메뉴 건너뛰기




Volumn 138, Issue , 2014, Pages 203-214

Treatment of Cr(VI) present in plating wastewater using a Cu/Fe galvanic reactor

Author keywords

Chloride removal; Cr(VI) reduction; H2 N2 production; Nitrate reduction; Sulfate reduction

Indexed keywords

CATHODES; CHLORINE COMPOUNDS; CHROMIUM METALLOGRAPHY; COPPER; IONS; IRON; IRON METALLOGRAPHY; NITRATES; REDUCTION; SULFUR COMPOUNDS; WASTEWATER RECLAMATION; WASTEWATER TREATMENT;

EID: 84908491065     PISSN: 00162361     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.fuel.2014.07.101     Document Type: Conference Paper
Times cited : (12)

References (48)
  • 3
    • 0037056555 scopus 로고    scopus 로고
    • Performance of an ultra-low-pressure reverse osmosis membrane (ULPROM) for separating heavy metal: Effects of interference parameters
    • Ozaki H, Sharma K, Saktaywin W. Performance of an ultra-low-pressure reverse osmosis membrane (ULPROM) for separating heavy metal: effects of interference parameters. Desalination 2002;144(1):287-94.
    • (2002) Desalination , vol.144 , Issue.1 , pp. 287-294
    • Ozaki, H.1    Sharma, K.2    Saktaywin, W.3
  • 4
    • 77950689267 scopus 로고    scopus 로고
    • Polymer-enhanced ultrafiltration process for heavy metals removal from industrial wastewater
    • Barakat MA, Schmidt E. Polymer-enhanced ultrafiltration process for heavy metals removal from industrial wastewater. Desalination 2010;256(1):90-3.
    • (2010) Desalination , vol.256 , Issue.1 , pp. 90-93
    • Barakat, M.A.1    Schmidt, E.2
  • 5
    • 0034984987 scopus 로고    scopus 로고
    • Treatment of chromium plating process effluents with ion exchange resins
    • Tenorio JAS, Espinosa DCR. Treatment of chromium plating process effluents with ion exchange resins. Waste Manage 2001;21(7):637-42.
    • (2001) Waste Manage , vol.21 , Issue.7 , pp. 637-642
    • Tenorio, J.A.S.1    Espinosa, D.C.R.2
  • 6
    • 84861462050 scopus 로고    scopus 로고
    • A review of chemical, electrochemical and biological methods for aqueous Cr (VI) reduction
    • Barrera-Díaz CE, Lugo-Lugo V, Bilyeu B. A review of chemical, electrochemical and biological methods for aqueous Cr (VI) reduction. J Hazard Mater 2012;223:1-12.
    • (2012) J Hazard Mater , vol.223 , pp. 1-12
    • Barrera-Díaz, C.E.1    Lugo-Lugo, V.2    Bilyeu, B.3
  • 7
    • 67649863765 scopus 로고    scopus 로고
    • Effect of pH and chloride concentration on the removal of hexavalent chromium in a batch electrocoagulation reactor
    • Arroyo MG, Pérez-Herranz V, Montanes MT, García-Antón J, Guiñón JL. Effect of pH and chloride concentration on the removal of hexavalent chromium in a batch electrocoagulation reactor. J Hazard Mater 2009;169(1):1127-33.
    • (2009) J Hazard Mater , vol.169 , Issue.1 , pp. 1127-1133
    • Arroyo, M.G.1    Pérez-Herranz, V.2    Montanes, M.T.3    García-Antón, J.4    Guiñón, J.L.5
  • 8
    • 42249099193 scopus 로고    scopus 로고
    • Removal of Cr (VI) from model wastewaters by electrocoagulation with Fe electrodes
    • Heidmann I, Calmano W. Removal of Cr (VI) from model wastewaters by electrocoagulation with Fe electrodes. Sep Purif Technol 2008;61(1):15-21.
    • (2008) Sep Purif Technol , vol.61 , Issue.1 , pp. 15-21
    • Heidmann, I.1    Calmano, W.2
  • 9
    • 57649199808 scopus 로고    scopus 로고
    • The optimization of Cr (VI) reduction and removal by electrocoagulation using response surface methodology
    • Ölmez T. The optimization of Cr (VI) reduction and removal by electrocoagulation using response surface methodology. J Hazard Mater 2009;162(2):1371-8.
    • (2009) J Hazard Mater , vol.162 , Issue.2 , pp. 1371-1378
    • Ölmez, T.1
  • 10
    • 71749120352 scopus 로고    scopus 로고
    • Electrocoagulation removal of Cr (VI) from simulated wastewater using response surface methodology
    • Bhatti MS, Reddy AS, Thukral AK. Electrocoagulation removal of Cr (VI) from simulated wastewater using response surface methodology. J Hazard Mater 2009;172(2):839-46.
    • (2009) J Hazard Mater , vol.172 , Issue.2 , pp. 839-846
    • Bhatti, M.S.1    Reddy, A.S.2    Thukral, A.K.3
  • 11
    • 34548089903 scopus 로고    scopus 로고
    • Removal of Cr (VI) from aqueous solution: Electrocoagulation vs chemical coagulation
    • Golder AK, Chanda AK, Samanta AN, Ray S. Removal of Cr (VI) from aqueous solution: electrocoagulation vs chemical coagulation. Sep Sci Technol 2007;42(10):2177-93.
    • (2007) Sep Sci Technol , vol.42 , Issue.10 , pp. 2177-2193
    • Golder, A.K.1    Chanda, A.K.2    Samanta, A.N.3    Ray, S.4
  • 12
    • 70349230838 scopus 로고    scopus 로고
    • Removal of Cr (VI) from polluted solutions by electrocoagulation: Modeling of experimental results using artificial neural network
    • Aber S, Amani-Ghadim AR, Mirzajani V. Removal of Cr (VI) from polluted solutions by electrocoagulation: modeling of experimental results using artificial neural network. J Hazard Mater 2009;171(1):484-90.
    • (2009) J Hazard Mater , vol.171 , Issue.1 , pp. 484-490
    • Aber, S.1    Amani-Ghadim, A.R.2    Mirzajani, V.3
  • 13
    • 67649962206 scopus 로고    scopus 로고
    • Electrochemical removal of Cr (VI) from aqueous media using iron and aluminum as electrode materials: Towards a better understanding of the involved phenomena
    • Mouedhen G, Feki M, De Petris-Wery M, Ayedi HF. Electrochemical removal of Cr (VI) from aqueous media using iron and aluminum as electrode materials: towards a better understanding of the involved phenomena. J Hazard Mater 2009;168(2):983-91.
    • (2009) J Hazard Mater , vol.168 , Issue.2 , pp. 983-991
    • Mouedhen, G.1    Feki, M.2    De Petris-Wery, M.3    Ayedi, H.F.4
  • 15
    • 59849099589 scopus 로고    scopus 로고
    • Removal of Cr (VI) from wastewaters at semi-industrial electrochemical reactors with rotating ring electrodes
    • Rodríguez RMG, Mendoza V, Puebla H, Martínez DSA. Removal of Cr (VI) from wastewaters at semi-industrial electrochemical reactors with rotating ring electrodes. J Hazard Mater 2009;163(2):1221-9.
    • (2009) J Hazard Mater , vol.163 , Issue.2 , pp. 1221-1229
    • Rodríguez, R.M.G.1    Mendoza, V.2    Puebla, H.3    Martínez, D.S.A.4
  • 16
  • 17
    • 15244347898 scopus 로고    scopus 로고
    • Electroreduction of Cr (VI) to Cr (III) on reticulated vitreous carbon electrodes in a parallel-plate reactor with recirculation
    • Rodriguez-Valadez F, Ortiz-Éxiga C, Ibanez JG, Alatorre-Ordaz A, Gutierrez-Granados S. Electroreduction of Cr (VI) to Cr (III) on reticulated vitreous carbon electrodes in a parallel-plate reactor with recirculation. Environ Sci Technol 2005;39(6):1875-9.
    • (2005) Environ Sci Technol , vol.39 , Issue.6 , pp. 1875-1879
    • Rodriguez-Valadez, F.1    Ortiz-Éxiga, C.2    Ibanez, J.G.3    Alatorre-Ordaz, A.4    Gutierrez-Granados, S.5
  • 18
    • 11144311104 scopus 로고    scopus 로고
    • Chromium (VI) reduction using conducting polymer films
    • Ruotolo LAM, Gubulin JC. Chromium (VI) reduction using conducting polymer films. React Funct Polym 2005;62(2):141-51.
    • (2005) React Funct Polym , vol.62 , Issue.2 , pp. 141-151
    • Ruotolo, L.A.M.1    Gubulin, J.C.2
  • 19
    • 33646096465 scopus 로고    scopus 로고
    • Electrochemical treatment of effluents containing Cr (VI). Influence of pH and current on the kinetic
    • Ruotolo LAM, Santos-Júnior DS, Gubulin JC. Electrochemical treatment of effluents containing Cr (VI). Influence of pH and current on the kinetic. Water Res 2006;40(8):1555-60.
    • (2006) Water Res , vol.40 , Issue.8 , pp. 1555-1560
    • Ruotolo, L.A.M.1    Santos-Júnior, D.S.2    Gubulin, J.C.3
  • 20
    • 63149088770 scopus 로고    scopus 로고
    • Optimization of Cr (VI) electroreduction from synthetic industrial wastewater using reticulated vitreous carbon electrodes modified with conducting polymers
    • Ruotolo LAM, Gubulin JC. Optimization of Cr (VI) electroreduction from synthetic industrial wastewater using reticulated vitreous carbon electrodes modified with conducting polymers. Chem Eng J 2009;149(1):334-9.
    • (2009) Chem Eng J , vol.149 , Issue.1 , pp. 334-339
    • Ruotolo, L.A.M.1    Gubulin, J.C.2
  • 23
    • 0030129366 scopus 로고    scopus 로고
    • Biological activated carbon treatment of effluent water from wastewater treatment processes of plating industries
    • Suzuki Y, Mochidzuki K, Takeuchi Y, Yagishita Y, Fukuda T, Amakusa H, et al. Biological activated carbon treatment of effluent water from wastewater treatment processes of plating industries. Sep Technol 1996;6(2):147-53.
    • (1996) Sep Technol , vol.6 , Issue.2 , pp. 147-153
    • Suzuki, Y.1    Mochidzuki, K.2    Takeuchi, Y.3    Yagishita, Y.4    Fukuda, T.5    Amakusa, H.6
  • 24
    • 21244454752 scopus 로고    scopus 로고
    • Studies on recovery of hexavalent chromium from plating wastewater by supported liquid membrane using tri-n-butyl phosphate as carrier
    • Venkateswaran P, Palanivelu K. Studies on recovery of hexavalent chromium from plating wastewater by supported liquid membrane using tri-n-butyl phosphate as carrier. Hydrometallurgy 2005;78(1):107-15.
    • (2005) Hydrometallurgy , vol.78 , Issue.1 , pp. 107-115
    • Venkateswaran, P.1    Palanivelu, K.2
  • 25
    • 38349011563 scopus 로고    scopus 로고
    • Characteristics and application of multiple membrane process in plating wastewater reutilization
    • Zuo W, Zhang G, Meng Q, Zhang H. Characteristics and application of multiple membrane process in plating wastewater reutilization. Desalination 2008;222(1):187-96.
    • (2008) Desalination , vol.222 , Issue.1 , pp. 187-196
    • Zuo, W.1    Zhang, G.2    Meng, Q.3    Zhang, H.4
  • 26
    • 0003425384 scopus 로고    scopus 로고
    • WEF (American Public Health Association, American Water Works Association, and Water Environment Federation). Washington DC: The Associations and Federation
    • Standard methods for the examination of water and wastewater, APHA, AWWA. WEF (American Public Health Association, American Water Works Association, and Water Environment Federation). Washington DC: The Associations and Federation; 1998.
    • (1998) Standard Methods for the Examination of Water and Wastewater, APHA, AWWA
  • 28
    • 84908492398 scopus 로고    scopus 로고
    • China: HANWEI ELETRONICS Co., Ltd. [cited 2014 February 12]
    • Datasheet, MQ-8 gas sensor [Internet]. China: HANWEI ELETRONICS Co., Ltd. [cited 2014 February 12]. 〈http://dlnmh9ip6v2uc.cloudfront.net/datasheets/Sensors/Biometric/MQ-8.pdf〉.
    • Datasheet, MQ-8 Gas Sensor [Internet]
  • 29
    • 33646827480 scopus 로고    scopus 로고
    • Kinetics of hexavalent chromium reduction by scrap iron
    • Gheju M, Iovi A. Kinetics of hexavalent chromium reduction by scrap iron. J Hazard Mater 2006;135(1):66-73.
    • (2006) J Hazard Mater , vol.135 , Issue.1 , pp. 66-73
    • Gheju, M.1    Iovi, A.2
  • 30
    • 84872363382 scopus 로고    scopus 로고
    • Integration of ion exchange and electrodeionization as a new approach for the continuous treatment of hexavalent chromium wastewater
    • Alvarado L, Torres IR, Chen A. Integration of ion exchange and electrodeionization as a new approach for the continuous treatment of hexavalent chromium wastewater. Sep Purif Technol 2013;105:55-62.
    • (2013) Sep Purif Technol , vol.105 , pp. 55-62
    • Alvarado, L.1    Torres, I.R.2    Chen, A.3
  • 31
    • 84856216562 scopus 로고    scopus 로고
    • Chromium (VI) and zinc (II) waste water co-treatment by forming layered double hydroxides: Mechanism discussion via two different processes and application in real plating water
    • Zhang J, Li Y, Zhou J, Chen D, Qian G. Chromium (VI) and zinc (II) waste water co-treatment by forming layered double hydroxides: mechanism discussion via two different processes and application in real plating water. J Hazard Mater 2012;205:111-7.
    • (2012) J Hazard Mater , vol.205 , pp. 111-117
    • Zhang, J.1    Li, Y.2    Zhou, J.3    Chen, D.4    Qian, G.5
  • 33
    • 40949121456 scopus 로고    scopus 로고
    • Hexavalent chromium reduction with scrap iron in continuous-flow system: Part 1: Effect of feed solution pH
    • Gheju M, Iovi A, Balcu I. Hexavalent chromium reduction with scrap iron in continuous-flow system: Part 1: effect of feed solution pH. J Hazard Mater 2008;153:655-62.
    • (2008) J Hazard Mater , vol.153 , pp. 655-662
    • Gheju, M.1    Iovi, A.2    Balcu, I.3
  • 35
    • 0002969225 scopus 로고    scopus 로고
    • Microbial reduction of chromate
    • Lovley DR, editor. Washington DC: ASM Press
    • Wang YT. Microbial reduction of chromate. In: Lovley DR, editor. Environmental microbe-metal interaction. Washington DC: ASM Press; 2000. p. 225-35.
    • (2000) Environmental Microbe-metal Interaction , pp. 225-235
    • Wang, Y.T.1
  • 37
    • 2942650492 scopus 로고    scopus 로고
    • Effects of low pH on nitrate reduction by iron powder
    • Huang YH, Zhang TC. Effects of low pH on nitrate reduction by iron powder. Water Res 2004;38(11):2631-42.
    • (2004) Water Res , vol.38 , Issue.11 , pp. 2631-2642
    • Huang, Y.H.1    Zhang, T.C.2
  • 38
    • 0016972080 scopus 로고
    • Chemical reduction of nitrate by ferrous iron
    • Buresh RJ, Moraghan JT. Chemical reduction of nitrate by ferrous iron. J Environ Qual 1976;5(3):320-5.
    • (1976) J Environ Qual , vol.5 , Issue.3 , pp. 320-325
    • Buresh, R.J.1    Moraghan, J.T.2
  • 39
    • 84878870251 scopus 로고    scopus 로고
    • Three-dimensional electrochemical process for wastewater treatment: A general review
    • Zhang C, Jiang Y, Li Y, Hu Z, Zhou L, Zhou M. Three-dimensional electrochemical process for wastewater treatment: a general review. Chem Eng J 2013;228:455-67.
    • (2013) Chem Eng J , vol.228 , pp. 455-467
    • Zhang, C.1    Jiang, Y.2    Li, Y.3    Hu, Z.4    Zhou, L.5    Zhou, M.6
  • 40
    • 84908482743 scopus 로고    scopus 로고
    • A review of nitrate reduction using inorganic materials
    • Zhu I, Getting T. A review of nitrate reduction using inorganic materials. Environ Technol Rev 2012;1(1):46-58.
    • (2012) Environ Technol Rev , vol.1 , Issue.1 , pp. 46-58
    • Zhu, I.1    Getting, T.2
  • 41
    • 0032179206 scopus 로고    scopus 로고
    • Thermo-electrochemical reduction of sulfate to sulfide using a graphite cathode
    • Bilal BA, Tributsch H. Thermo-electrochemical reduction of sulfate to sulfide using a graphite cathode. J Electrochim 1998;28(10):1073-81.
    • (1998) J Electrochim , vol.28 , Issue.10 , pp. 1073-1081
    • Bilal, B.A.1    Tributsch, H.2
  • 42
    • 0242318194 scopus 로고    scopus 로고
    • Electrochemical corrosion of unalloyed copper in chloride media a critical review
    • Kear G, Barker BD, Walsh FC. Electrochemical corrosion of unalloyed copper in chloride media a critical review. Corros Sci 2004;46(1):109-35.
    • (2004) Corros Sci , vol.46 , Issue.1 , pp. 109-135
    • Kear, G.1    Barker, B.D.2    Walsh, F.C.3
  • 43
    • 0021539601 scopus 로고
    • Influence of chloride on the formation of iron oxides from Fe(II) chloride. II. Effect of [Cl] on the formation of lepidocrocite and its crystallinity
    • Taylor RM. Influence of chloride on the formation of iron oxides from Fe(II) chloride. II. Effect of [Cl] on the formation of lepidocrocite and its crystallinity. Clays Clay Miner 1984;32(3):175-80.
    • (1984) Clays Clay Miner , vol.32 , Issue.3 , pp. 175-180
    • Taylor, R.M.1
  • 45
    • 77955586963 scopus 로고    scopus 로고
    • Hexavalent chromium reduction with scrap iron in continuous-flow system. Part 2: Effect of scrap iron shape and size
    • Gheju M, Balcu I. Hexavalent chromium reduction with scrap iron in continuous-flow system. Part 2: Effect of scrap iron shape and size. J Hazard Mater 2010;182(1):484-93.
    • (2010) J Hazard Mater , vol.182 , Issue.1 , pp. 484-493
    • Gheju, M.1    Balcu, I.2
  • 46
    • 84880565716 scopus 로고    scopus 로고
    • Removal of Cr (VI) with cogeneration of electricity by an alkaline fuel cell reactor
    • Zhang H, Xu W, Wu Z, Zhou M, Jin T. Removal of Cr (VI) with cogeneration of electricity by an alkaline fuel cell reactor. J Phys Chem C 2013;117(28):14479-84.
    • (2013) J Phys Chem C , vol.117 , Issue.28 , pp. 14479-14484
    • Zhang, H.1    Xu, W.2    Wu, Z.3    Zhou, M.4    Jin, T.5
  • 47
    • 84908492397 scopus 로고    scopus 로고
    • Which establishes the maximum permissible limits of pollutants in wastewater discharges into national waters
    • Official Mexican Standard NOM-001-SEMARNAT-1996. Which establishes the maximum permissible limits of pollutants in wastewater discharges into national waters.
    • Official Mexican Standard NOM-001-SEMARNAT-1996
  • 48
    • 40749145992 scopus 로고    scopus 로고
    • Chromate reduction by waste iron from electroplating wastewater using plug flow reactor
    • Shiao-Shing C, Bao-Chrung H, Li-Wei H. Chromate reduction by waste iron from electroplating wastewater using plug flow reactor. J Hazard Mater 2008;152:1092-7.
    • (2008) J Hazard Mater , vol.152 , pp. 1092-1097
    • Shiao-Shing, C.1    Bao-Chrung, H.2    Li-Wei, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.