메뉴 건너뛰기




Volumn 208, Issue , 2015, Pages 505-511

Direct electrochemistry of cholesterol oxidase immobilized on chitosan-graphene and cholesterol sensing

Author keywords

Chitosan graphene nanocomposites; Cholesterol biosensor; Direct electrochemistry; Graphene oxide; Microwave method; Situ reduction

Indexed keywords

CHITOSAN; CHOLESTEROL; ELECTROCHEMISTRY; ELECTRODES; ENZYME ELECTRODES; ENZYME IMMOBILIZATION; GLASS MEMBRANE ELECTRODES; GLASSY CARBON; NANOCOMPOSITES; RATE CONSTANTS; REDUCTION; TRANSMISSION ELECTRON MICROSCOPY;

EID: 84912124584     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.11.054     Document Type: Article
Times cited : (87)

References (35)
  • 3
    • 69249115761 scopus 로고    scopus 로고
    • Electrochemical oxidation of cholesterol in acetonitrile leads to the formation of cholesta-4,6-dien-3-one
    • Y.Y. Hosokawa, H. Hakamata, T. Murakami, S. Aoyagi, Electrochemical oxidation of cholesterol in acetonitrile leads to the formation of cholesta-4,6-dien-3-one, Electrochim. Acta 54 (2009) 6412-6416.
    • (2009) Electrochim. Acta , vol.54 , pp. 6412-6416
    • Hosokawa, Y.Y.1    Hakamata, H.2    Murakami, T.3    Aoyagi, S.4
  • 4
    • 47249149766 scopus 로고    scopus 로고
    • Fluorescence and electrochemistry studies of pyrene-functionalized surface adlayers to probe the microenvironment formed by cholesterol
    • L.P. Ding, M. Domińska, Y. Fang, G.J. Blanchard, Fluorescence and electrochemistry studies of pyrene-functionalized surface adlayers to probe the microenvironment formed by cholesterol, Electrochim. Acta 53 (2008) 6704-6713.
    • (2008) Electrochim. Acta , vol.53 , pp. 6704-6713
    • Ding, L.P.1    Domińska, M.2    Fang, Y.3    Blanchard, G.J.4
  • 5
    • 84861233430 scopus 로고    scopus 로고
    • Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods
    • C.Y. Wang, X.R. Tan, S.H. Chen, Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods, Talanta 94 (2012) 263-270.
    • (2012) Talanta , vol.94 , pp. 263-270
    • Wang, C.Y.1    Tan, X.R.2    Chen, S.H.3
  • 6
    • 84887365996 scopus 로고    scopus 로고
    • Electrochemistry of cholesterol biosensor based on a novel Pt-Pd bimetallic nanoparticle decorated graphene catalyst
    • S.R. Cao, L. Zhang, Y.Q. Chai, R. Yuan, Electrochemistry of cholesterol biosensor based on a novel Pt-Pd bimetallic nanoparticle decorated graphene catalyst, Talanta 109 (2013) 167-172.
    • (2013) Talanta , vol.109 , pp. 167-172
    • Cao, S.R.1    Zhang, L.2    Chai, Y.Q.3    Yuan, R.4
  • 7
    • 74549131187 scopus 로고    scopus 로고
    • A novel capacitive biosensor for cholesterol assay that uses an electropolymerized molecularly imprinted polymer
    • A. Aghaei, M.R.M. Hosseini, M. Najafi, A novel capacitive biosensor for cholesterol assay that uses an electropolymerized molecularly imprinted polymer, Electrochim. Acta 55 (2010) 1503-1508.
    • (2010) Electrochim. Acta , vol.55 , pp. 1503-1508
    • Aghaei, A.1    Hosseini, M.R.M.2    Najafi, M.3
  • 8
    • 14644411715 scopus 로고    scopus 로고
    • Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood
    • G. Li, J.M. Liao, G.Q. Hu, N.Z. Ma, P.J. Wu, Study of carbon nanotube modified biosensor for monitoring total cholesterol in blood, Biosens. Bioelectron. 20 (2005) 2140-2144.
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 2140-2144
    • Li, G.1    Liao, J.M.2    Hu, G.Q.3    Ma, N.Z.4    Wu, P.J.5
  • 9
    • 0345802624 scopus 로고    scopus 로고
    • Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films
    • S. Singh, A. Chaubey, B.D. Malhotra, Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films, Anal. Chim. Acta 502 (2004) 229-234.
    • (2004) Anal. Chim. Acta , vol.502 , pp. 229-234
    • Singh, S.1    Chaubey, A.2    Malhotra, B.D.3
  • 10
    • 77949654696 scopus 로고    scopus 로고
    • A new amperometric cholesterol biosensor based on poly(3,4-ethylenedioxypyrrole)
    • O. Türkarslan, S.K. Kayahan, L. Toppare, A new amperometric cholesterol biosensor based on poly(3,4-ethylenedioxypyrrole), Sens. Actuators B 136 (2009) 484-488.
    • (2009) Sens. Actuators B , vol.136 , pp. 484-488
    • Türkarslan, O.1    Kayahan, S.K.2    Toppare, L.3
  • 11
    • 84871867385 scopus 로고    scopus 로고
    • Hydrophobic ionic liquid immoblizing cholesterol oxidase on the electrodeposited Prussian blue on glassy carbon electrode for detection of cholesterol
    • X.H. Liu, Z.H. Nan, Y. Qiu, L.C. Zheng, X.Q. Lu, Hydrophobic ionic liquid immoblizing cholesterol oxidase on the electrodeposited Prussian blue on glassy carbon electrode for detection of cholesterol, Electrochim. Acta 90 (2013) 203-209.
    • (2013) Electrochim. Acta , vol.90 , pp. 203-209
    • Liu, X.H.1    Nan, Z.H.2    Qiu, Y.3    Zheng, L.C.4    Lu, X.Q.5
  • 12
    • 78651355102 scopus 로고    scopus 로고
    • Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples
    • U. Saxena, M. Chakraborty, P. Goswami, Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples, Biosens. Bioelectron. 26 (2011) 3037-3043.
    • (2011) Biosens. Bioelectron. , vol.26 , pp. 3037-3043
    • Saxena, U.1    Chakraborty, M.2    Goswami, P.3
  • 13
    • 0019634405 scopus 로고
    • Immobilized enzyme chemically modified electrode as an amperometric sensor
    • R.M. Ianniello, A.M. Yacynych, Immobilized enzyme chemically modified electrode as an amperometric sensor, Anal. Chem. 53 (1981) 2090-2095.
    • (1981) Anal. Chem. , vol.53 , pp. 2090-2095
    • Ianniello, R.M.1    Yacynych, A.M.2
  • 14
    • 0033106016 scopus 로고    scopus 로고
    • Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator
    • T. Nakaminami, S. Ito, S. Kuwabata, H. Yoneyama, Amperometric determination of total cholesterol at gold electrodes covalently modified with cholesterol oxidase and cholesterol esterase with use of thionin as an electron mediator, Anal. Chem. 71 (1999) 1068-1076.
    • (1999) Anal. Chem. , vol.71 , pp. 1068-1076
    • Nakaminami, T.1    Ito, S.2    Kuwabata, S.3    Yoneyama, H.4
  • 15
    • 70349878360 scopus 로고    scopus 로고
    • Metal oxide-chitosan based nanocomposite for cholesterol biosensor
    • B.D. Malhotra, A. Kaushik, Metal oxide-chitosan based nanocomposite for cholesterol biosensor, Thin Solid Films 518 (2009) 614-620.
    • (2009) Thin Solid Films , vol.518 , pp. 614-620
    • Malhotra, B.D.1    Kaushik, A.2
  • 16
    • 80053239966 scopus 로고    scopus 로고
    • Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor
    • X.R. Li, J.J. Xu, H.Y. Chen, Potassium-doped carbon nanotubes toward the direct electrochemistry of cholesterol oxidase and its application in highly sensitive cholesterol biosensor, Electrochim. Acta 56 (2011) 9378-9385.
    • (2011) Electrochim. Acta , vol.56 , pp. 9378-9385
    • Li, X.R.1    Xu, J.J.2    Chen, H.Y.3
  • 18
    • 84866251800 scopus 로고    scopus 로고
    • An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination
    • R. Manjunatha, G.S. Suresh, J.S. Melo, S.F. D'Souza, T.V. Venkatesha, An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination, Talanta 99 (2012) 302-309.
    • (2012) Talanta , vol.99 , pp. 302-309
    • Manjunatha, R.1    Suresh, G.S.2    Melo, J.S.3    D'Souza, S.F.4    Venkatesha, T.V.5
  • 19
    • 84871648160 scopus 로고    scopus 로고
    • An integrated sensing system for detection of cholesterol based on TiO2-graphene-Pt-Pd hybrid nanocomposites
    • S.R. Cao, L. Zhang, Y.Q. Chai, R. Yuan, An integrated sensing system for detection of cholesterol based on TiO2-graphene-Pt-Pd hybrid nanocomposites, Biosens. Bioelectron. 42 (2013) 532-538.
    • (2013) Biosens. Bioelectron. , vol.42 , pp. 532-538
    • Cao, S.R.1    Zhang, L.2    Chai, Y.Q.3    Yuan, R.4
  • 21
    • 84885368745 scopus 로고    scopus 로고
    • Electrochemical co-reduction synthesis of graphene/nano-gold composites and its application to electrochemical glucose biosensor
    • X.L. Wang, X.L. Zhang, Electrochemical co-reduction synthesis of graphene/nano-gold composites and its application to electrochemical glucose biosensor, Electrochim. Acta 112 (2013) 774-782.
    • (2013) Electrochim. Acta , vol.112 , pp. 774-782
    • Wang, X.L.1    Zhang, X.L.2
  • 23
    • 84878433992 scopus 로고    scopus 로고
    • Electrochemical determination of 4-nonylphenol on graphene-chitosan modified glassy carbon electrode
    • W.S. Zhou, B. Zhao, X.H. Huang, X.D. Yang, Electrochemical determination of 4-nonylphenol on graphene-chitosan modified glassy carbon electrode, Chin. J. Anal. Chem. 41 (2013) 675-680.
    • (2013) Chin. J. Anal. Chem. , vol.41 , pp. 675-680
    • Zhou, W.S.1    Zhao, B.2    Huang, X.H.3    Yang, X.D.4
  • 24
    • 70350394842 scopus 로고    scopus 로고
    • Glucose oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing
    • X.H. Kang, J. Wang, H. Wu, A.A. Ilhan, J. Liu, Y.H. Lin, Glucose oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing, Biosens. Bioelectron. 25 (2009) 901-905.
    • (2009) Biosens. Bioelectron. , vol.25 , pp. 901-905
    • Kang, X.H.1    Wang, J.2    Wu, H.3    Ilhan, A.A.4    Liu, J.5    Lin, Y.H.6
  • 26
    • 67650744584 scopus 로고    scopus 로고
    • Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide
    • M. Zhou, Y.M. Zhai, S.J. Dong, Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide, Anal. Chem. 81 (2009) 5603-5613.
    • (2009) Anal. Chem. , vol.81 , pp. 5603-5613
    • Zhou, M.1    Zhai, Y.M.2    Dong, S.J.3
  • 27
    • 0001709746 scopus 로고
    • Electron transfer kinetics with both reactant and product attached to the electrode surface
    • A.P. Brown, F.C. Anson, Electron transfer kinetics with both reactant and product attached to the electrode surface, J. Electroanal. Chem. 92 (1978) 133-145.
    • (1978) J. Electroanal. Chem. , vol.92 , pp. 133-145
    • Brown, A.P.1    Anson, F.C.2
  • 28
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Laviron, General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems, J. Electroanal. Chem. 101 (1979) 19-28.
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Laviron, E.1
  • 30
    • 33846406881 scopus 로고    scopus 로고
    • Electrochemical characteristics of glucose oxidase adsorbed at carbon nanotubes modified electrode with ionic liquid as binder
    • Y. Liu, L. Liu, S. Dong, Electrochemical characteristics of glucose oxidase adsorbed at carbon nanotubes modified electrode with ionic liquid as binder, Electroanalysis 19 (2007) 55-59.
    • (2007) Electroanalysis , vol.19 , pp. 55-59
    • Liu, Y.1    Liu, L.2    Dong, S.3
  • 31
    • 84872711595 scopus 로고    scopus 로고
    • Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing
    • L. Zhu, L.L. Xu, L. Tan, H. Tan, Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing, Talanta 106 (2013) 192-199.
    • (2013) Talanta , vol.106 , pp. 192-199
    • Zhu, L.1    Xu, L.L.2    Tan, L.3    Tan, H.4
  • 32
    • 0001246355 scopus 로고
    • Enzyme-substrate kinetics of adsorbed cytochrome c peroxidase on pyrolytic graphite electrodes
    • D.L. Scott, E.F. Bowden, Enzyme-substrate kinetics of adsorbed cytochrome c peroxidase on pyrolytic graphite electrodes, Anal. Chem. 66 (1994) 1217-1223.
    • (1994) Anal. Chem. , vol.66 , pp. 1217-1223
    • Scott, D.L.1    Bowden, E.F.2
  • 33
    • 79959261875 scopus 로고    scopus 로고
    • Self-assembled graphene platelet-glucose oxidase nanostructures for glucose biosensing
    • S. Liu, J. Tian, L. Wang, Y. Luo, W. Lu, X. Sun, Self-assembled graphene platelet-glucose oxidase nanostructures for glucose biosensing, Biosens. Bioelectron. 26 (2011) 4491-4496.
    • (2011) Biosens. Bioelectron. , vol.26 , pp. 4491-4496
    • Liu, S.1    Tian, J.2    Wang, L.3    Luo, Y.4    Lu, W.5    Sun, X.6
  • 34
    • 84857563826 scopus 로고    scopus 로고
    • Electrophoretically deposited CdS quantum dots based electrode for biosensor application
    • H. Dhyani, M.A. Ali, M.K. Pandey, B.D. Malhotra, P. Sen, Electrophoretically deposited CdS quantum dots based electrode for biosensor application, J. Mater. Chem. 22 (2012) 4970-4976.
    • (2012) J. Mater. Chem. , vol.22 , pp. 4970-4976
    • Dhyani, H.1    Ali, M.A.2    Pandey, M.K.3    Malhotra, B.D.4    Sen, P.5
  • 35
    • 79959846600 scopus 로고    scopus 로고
    • Fabrication of a cholesterol biosensor based on cholesterol oxidase and multiwall carbon nanotube hybrid composites
    • J.Y. Yang, Y. Li, S.M. Chen, K.C. Lin, Fabrication of a cholesterol biosensor based on cholesterol oxidase and multiwall carbon nanotube hybrid composites, Int. J. Electrochem. Sci. 6 (2011) 2223-2234.
    • (2011) Int. J. Electrochem. Sci. , vol.6 , pp. 2223-2234
    • Yang, J.Y.1    Li, Y.2    Chen, S.M.3    Lin, K.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.