quantitation for clinical applications," J. Mag. Resonance Imag., vol. 2, pp. 541-553, 1992
    • (1992) J. Mag. Resonance Imag , vol.2 , pp. 541-553
    • Poon, C.S.1    Henkelman, R.M.2
  • 25
    • 33144465578 scopus 로고    scopus 로고
    • A new conjugate gradient method with guaranteed descent and an efficient line search siam
    • W.W. Hager and H. A. Zhang, "A new conjugate gradient method with guaranteed descent and an efficient line search," SIAM J. Optim., vol. 16, pp. 170-192, 2006
    • (2006) J. Optim , vol.16 , pp. 170-192
    • Hager, W.W.1    Zhang, H.A.2
  • 29
    • 51449090553 scopus 로고    scopus 로고
    • Image reconstruction by regularized nonlinear inversion-Joint estimation of coil sensitivities and image content
    • M. Uecker, T. Hohage, K. T. Block, and J. Frahm, "Image reconstruction by regularized nonlinear inversion-Joint estimation of coil sensitivities and image content," Magn. Reson. Med., vol. 60, pp. 674-682, 2008
    • (2008) Magn. Reson. Med , vol.60 , pp. 674-682
    • Uecker, M.1    Hohage, T.2    Block, K.T.3    Frahm, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.