메뉴 건너뛰기




Volumn 9781461472452, Issue , 2014, Pages 55-82

A novel image-based approach for early detection of prostate cancer using DCE-MRI

Author keywords

[No Author keywords available]

Indexed keywords

DEFORMATION; DIAGNOSIS; DISEASES; GAUSSIAN DISTRIBUTION; HISTOLOGY; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; MARKOV PROCESSES; NEAREST NEIGHBOR SEARCH; UROLOGY;

EID: 84911903047     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/978-1-4614-7245-2_3     Document Type: Chapter
Times cited : (13)

References (42)
  • 2
    • 0346997972 scopus 로고    scopus 로고
    • Epidemiology of prostate cancer
    • Crawford ED (2003) Epidemiology of prostate cancer. Urology 62(6 Suppl 1):3-12
    • (2003) Urology , vol.62 , Issue.6 , pp. 3-12
    • Crawford, E.D.1
  • 3
    • 49049102974 scopus 로고    scopus 로고
    • Benefits and harms of prostatespecific antigen screening for prostate cancer: An evidence update for the U.S. preventive services task force
    • Lin K, Lipsitz R, Miller T, Janakiraman S, Force UPST (2008) Benefits and harms of prostatespecific antigen screening for prostate cancer: an evidence update for the U.S. preventive services task force. Ann Intern Med 149(3):192-199
    • (2008) Ann Intern Med , vol.149 , Issue.3 , pp. 192-199
    • Lin, K.1    Lipsitz, R.2    Miller, T.3    Janakiraman, S.4    Upst, F.5
  • 4
    • 78149377824 scopus 로고    scopus 로고
    • Prostate cancer around the world
    • Schroder FH (2010) Prostate cancer around the world. An overview. Urol Oncol 28 (6):663-667
    • (2010) An Overview. Urol Oncol , vol.28 , Issue.6 , pp. 663-667
    • Schroder, F.H.1
  • 6
    • 0037941623 scopus 로고    scopus 로고
    • Segmentation of prostate boundaries from ultrasound images using statistical shape model
    • Shen D, Zhan Y, Davatzikos C (2003) Segmentation of prostate boundaries from ultrasound images using statistical shape model. IEEE Trans Med Imaging 22(4):539-551
    • (2003) IEEE Trans Med Imaging , vol.22 , Issue.4 , pp. 539-551
    • Shen, D.1    Zhan, Y.2    Davatzikos, C.3
  • 8
    • 33746897618 scopus 로고    scopus 로고
    • Automated segmentation of 3D US prostate images using statistical texture-based matching method
    • Montreal, 16-18 Nov 2003
    • Zhan Y, Shen D (2003) Automated segmentation of 3D US prostate images using statistical texture-based matching method. In: Medical image computing and computer-Assisted intervention (MICCAI), vol 2878, Montreal, 16-18 Nov 2003, pp 688-696
    • (2003) Medical Image Computing and Computer-Assisted Intervention (MICCAI , vol.2878 , pp. 688-696
    • Zhan, Y.1    Shen, D.2
  • 9
    • 1642329942 scopus 로고    scopus 로고
    • A parametric shape modeling using deformable super ellipses for prostate segmentation
    • Gong L, Pathak SD, Haynor DR, Cho PS, Kim Y (2004) A parametric shape modeling using deformable super ellipses for prostate segmentation. IEEE Trans Med Imaging 23:340-349
    • (2004) IEEE Trans Med Imaging , vol.23 , pp. 340-349
    • Gong, L.1    Pathak, S.D.2    Haynor, D.R.3    Cho, P.S.4    Kim, Y.5
  • 11
    • 77957234029 scopus 로고    scopus 로고
    • The role of dynamic contrastenhanced MRI in cancer diagnosis and treatment
    • Trkbey B, Thomasson D, Pang Y, Bernardo M, Choyke P (2010) The role of dynamic contrastenhanced MRI in cancer diagnosis and treatment. Turk Soc Radiol 16:186-192
    • (2010) Turk Soc Radiol , vol.16 , pp. 186-192
    • Trkbey, B.1    Thomasson, D.2    Pang, Y.3    Bernardo, M.4    Choyke, P.5
  • 16
    • 77950577125 scopus 로고    scopus 로고
    • Automated segmentation of the prostate in 3D MRI images using a probabilistic atlas and a spatially constrained deformable model
    • Martin S, Daanenc V, Troccaz J (2010) Automated segmentation of the prostate in 3D MRI images using a probabilistic atlas and a spatially constrained deformable model. Med Phys 37:1579-1590
    • (2010) Med Phys , vol.37 , pp. 1579-1590
    • Martin, S.1    Daanenc, V.2    Troccaz, J.3
  • 18
    • 0036090461 scopus 로고    scopus 로고
    • Serial biopsy results in prostate cancer screening study
    • Roehl K, Antenor J, Catalona W (2002) Serial biopsy results in prostate cancer screening study. J Am Urol Assoc 167:2435-2439
    • (2002) J Am Urol Assoc , vol.167 , pp. 2435-2439
    • Roehl, K.1    Antenor, J.2    Catalona, W.3
  • 19
    • 0028232103 scopus 로고
    • Serial prostatic biopsies in men with persistently elevated serum prostate specific antigen values
    • Keetch D, Catalona W, Smith D (1994) Serial prostatic biopsies in men with persistently elevated serum prostate specific antigen values. J Am Urol Assoc 151:1571-1574
    • (1994) J Am Urol Assoc , vol.151 , pp. 1571-1574
    • Keetch, D.1    Catalona, W.2    Smith, D.3
  • 20
    • 0141631865 scopus 로고    scopus 로고
    • Detection of prostate cancer by integration of line-scan diffusion T2-mapping and T2-weighted magnetic resonance imaging; A multichannel statistical classifier
    • Chan I, Wells W, Mulkern RV, Haker S, Zhang J, Zou KH, Maier SE, Tempany CMC (2003) Detection of prostate cancer by integration of line-scan diffusion, T2-mapping and T2-weighted magnetic resonance imaging; a multichannel statistical classifier. Med Phys 30 (9):2390-2398
    • (2003) Med Phys , vol.30 , Issue.9 , pp. 2390-2398
    • Chan, I.1    Wells, W.2    Mulkern, R.V.3    Haker, S.4    Zhang, J.5    Zou, K.H.6    Maier, S.E.7    Cmc, T.8
  • 24
    • 2342483754 scopus 로고    scopus 로고
    • Recurrent prostate cancer after external beam radiotherapy: Value of contrastenhanced dynamic MRI in localizing intraprostatic tumor correlation with biopsy findings
    • Rouviere O, Valette O, Grivolat S, Colin-Pangaud C, Bouvier R, Chapelon J, Gelet A, Lyonnet D (2004) Recurrent prostate cancer after external beam radiotherapy: value of contrastenhanced dynamic MRI in localizing intraprostatic tumor correlation with biopsy findings. Urology 63:922-927
    • (2004) Urology , vol.63 , pp. 922-927
    • Rouviere, O.1    Valette, O.2    Grivolat, S.3    Colin-Pangaud, C.4    Bouvier, R.5    Chapelon, J.6    Gelet, A.7    Lyonnet, D.8
  • 25
    • 27644568160 scopus 로고    scopus 로고
    • Wash-in rate on the basis of dynamic contrast-enhanced MRI: Usefulness for prostate cancer detection and localization
    • Kim J, Hong S, Choi Y et al (2005) Wash-in rate on the basis of dynamic contrast-enhanced MRI: usefulness for prostate cancer detection and localization. J Magn Reson Imaging 22:639-646
    • (2005) J Magn Reson Imaging , vol.22 , pp. 639-646
    • Kim, J.1    Hong, S.2    Choi, Y.3
  • 27
    • 0141518359 scopus 로고    scopus 로고
    • Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging
    • Engelbrecht M, Huisman H, Laheij R et al (2003) Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imaging. Radiology 229:248-254
    • (2003) Radiology , vol.229 , pp. 248-254
    • Engelbrecht, M.1    Huisman, H.2    Laheij, R.3
  • 32
    • 48149107192 scopus 로고    scopus 로고
    • EM based approximation of empirical distributions with linear combinations of discrete Gaussians
    • San Antonio, 16-19 Sept 2007
    • El-Baz A, Gimelfarb G (2007) EM based approximation of empirical distributions with linear combinations of discrete Gaussians. In: Proceedings of IEEE international conference on image processing, vol 4. San Antonio, 16-19 Sept 2007, pp 373-376
    • (2007) Proceedings of IEEE International Conference on Image Processing , vol.4 , pp. 373-376
    • El-Baz, A.1    Gimelfarb, G.2
  • 35
    • 0031221119 scopus 로고
    • Alignment by maximization of mutual information
    • Viola P, Wells WM III (1995) Alignment by maximization of mutual information. Int J Comput Vis 24:137-154
    • (1995) Int J Comput Vis , vol.24 , pp. 137-154
    • Viola, P.1    Wells, W.M.2
  • 36
    • 0000013152 scopus 로고
    • On the statistical analysis of dirty pictures
    • Besag J (1986) On the statistical analysis of dirty pictures. J R Stat Soc B 48(3):259-302
    • (1986) J R Stat Soc B , vol.48 , Issue.3 , pp. 259-302
    • Besag, J.1
  • 37
    • 0034310510 scopus 로고    scopus 로고
    • Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
    • Studholme C, Constable RT, Duncan J (2000) Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model. IEEE Trans Med Imaging 19 (11):1115-1127
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.11 , pp. 1115-1127
    • Studholme, C.1    Constable, R.T.2    Duncan, J.3
  • 38
    • 7044239648 scopus 로고    scopus 로고
    • Geodesic estimation for large deformation anatomical shape averaging and interpolation
    • Avants BB, Gee JC (2004) Geodesic estimation for large deformation anatomical shape averaging and interpolation. Neuroimage 23(1):139-150
    • (2004) Neuroimage , vol.23 , Issue.1 , pp. 139-150
    • Avants, B.B.1    Gee, J.C.2
  • 39
    • 0027624429 scopus 로고
    • A generalized Gaussian image model for edge-preserving MAP estimation
    • Bouman CA, Sauer K (1993) A generalized Gaussian image model for edge-preserving MAP estimation. IEEE Trans Image Process 2(3):296-310
    • (1993) IEEE Trans Image Process , vol.2 , Issue.3 , pp. 296-310
    • Bouman, C.A.1    Sauer, K.2
  • 41
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • Dice R (1945) Measures of the amount of ecologic association between species. Ecol Soc Am 26(3):297-302
    • (1945) Ecol Soc Am , vol.26 , Issue.3 , pp. 297-302
    • Dice, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.