메뉴 건너뛰기




Volumn 439, Issue , 2015, Pages 195-201

Validation and evaluation of eight commercially available point of care CRP methods

Author keywords

C reactive protein; General practice; Point of care

Indexed keywords

C REACTIVE PROTEIN; C-REACTIVE PROTEIN;

EID: 84909979505     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2014.10.028     Document Type: Article
Times cited : (47)

References (11)
  • 1
    • 84884358535 scopus 로고    scopus 로고
    • Feasibility of using C-reactive protein for point-of-care testing
    • Joshi A., Perin D.P., Gehle A., Nsiah-Kumi P.A. Feasibility of using C-reactive protein for point-of-care testing. Technol Health Care 2013, 21:233-240.
    • (2013) Technol Health Care , vol.21 , pp. 233-240
    • Joshi, A.1    Perin, D.P.2    Gehle, A.3    Nsiah-Kumi, P.A.4
  • 2
    • 77950928463 scopus 로고    scopus 로고
    • C-reactive protein point-of-care testing for lower respiratory tract infections: a qualitative evaluation of experiences by GPs
    • Cals J.W., Chappin F.H., Hopstaken R.M., van Leeuwen M.E., Hood K., Butler C.C., et al. C-reactive protein point-of-care testing for lower respiratory tract infections: a qualitative evaluation of experiences by GPs. Fam Pract 2010, 27:212-218.
    • (2010) Fam Pract , vol.27 , pp. 212-218
    • Cals, J.W.1    Chappin, F.H.2    Hopstaken, R.M.3    van Leeuwen, M.E.4    Hood, K.5    Butler, C.C.6
  • 4
    • 20344402528 scopus 로고    scopus 로고
    • Evaluation of fluorescence hs-CRP immunoassay for point-of-care testing
    • Oh S.W., Moon J.D., Park S.Y., Jang H.J., Kim J.H., Nahm K.B., et al. Evaluation of fluorescence hs-CRP immunoassay for point-of-care testing. Clin Chim Acta 2005, 356:172-177.
    • (2005) Clin Chim Acta , vol.356 , pp. 172-177
    • Oh, S.W.1    Moon, J.D.2    Park, S.Y.3    Jang, H.J.4    Kim, J.H.5    Nahm, K.B.6
  • 6
    • 78349290459 scopus 로고    scopus 로고
    • Laboratory evaluation of a new lateral-flow-based point-of-care rapid test for assessment of chronic systemic inflammation
    • Siebenhaar R., Mushholt P.B., Forst T., Weber M.M., Maurer R., Pfützner A. Laboratory evaluation of a new lateral-flow-based point-of-care rapid test for assessment of chronic systemic inflammation. J Diabetes Sci Technol 2010, 4:717-722.
    • (2010) J Diabetes Sci Technol , vol.4 , pp. 717-722
    • Siebenhaar, R.1    Mushholt, P.B.2    Forst, T.3    Weber, M.M.4    Maurer, R.5    Pfützner, A.6
  • 8
    • 84903521851 scopus 로고    scopus 로고
    • Comparison of novel and familiar commercial kits for detection of C-reactive protein levels
    • Ciftci I.H., Koroglu M., Karakece E. Comparison of novel and familiar commercial kits for detection of C-reactive protein levels. World J Microbiol Biotechnol 2014, 30:2295-2298.
    • (2014) World J Microbiol Biotechnol , vol.30 , pp. 2295-2298
    • Ciftci, I.H.1    Koroglu, M.2    Karakece, E.3
  • 9
    • 84897104724 scopus 로고    scopus 로고
    • Development of a new point-of-care testing system for measuring white blood cell and C-reactive protein levels in whole blood samples
    • Kotani K., Minami T., Abe T., Sato J., Taniguchi N., Yamada T. Development of a new point-of-care testing system for measuring white blood cell and C-reactive protein levels in whole blood samples. Clin Chim Acta 2014, 433:145-149.
    • (2014) Clin Chim Acta , vol.433 , pp. 145-149
    • Kotani, K.1    Minami, T.2    Abe, T.3    Sato, J.4    Taniguchi, N.5    Yamada, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.