메뉴 건너뛰기




Volumn 65, Issue , 2015, Pages 453-462

Modeling and model predictive control of the BioPower combined heat and power (CHP) plant

Author keywords

Advanced control; Biomass; Combustion; Fuel quality; Moisture; MPC

Indexed keywords

BIOMASS; BOILERS; COGENERATION PLANTS; COMBUSTION; DECOMPOSITION; FUELS; MODEL PREDICTIVE CONTROL; MOISTURE; MOISTURE CONTROL; PREDICTIVE CONTROL SYSTEMS;

EID: 84910121287     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijepes.2014.10.043     Document Type: Article
Times cited : (20)

References (15)
  • 5
    • 13644276755 scopus 로고    scopus 로고
    • Application of model predictive control to advanced combustion control
    • Havlena V, Findejs J. Application of model predictive control to advanced combustion control. Control Eng Pract 2005;13(6):671-80.
    • (2005) Control Eng Pract , vol.13 , Issue.6 , pp. 671-680
    • Havlena, V.1    Findejs, J.2
  • 6
    • 0032182666 scopus 로고    scopus 로고
    • A local model networks based multivariable long-range predictive control strategy for thermal power plants
    • Prasad G, Swidenbank E, Hogg BW. A local model networks based multivariable long-range predictive control strategy for thermal power plants. Automatica 1998;34(10):1185-204.
    • (1998) Automatica , vol.34 , Issue.10 , pp. 1185-1204
    • Prasad, G.1    Swidenbank, E.2    Hogg, B.W.3
  • 7
    • 33847375541 scopus 로고    scopus 로고
    • Robust stabilization of nonlinear interconnected systems with application to an industrial utility boiler
    • Swarnakar A, Marquez HJ, Chen T. Robust stabilization of nonlinear interconnected systems with application to an industrial utility boiler. Control Eng Pract 2007;15(6):639-54.
    • (2007) Control Eng Pract , vol.15 , Issue.6 , pp. 639-654
    • Swarnakar, A.1    Marquez, H.J.2    Chen, T.3
  • 8
    • 77649237532 scopus 로고    scopus 로고
    • Modelling of grate combustion in a medium scale biomass furnace for control purposes
    • Bauer R, Grölles M, Brunner T, Dourdoumas N, Obernberger I. Modelling of grate combustion in a medium scale biomass furnace for control purposes. Biomass Bioenergy 2010;34(4):417-27.
    • (2010) Biomass Bioenergy , vol.34 , Issue.4 , pp. 417-427
    • Bauer, R.1    Grölles, M.2    Brunner, T.3    Dourdoumas, N.4    Obernberger, I.5
  • 9
    • 22644441065 scopus 로고    scopus 로고
    • Effect of fuel properties on biomass combustion. Part II. Modelling approach-identification of the controlling factors
    • Yang YB, Ryu C, Khor A, Yates NE, Sharifi VN, Swithenbank J. Effect of fuel properties on biomass combustion. Part II. Modelling approach-identification of the controlling factors. Fuel 2005;84(16):2116-30.
    • (2005) Fuel , vol.84 , Issue.16 , pp. 2116-2130
    • Yang, Y.B.1    Ryu, C.2    Khor, A.3    Yates, N.E.4    Sharifi, V.N.5    Swithenbank, J.6
  • 10
    • 83955165245 scopus 로고    scopus 로고
    • Dynamic modeling of combustion in a BioGrate furnace: The effect of operation paramets on biomass firing
    • Boriouchkine A, Zakharov A, Jämsä-Jounela S-L. Dynamic modeling of combustion in a BioGrate furnace: the effect of operation paramets on biomass firing. Chem Eng Sci 2012;69(1):669-78.
    • (2012) Chem Eng Sci , vol.69 , Issue.1 , pp. 669-678
    • Boriouchkine, A.1    Zakharov, A.2    Jämsä-Jounela, S.-L.3
  • 11
    • 84860564864 scopus 로고    scopus 로고
    • Fuel-quality soft sensor using the dynamic superheater model for control strategy improvement of the BioPower 5 CHP plant
    • Kortela J, Jämsä-Jounela S-L. Fuel-quality soft sensor using the dynamic superheater model for control strategy improvement of the BioPower 5 CHP plant. Int J Electr Power Energy Syst 2012;42(1):38-48.
    • (2012) Int J Electr Power Energy Syst , vol.42 , Issue.1 , pp. 38-48
    • Kortela, J.1    Jämsä-Jounela, S.-L.2
  • 13
    • 0037328973 scopus 로고    scopus 로고
    • Disturbance models for offset-free mode-predictive control
    • Pannocchia G, Rawlings JB. Disturbance models for offset-free mode-predictive control. AIChE 2003;49(2):426-7.
    • (2003) AIChE , vol.49 , Issue.2 , pp. 426-427
    • Pannocchia, G.1    Rawlings, J.B.2
  • 14
    • 0342298451 scopus 로고    scopus 로고
    • Drum-boiler dynamics
    • A˚ström KJ, Bell RD. Drum-boiler dynamics. Automatica 2000;36(3):363-78.
    • (2000) Automatica , vol.36 , Issue.3 , pp. 363-378
    • A˚ström, K.J.1    Bell, R.D.2
  • 15
    • 84872648245 scopus 로고    scopus 로고
    • Fuel moisture soft-sensor and its validation for the industrial BioPower 5 CHP plant
    • Kortela J, Jämsä-Jounela S-L. Fuel moisture soft-sensor and its validation for the industrial BioPower 5 CHP plant. Applied Energy 2013;105:66-74.
    • (2013) Applied Energy , vol.105 , pp. 66-74
    • Kortela, J.1    Jämsä-Jounela, S.-L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.