메뉴 건너뛰기




Volumn 15, Issue 1, 2015, Pages 14-18

Plastic optical fiber sensor for noninvasive arterial pulse waveform monitoring

Author keywords

Biomedical transducer; Cardiology; Hypertension.; Index Terms Optical fiber sensors; Plastic optical fiber

Indexed keywords

BIOSENSORS; CARDIOLOGY; COMPOSITE STRUCTURES; FIBER OPTIC SENSORS; FIBERS; FUNCTIONAL POLYMERS; PLASTICS; SIGNAL PROCESSING;

EID: 84910088928     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2014.2336594     Document Type: Article
Times cited : (34)

References (21)
  • 2
    • 44649116353 scopus 로고    scopus 로고
    • The influence of wave reflection on left ventricular hypertrophy in hypertensive patients is modified by age and gender
    • Y. Matsui et al., "The influence of wave reflection on left ventricular hypertrophy in hypertensive patients is modified by age and gender," Hypertension Res., vol. 31, no. 4, pp. 649-656, 2008.
    • (2008) Hypertension Res. , vol.31 , Issue.4 , pp. 649-656
    • Matsui, Y.1
  • 3
    • 0029955453 scopus 로고    scopus 로고
    • Vascular hypertrophy is an early finding in essential hypertension and is related to arterial pressure waveform contour
    • F. D. Tice et al., "Vascular hypertrophy is an early finding in essential hypertension and is related to arterial pressure waveform contour," Amer. Heart J., vol. 132, no. 3, pp. 621-627, 1996.
    • (1996) Amer. Heart J. , vol.132 , Issue.3 , pp. 621-627
    • Tice, F.D.1
  • 4
    • 84869087378 scopus 로고    scopus 로고
    • Arterial wave reflections and incident cardiovascular events and heart failure: MESA (multiethnic study of atherosclerosis)
    • J. A. Chirinos et al., "Arterial wave reflections and incident cardiovascular events and heart failure: MESA (multiethnic study of atherosclerosis)," J. Amer. College Cardiol., vol. 60, no. 21, pp. 2170-2177, 2012.
    • (2012) J. Amer. College Cardiol. , vol.60 , Issue.21 , pp. 2170-2177
    • Chirinos, J.A.1
  • 5
    • 33644853054 scopus 로고    scopus 로고
    • Arterial stiffness and risk of coronary heart disease and stroke the Rotterdam study
    • F. Mattace-Raso et al., "Arterial stiffness and risk of coronary heart disease and stroke the Rotterdam study," Circulation, vol. 113, no. 5, pp. 657-663, 2006.
    • (2006) Circulation , vol.113 , Issue.5 , pp. 657-663
    • Mattace-Raso, F.1
  • 6
    • 1642535532 scopus 로고    scopus 로고
    • Arterial stiffness, wave reflections, and the risk of coronary artery disease
    • T. Weber et al., "Arterial stiffness, wave reflections, and the risk of coronary artery disease," Circulation, vo. 109, no. 2, pp. 184-189, 2004.
    • (2004) Circulation , vol.109 , Issue.2 , pp. 184-189
    • Weber, T.1
  • 8
    • 84884188797 scopus 로고    scopus 로고
    • Arterial applanation tonometry: Technical aspects relevant for its daily clinical use
    • P. Salvi, M. E. Safar, and G. Parati, "Arterial applanation tonometry: Technical aspects relevant for its daily clinical use," J. Hypertension, vol. 31, no. 3, pp. 469-471, 2013.
    • (2013) J. Hypertension , vol.31 , Issue.3 , pp. 469-471
    • Salvi, P.1    Safar, M.E.2    Parati, G.3
  • 9
    • 0030970060 scopus 로고    scopus 로고
    • Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure-Validation of generalized transfer function
    • C. Chen et al., "Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure-Validation of generalized transfer function," Circulation, vol. 95, no. 7, pp. 1827-1836, 1997.
    • (1997) Circulation , vol.95 , Issue.7 , pp. 1827-1836
    • Chen, C.1
  • 10
    • 84870257287 scopus 로고    scopus 로고
    • Clinical assessment of central blood pressure
    • H. Miyashita, "Clinical assessment of central blood pressure," Current Hypertension Rev., vol. 8, no. 2, pp. 80-90, 2012.
    • (2012) Current Hypertension Rev. , vol.8 , Issue.2 , pp. 80-90
    • Miyashita, H.1
  • 13
    • 84879910536 scopus 로고    scopus 로고
    • Review of fiber-optic pressure sensors for biomedical and biomechanical applications
    • P. Roriz, O. Frazão, A. Lobo-Ribeiro, J. L. Santos, and J. A. Simões, "Review of fiber-optic pressure sensors for biomedical and biomechanical applications," J. Biomed. Opt., vol. 18, no. 5, p. 050903, 2013.
    • (2013) J. Biomed. Opt. , vol.18 , Issue.5 , pp. 050903
    • Roriz, P.1    Frazão, O.2    Lobo-Ribeiro, A.3    Santos, J.L.4    Simões, J.A.5
  • 14
    • 78650238879 scopus 로고    scopus 로고
    • Fibre optic sensor for non-invasive monitoring of blood pressure during MRI scanning
    • T. S. Myllylä et al., "Fibre optic sensor for non-invasive monitoring of blood pressure during MRI scanning," J. Biophoton., vol. 4, nos. 1-2, pp. 98-107, 2011.
    • (2011) J. Biophoton. , vol.4 , Issue.1-2 , pp. 98-107
    • Myllylä, T.S.1
  • 15
    • 84878226835 scopus 로고    scopus 로고
    • Feasibility studies of Bragg probe for noninvasive carotid pulse waveform assessment
    • C. Leitão, L. Bilro, N. Alberto, P. Antunes, and H. Lima, "Feasibility studies of Bragg probe for noninvasive carotid pulse waveform assessment," J. Biomed. Opt., vol. 18, no. 1, p. 017006, 2013.
    • (2013) J. Biomed. Opt. , vol.18 , Issue.1 , pp. 017006
    • Leitão, C.1    Bilro, L.2    Alberto, N.3    Antunes, P.4    Lima, H.5
  • 16
    • 84867025693 scopus 로고    scopus 로고
    • Optical sensors based on plastic fibers
    • L. Bilro, N. Alberto, J. L. Pinto, and R. Nogueira, "Optical sensors based on plastic fibers," Sensors, vol. 12, no. 9, pp. 12184-12207, 2012.
    • (2012) Sensors , vol.12 , Issue.9 , pp. 12184-12207
    • Bilro, L.1    Alberto, N.2    Pinto, J.L.3    Nogueira, R.4
  • 17
    • 84876035612 scopus 로고    scopus 로고
    • Intensity-encoded polymer optical fiber accelerometer
    • May
    • P. F. C. Antunes, H. Varum, and P. S. André, "Intensity-encoded polymer optical fiber accelerometer," IEEE Sensors J., vol. 13, no. 5, pp. 1716-1720, May 2013.
    • (2013) IEEE Sensors J. , vol.13 , Issue.5 , pp. 1716-1720
    • Antunes, P.F.C.1    Varum, H.2    André, P.S.3
  • 19
    • 35848946593 scopus 로고    scopus 로고
    • Indices of cardiovascular function derived from peripheral pulse wave analysis using radial applanation tonometry: A measurement repeatability study
    • M. Crilly, C. Coch, M. Bruce, H. Clark, and D. Williams, "Indices of cardiovascular function derived from peripheral pulse wave analysis using radial applanation tonometry: A measurement repeatability study," Vascular Med., vol. 12, no. 3, pp. 189-197, 2007.
    • (2007) Vascular Med. , vol.12 , Issue.3 , pp. 189-197
    • Crilly, M.1    Coch, C.2    Bruce, M.3    Clark, H.4    Williams, D.5
  • 20
    • 0015256392 scopus 로고
    • Experimental subendocardial ischemia in dogs with normal coronary arteries
    • G. D. Buckberg, D. E. Fixler, J. P. Archie, and J. Hoffman, "Experimental subendocardial ischemia in dogs with normal coronary arteries," Circulation Res., vol. 30, no. 1, pp. 67-81, 1972.
    • (1972) Circulation Res. , vol.30 , Issue.1 , pp. 67-81
    • Buckberg, G.D.1    Fixler, D.E.2    Archie, J.P.3    Hoffman, J.4
  • 21
    • 0018826031 scopus 로고
    • Aortic input impedance in normal man: Relationship to pressure wave forms
    • J. Murgo, N. Westerhof, J. Giolma, and S. Altobelli, "Aortic input impedance in normal man: Relationship to pressure wave forms," Circulation, vol. 62, no. 1, pp. 105-116, 1980.
    • (1980) Circulation , vol.62 , Issue.1 , pp. 105-116
    • Murgo, J.1    Westerhof, N.2    Giolma, J.3    Altobelli, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.