-
1
-
-
68249143113
-
Quality of care after distal radius fracture in Germany. Results of a fracture register of 1,201 elderly patients
-
COI: 1:STN:280:DC%2BD1M7ksF2htg%3D%3D, PID: 19104764
-
Smektala R, Endres HG, Dasch B, Bonnaire F, Trampisch HJ, Pientka L (2009) Quality of care after distal radius fracture in Germany. Results of a fracture register of 1,201 elderly patients. Unfallchirurg 112(1):46–54. doi:10.1007/s00113-008-1523-8
-
(2009)
Unfallchirurg
, vol.112
, Issue.1
, pp. 46-54
-
-
Smektala, R.1
Endres, H.G.2
Dasch, B.3
Bonnaire, F.4
Trampisch, H.J.5
Pientka, L.6
-
2
-
-
70350759758
-
Distal radius fractures
-
PID: 19858984
-
Liporace FA, Adams MR, Capo JT, Koval KJ (2009) Distal radius fractures. J Orthop Trauma 23(10):739–748. doi:10.1097/BOT.0b013e3181ba46d3
-
(2009)
J Orthop Trauma
, vol.23
, Issue.10
, pp. 739-748
-
-
Liporace, F.A.1
Adams, M.R.2
Capo, J.T.3
Koval, K.J.4
-
3
-
-
34548439901
-
Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study
-
PID: 17826546
-
Rein S, Schikore H, Schneiders W, Amlang M, Zwipp H (2007) Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am 32(7):954–961. doi:10.1016/j.jhsa.2007.05.008
-
(2007)
J Hand Surg Am
, vol.32
, Issue.7
, pp. 954-961
-
-
Rein, S.1
Schikore, H.2
Schneiders, W.3
Amlang, M.4
Zwipp, H.5
-
4
-
-
77950347662
-
Operative management of distal radial fractures with 2.4-millimeter locking plates: a multicenter prospective case series. Surgical technique
-
PID: 20194348
-
Jupiter JB, Marent-Huber M (2010) Operative management of distal radial fractures with 2.4-millimeter locking plates: a multicenter prospective case series. Surgical technique. J Bone Joint Surg Am 92((Suppl 1 Pt 1)):96–106. doi:10.2106/jbjs.i.01340
-
(2010)
J Bone Joint Surg Am
, vol.92
, pp. 96-106
-
-
Jupiter, J.B.1
Marent-Huber, M.2
-
5
-
-
0030025204
-
X-ray film measurements for healed distal radius fractures
-
COI: 1:STN:280:DyaK28zntFemug%3D%3D, PID: 8775193
-
Kreder HJ, Hanel DP, McKee M, Jupiter J, McGillivary G, Swiontkowski MF (1996) X-ray film measurements for healed distal radius fractures. J Hand Surg Am 21(1):31–39. doi:10.1016/s0363-5023(96)80151-1
-
(1996)
J Hand Surg Am
, vol.21
, Issue.1
, pp. 31-39
-
-
Kreder, H.J.1
Hanel, D.P.2
McKee, M.3
Jupiter, J.4
McGillivary, G.5
Swiontkowski, M.F.6
-
6
-
-
34547581677
-
Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study
-
Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN (2007) Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y) 2(3):144–150. doi:10.1007/s11552-007-9038-2
-
(2007)
Hand (N Y)
, vol.2
, Issue.3
, pp. 144-150
-
-
Maschke, S.D.1
Evans, P.J.2
Schub, D.3
Drake, R.4
Lawton, J.N.5
-
7
-
-
79551618985
-
Influence of screw diameter and number on reduction loss after plating of distal radius fractures
-
PID: 21299798
-
Drobetz H, Schueller M, Tschegg EK, Heal C, Redl H, Muller R (2011) Influence of screw diameter and number on reduction loss after plating of distal radius fractures. ANZ J Surg 81(1–2):46–51. doi:10.1111/j.1445-2197.2010.05479.x
-
(2011)
ANZ J Surg
, vol.81
, Issue.1-2
, pp. 46-51
-
-
Drobetz, H.1
Schueller, M.2
Tschegg, E.K.3
Heal, C.4
Redl, H.5
Muller, R.6
-
8
-
-
77953290755
-
Clinical and radiological outcomes after stabilisation of complex intra-articular fractures of the distal radius with the volar 2.4 mm LCP
-
PID: 19894054
-
Konstantinidis L, Helwig P, Strohm PC, Hirschmuller A, Kron P, Sudkamp NP (2010) Clinical and radiological outcomes after stabilisation of complex intra-articular fractures of the distal radius with the volar 2.4 mm LCP. Arch Orthop Trauma Surg 130(6):751–757. doi:10.1007/s00402-009-0990-x
-
(2010)
Arch Orthop Trauma Surg
, vol.130
, Issue.6
, pp. 751-757
-
-
Konstantinidis, L.1
Helwig, P.2
Strohm, P.C.3
Hirschmuller, A.4
Kron, P.5
Sudkamp, N.P.6
-
9
-
-
79952447026
-
Comparison of angle stable plate fixation approaches for distal radius fractures
-
COI: 1:STN:280:DC%2BC3Mnmt1Chsg%3D%3D, PID: 21144514
-
Matschke S, Wentzensen A, Ring D, Marent-Huber M, Audige L, Jupiter JB (2011) Comparison of angle stable plate fixation approaches for distal radius fractures. Injury 42(4):385–392. doi:10.1016/j.injury.2010.10.010
-
(2011)
Injury
, vol.42
, Issue.4
, pp. 385-392
-
-
Matschke, S.1
Wentzensen, A.2
Ring, D.3
Marent-Huber, M.4
Audige, L.5
Jupiter, J.B.6
-
10
-
-
74449090635
-
Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes
-
PID: 19819447
-
Knight D, Hajducka C, Will E, McQueen M (2010) Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes. Injury 41(2):184–189. doi:10.1016/j.injury.2009.08.024
-
(2010)
Injury
, vol.41
, Issue.2
, pp. 184-189
-
-
Knight, D.1
Hajducka, C.2
Will, E.3
McQueen, M.4
-
11
-
-
79959834851
-
Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study
-
PID: 21712136
-
Yu YR, Makhni MC, Tabrizi S, Rozental TD, Mundanthanam G, Day CS (2011) Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 36(7):1135–1141. doi:10.1016/j.jhsa.2011.04.004
-
(2011)
J Hand Surg Am
, vol.36
, Issue.7
, pp. 1135-1141
-
-
Yu, Y.R.1
Makhni, M.C.2
Tabrizi, S.3
Rozental, T.D.4
Mundanthanam, G.5
Day, C.S.6
-
12
-
-
69249217666
-
Volar locking compression plating versus dorsal plating for fractures of the distal radius: a prospective, randomized study
-
COI: 1:STN:280:DC%2BD1MrmsFejtw%3D%3D, PID: 19597773
-
Zettl RP, Clauberg E, Nast-Kolb D, Ruchholtz S, Kuhne CA (2009) Volar locking compression plating versus dorsal plating for fractures of the distal radius: a prospective, randomized study. Unfallchirurg 112(8):712–718. doi:10.1007/s00113-008-1526-5
-
(2009)
Unfallchirurg
, vol.112
, Issue.8
, pp. 712-718
-
-
Zettl, R.P.1
Clauberg, E.2
Nast-Kolb, D.3
Ruchholtz, S.4
Kuhne, C.A.5
-
13
-
-
79958042558
-
Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures
-
PID: 21549526
-
Chou YC, Chen AC, Chen CY, Hsu YH, Wu CC (2011) Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures. J Hand Surg Am 36(6):974–981. doi:10.1016/j.jhsa.2011.02.024
-
(2011)
J Hand Surg Am
, vol.36
, Issue.6
, pp. 974-981
-
-
Chou, Y.C.1
Chen, A.C.2
Chen, C.Y.3
Hsu, Y.H.4
Wu, C.C.5
-
14
-
-
34247217264
-
Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures
-
COI: 1:STN:280:DC%2BD2s7pvVKkug%3D%3D, PID: 17402138
-
Arora R, Lutz M, Zimmermann R, Krappinger D, Gabl M, Pechlaner S (2007) Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures. Handchir Mikrochir Plast Chir 39(1):34–41. doi:10.1055/s-2007-964922
-
(2007)
Handchir Mikrochir Plast Chir
, vol.39
, Issue.1
, pp. 34-41
-
-
Arora, R.1
Lutz, M.2
Zimmermann, R.3
Krappinger, D.4
Gabl, M.5
Pechlaner, S.6
-
15
-
-
79955973814
-
Operative treatment of distal radial fractures with locking plate system-a prospective study
-
PID: 21369946
-
Kwan K, Lau TW, Leung F (2011) Operative treatment of distal radial fractures with locking plate system-a prospective study. Int Orthop 35(3):389–394. doi:10.1007/s00264-010-0974-z
-
(2011)
Int Orthop
, vol.35
, Issue.3
, pp. 389-394
-
-
Kwan, K.1
Lau, T.W.2
Leung, F.3
-
16
-
-
77952268925
-
Functional results and complications following locking palmar plating on the distal radius: a retrospective study
-
COI: 1:STN:280:DC%2BC3czht1alsA%3D%3D
-
Hakimi M, Jungbluth P, Windolf J, Wild M (2010) Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg Eur 35(4):283–288. doi:10.1177/1753193409339943
-
(2010)
J Hand Surg Eur
, vol.35
, Issue.4
, pp. 283-288
-
-
Hakimi, M.1
Jungbluth, P.2
Windolf, J.3
Wild, M.4
-
17
-
-
84889086967
-
Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events
-
PID: 23515129
-
Tarallo L, Mugnai R, Zambianchi F, Adani R, Catani F (2013) Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events. J Orthop Trauma 27(12):740–745. doi:10.1097/BOT.0b013e3182913fc5
-
(2013)
J Orthop Trauma
, vol.27
, Issue.12
, pp. 740-745
-
-
Tarallo, L.1
Mugnai, R.2
Zambianchi, F.3
Adani, R.4
Catani, F.5
-
18
-
-
84857794955
-
The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates
-
PID: 22305729
-
Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP (2012) The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. J Hand Surg Am 37(3):446–453. doi:10.1016/j.jhsa.2011.12.013
-
(2012)
J Hand Surg Am
, vol.37
, Issue.3
, pp. 446-453
-
-
Wall, L.B.1
Brodt, M.D.2
Silva, M.J.3
Boyer, M.I.4
Calfee, R.P.5
-
19
-
-
79959400463
-
Screw prominences related to palmar locking plating of distal radius
-
COI: 1:STN:280:DC%2BC3MrgtFWltg%3D%3D
-
Sugun TS, Karabay N, Gurbuz Y, Ozaksar K, Toros T, Kayalar M (2011) Screw prominences related to palmar locking plating of distal radius. J Hand Surg Eur 36(4):320–324. doi:10.1177/1753193410392869
-
(2011)
J Hand Surg Eur
, vol.36
, Issue.4
, pp. 320-324
-
-
Sugun, T.S.1
Karabay, N.2
Gurbuz, Y.3
Ozaksar, K.4
Toros, T.5
Kayalar, M.6
-
20
-
-
79955874759
-
Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating
-
Ozer K, Toker S (2011) Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y) 6(2):190–193. doi:10.1007/s11552-010-9316-2
-
(2011)
Hand (N Y)
, vol.6
, Issue.2
, pp. 190-193
-
-
Ozer, K.1
Toker, S.2
-
21
-
-
58649097975
-
Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series
-
PID: 19122079
-
Jupiter JB, Marent-Huber M (2009) Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am 91(1):55–65. doi:10.2106/jbjs.g.01498
-
(2009)
J Bone Joint Surg Am
, vol.91
, Issue.1
, pp. 55-65
-
-
Jupiter, J.B.1
Marent-Huber, M.2
-
22
-
-
78650758688
-
Fracture of the distal radius: risk factors for complications after locked volar plate fixation
-
PID: 21193123
-
Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D (2011) Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am 36(1):3–9. doi:10.1016/j.jhsa.2010.09.033
-
(2011)
J Hand Surg Am
, vol.36
, Issue.1
, pp. 3-9
-
-
Soong, M.1
van Leerdam, R.2
Guitton, T.G.3
Got, C.4
Katarincic, J.5
Ring, D.6
-
23
-
-
84890236476
-
Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature
-
PID: 23670492
-
Asadollahi S, Keith PP (2013) Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol 14(4):227–234. doi:10.1007/s10195-013-0245-z
-
(2013)
J Orthop Traumatol
, vol.14
, Issue.4
, pp. 227-234
-
-
Asadollahi, S.1
Keith, P.P.2
-
24
-
-
77952513156
-
Quality of life after volar plate fixation of articular fractures of the distal part of the radius
-
PID: 20439663
-
Gruber G, Zacherl M, Giessauf C, Glehr M, Fuerst F, Liebmann W, Gruber K, Bernhardt GA (2010) Quality of life after volar plate fixation of articular fractures of the distal part of the radius. J Bone Joint Surg Am 92(5):1170–1178. doi:10.2106/jbjs.i.00737
-
(2010)
J Bone Joint Surg Am
, vol.92
, Issue.5
, pp. 1170-1178
-
-
Gruber, G.1
Zacherl, M.2
Giessauf, C.3
Glehr, M.4
Fuerst, F.5
Liebmann, W.6
Gruber, K.7
Bernhardt, G.A.8
-
25
-
-
77956636455
-
Distal radial fractures in the elderly: operative compared with nonoperative treatment
-
COI: 1:STN:280:DC%2BC3cjis1Gisg%3D%3D, PID: 20686059
-
Egol KA, Walsh M, Romo-Cardoso S, Dorsky S, Paksima N (2010) Distal radial fractures in the elderly: operative compared with nonoperative treatment. J Bone Joint Surg Am 92(9):1851–1857. doi:10.2106/jbjs.i.00968
-
(2010)
J Bone Joint Surg Am
, vol.92
, Issue.9
, pp. 1851-1857
-
-
Egol, K.A.1
Walsh, M.2
Romo-Cardoso, S.3
Dorsky, S.4
Paksima, N.5
-
26
-
-
39049092008
-
Biomechanical evaluation of volar locking plates for distal radius fractures
-
Levin SM, Nelson CO, Botts JD, Teplitz GA, Kwon Y, Serra-Hsu F (2008) Biomechanical evaluation of volar locking plates for distal radius fractures. Hand (N Y) 3(1):55–60. doi:10.1007/s11552-007-9063-1
-
(2008)
Hand (N Y)
, vol.3
, Issue.1
, pp. 55-60
-
-
Levin, S.M.1
Nelson, C.O.2
Botts, J.D.3
Teplitz, G.A.4
Kwon, Y.5
Serra-Hsu, F.6
-
27
-
-
34250889457
-
Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study
-
PID: 17606058
-
McCall TA, Conrad B, Badman B, Wright T (2007) Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study. J Hand Surg Am 32(6):806–812. doi:10.1016/j.jhsa.2007.04.016
-
(2007)
J Hand Surg Am
, vol.32
, Issue.6
, pp. 806-812
-
-
McCall, T.A.1
Conrad, B.2
Badman, B.3
Wright, T.4
-
28
-
-
34250651062
-
Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
-
PID: 17145377
-
Blythe M, Stoffel K, Jarrett P, Kuster M (2006) Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers. J Hand Surg Am 31(10):1587–1593. doi:10.1016/j.jhsa.2006.09.011
-
(2006)
J Hand Surg Am
, vol.31
, Issue.10
, pp. 1587-1593
-
-
Blythe, M.1
Stoffel, K.2
Jarrett, P.3
Kuster, M.4
|