메뉴 건너뛰기




Volumn 7, Issue , 2014, Pages 305-318

Surgical stapling device–tissue interactions: What surgeons need to know to improve patient outcomes

Author keywords

Anastomosis; Bariatric; Colorectal; Education; Stapler; Thoracic

Indexed keywords

ANASTOMOSIS; BARIATRIC; COLORECTAL; STAPLER; THORACIC;

EID: 84908314061     PISSN: None     EISSN: 11791470     Source Type: Journal    
DOI: 10.2147/MDER.S67338     Document Type: Review
Times cited : (108)

References (60)
  • 1
    • 77249166518 scopus 로고    scopus 로고
    • High incidence of technical errors involving the eea circular stapler: A single institution experience
    • Offodile AC, Feingold DL, Nasar A, Whelan RL, Arnell TD. High incidence of technical errors involving the EEA circular stapler: a single institution experience. J Am Coll Surg. 2010;210(3):331–335.
    • (2010) J am Coll Surg , vol.210 , Issue.3 , pp. 331-335
  • 2
    • 0034858147 scopus 로고    scopus 로고
    • Colorectal anastomotic leak rates are measures of technical skill in surgery
    • Collopy BT. Colorectal anastomotic leak rates are measures of technical skill in surgery. ANZ J Surg. 2001;71(9):508–510.
    • (2001) ANZ J Surg , vol.71 , Issue.9 , pp. 508-510
  • 3
    • 10644244453 scopus 로고    scopus 로고
    • The science of stapling and leaks
    • Baker RS, Foote J, Kemmeter P, et al. The science of stapling and leaks. Obesity surgery. 2004;14(10):1290–1298.
    • (2004) Obesity Surgery , vol.14 , Issue.10 , pp. 1290-1298
  • 4
    • 84880895321 scopus 로고    scopus 로고
    • Device-tissue interactions: A collaborative communications system
    • Chekan E, Whelan RL, Feng AH. Device-tissue interactions: A collaborative communications system. Ann Surg Innov Res. 2013;7(1):10.
    • (2013) Ann Surg Innov Res. , vol.7 , Issue.1 , pp. 10
  • 5
    • 84859192936 scopus 로고    scopus 로고
    • Smaller-diameter circular stapler has an advantage in billroth i stapled anastomosis after laparoscopy-assisted distal gastrectomy
    • Kim MK, Park JM, Choi YS, Chi KC. Smaller-diameter circular stapler has an advantage in Billroth I stapled anastomosis after laparoscopy-assisted distal gastrectomy. J Laparoendosc Adv Surg Tech A. 2012; 22(3):236–241.
    • (2012) J Laparoendosc Adv Surg Tech A , vol.22 , Issue.3 , pp. 236-241
  • 6
    • 0028859429 scopus 로고
    • Influence of cartridge size on the morbidity of esophagojejunal anastomosis with eea stapling devices
    • Fernández-Fernández L, Tejero E, Tieso A. Influence of cartridge size on the morbidity of esophagojejunal anastomosis with EEA stapling devices. Digestive Surg. 1995;12(4):235–237.
    • (1995) Digestive Surg , vol.12 , Issue.4 , pp. 235-237
  • 7
    • 0030028258 scopus 로고    scopus 로고
    • Stapler design and strictures at the esophagogastric anastomosis
    • Berrisford RG, Page RD, Donnelly RJ. Stapler design and strictures at the esophagogastric anastomosis. J Thorac Cardiovasc Surg. 1996;111(1):142–146.
    • (1996) J Thorac Cardiovasc Surg , vol.111 , Issue.1 , pp. 142-146
  • 8
    • 0033899183 scopus 로고    scopus 로고
    • Anastomotic stenoses occurring after circular stapling in esophageal cancer surgery
    • Petrin G, Ruol A, Battaglia G, et al. Anastomotic stenoses occurring after circular stapling in esophageal cancer surgery. Surg Endosc. 2000;14(7):670–674.
    • (2000) Surg Endosc , vol.14 , Issue.7 , pp. 670-674
  • 9
    • 78649966981 scopus 로고    scopus 로고
    • Does circular stapled esophagogastric anastomotic size affect the incidence of postoperative strictures?
    • Yendamuri S, Gutierrez L, Oni A, et al. Does circular stapled esophagogastric anastomotic size affect the incidence of postoperative strictures? J Surg Res. 2011;165(1):1–4.
    • (2011) J Surg Res , vol.165 , Issue.1 , pp. 1-4
  • 10
    • 84908316505 scopus 로고    scopus 로고
    • Impact of gastro-jejunostomy diameter on complications and weight loss after roux-en-y gastric bypass over a 5-year period
    • March 30–April 2, 2011, San Antonio, Texas: Poster PO46. SAGES [webpage on the Internet]. Available from, Accessed April 16
    • Ahad AW, Tilak J, Reiss D, Pilcher J. Impact of gastro-jejunostomy diameter on complications and weight loss after Roux-en-Y gastric bypass over a 5-year period. Poster presented at Society of American Gastrointestinal and Endoscopic Surgeons Meeting, March 30–April 2, 2011, San Antonio, Texas: Poster PO46. SAGES [webpage on the Internet]. Available from: http://www.sages.org/meetings/annual-meeting/abstracts-archive/impact-of-gastro-jejunostomy-diameter-on-complications-and-weight-loss-after-roux-en-y-gastric-bypass-over-a-5-year-period/. Accessed April 16, 2014.
    • (2014) Poster Presented at Society of American Gastrointestinal and Endoscopic Surgeons Meeting
  • 11
    • 84908342616 scopus 로고    scopus 로고
    • Laparoscopic degastro-gastric bypass for gastrojejunal anastomotic stricture: Report of a case (video)
    • Corigliano N, Veyrie N, Abdelhalim A, Stephane S, Lloret Linares C, Bouillot J. Laparoscopic degastro-gastric bypass for gastrojejunal anastomotic stricture: report of a case (video). Obes Surg. 2009;19:1072. 5-1034.
    • (2009) Obes Surg , vol.19 , Issue.1072 , pp. 5-1034
  • 12
    • 58149299807 scopus 로고    scopus 로고
    • The effect of stoma size on weight loss after laparoscopic gastric bypass surgery: Results of a blinded randomized controlled trial
    • Cottam DR, Fisher B, Sridhar V, Atkinson J, Dallal R. The effect of stoma size on weight loss after laparoscopic gastric bypass surgery: results of a blinded randomized controlled trial. Obes Surg. 2009;19(1):13–17.
    • (2009) Obes Surg , vol.19 , Issue.1 , pp. 13-17
  • 13
    • 33947355438 scopus 로고    scopus 로고
    • Incidence of gastroenterostomy stenosis in laparoscopic roux-en-y gastric bypass using 21- or 25-mm circular stapler: A randomized prospective blinded study
    • Fisher BL, Atkinson JD, Cottam D. Incidence of gastroenterostomy stenosis in laparoscopic Roux-en-Y gastric bypass using 21- or 25-mm circular stapler: A randomized prospective blinded study. Surg Obes Relat Dis. 2007;3(2):176–179.
    • (2007) Surg Obes Relat Dis , vol.3 , Issue.2 , pp. 176-179
  • 14
    • 33746059359 scopus 로고    scopus 로고
    • The impact of circular stapler diameter on the incidence of gastrojejunostomy stenosis and weight loss following laparoscopic roux-en-y gastric bypass
    • Gould JC, Garren M, Boll V, Starling J. The impact of circular stapler diameter on the incidence of gastrojejunostomy stenosis and weight loss following laparoscopic Roux-en-Y gastric bypass. Surg Endosc. 2006;20(7):1017–1020.
    • (2006) Surg Endosc , vol.20 , Issue.7 , pp. 1017-1020
  • 15
    • 70549092911 scopus 로고    scopus 로고
    • Risk factors for anastomotic leakage after laparoscopic intracorporeal colorectal anastomosis with a double stapling technique
    • Kim JS, Cho SY, Min BS, Kim NK. Risk factors for anastomotic leakage after laparoscopic intracorporeal colorectal anastomosis with a double stapling technique. J Am Coll Surg. 2009;209(6):694–701.
    • (2009) J am Coll Surg , vol.209 , Issue.6 , pp. 694-701
  • 16
    • 0347481284 scopus 로고    scopus 로고
    • Incidence and outcome of anastomotic stricture after laparoscopic gastric bypass
    • discussion 1003
    • Nguyen NT, Stevens CM, Wolfe BM. Incidence and outcome of anastomotic stricture after laparoscopic gastric bypass. J Gastrointest Surg. 2003;7(8):997–1003; discussion 1003.
    • (2003) J Gastrointest Surg. , vol.7 , Issue.8 , pp. 997-1003
  • 17
    • 79960408864 scopus 로고    scopus 로고
    • Impact of gastrojejunostomy diameter on long-term weight loss following laparoscopic gastric bypass: A follow-up study
    • Smith C, Garren M, Gould J. Impact of gastrojejunostomy diameter on long-term weight loss following laparoscopic gastric bypass: A follow-up study. Surg Endosc. 2011;25(7):2164–2167.
    • (2011) Surg Endosc , vol.25 , Issue.7 , pp. 2164-2167
  • 18
    • 34548847757 scopus 로고    scopus 로고
    • Complications at gastrojejunostomy after laparoscopic roux-en-y gastric bypass: Comparison between 21- and 25-mm circular staplers
    • Suggs WJ, Kouli W, Lupovici M, Chau WY, Brolin RE. Complications at gastrojejunostomy after laparoscopic Roux-en-Y gastric bypass: comparison between 21- and 25-mm circular staplers. Surg Obes Relat Dis. 2007;3(5):508–514.
    • (2007) Surg Obes Relat Dis , vol.3 , Issue.5 , pp. 508-514
  • 19
    • 35748931184 scopus 로고    scopus 로고
    • Predictors, treatment, and outcomes of gastrojejunostomy stricture after gastric bypass for morbid obesity
    • Takata MC, Ciovica R, Cello JP, Posselt AM, Rogers SJ, Campos GM. Predictors, treatment, and outcomes of gastrojejunostomy stricture after gastric bypass for morbid obesity. Obes Surg. 2007;17(7): 878–884.
    • (2007) Obes Surg , vol.17 , Issue.7 , pp. 878-884
  • 20
    • 0032735020 scopus 로고    scopus 로고
    • Jejunal pouch to avoid stricture after esophagojejunostomy with circular stapler
    • Tokunaga Y, Ryo J, Kitaoka A, Yagi T, Tokuka A, Ohsumi K. Jejunal pouch to avoid stricture after esophagojejunostomy with circular stapler. J Am Coll Surg. 1999;189(5):466–469.
    • (1999) J am Coll Surg , vol.189 , Issue.5 , pp. 466-469
  • 21
    • 0030749511 scopus 로고    scopus 로고
    • Factors associated with the occurrence of leaks in stapled rectal anastomoses: A review of 1,014 patients
    • Vignali A, Fazio VW, Lavery IC, et al. Factors associated with the occurrence of leaks in stapled rectal anastomoses: a review of 1,014 patients. J Am Coll Surg. 1997;185(2):105–113.
    • (1997) J am Coll Surg , vol.185 , Issue.2 , pp. 105-113
  • 22
    • 0025042870 scopus 로고
    • Non-suture anastomosis: The historical development
    • Hardy KJ. Non-suture anastomosis: the historical development. Aust N Z J Surg. 1990;60(8):625–633.
    • (1990) Aust N Z J Surg , vol.60 , Issue.8 , pp. 625-633
  • 23
    • 10644235951 scopus 로고
    • Investigation of processes relating to tissue compression in suturing and stapling apparatus
    • Astafiev GV. Investigation of processes relating to tissue compression in suturing and stapling apparatus. Chirurgicheskiey Shivayushiye Apparaty. 1967;7:22–31.
    • (1967) Chirurgicheskiey Shivayushiye Apparaty , vol.7 , pp. 22-31
  • 24
    • 79951726669 scopus 로고    scopus 로고
    • Smaller staple height for circular stapled gastrojejunostomy in laparoscopic gastric bypass: Early results in 1,074 morbidly obese patients
    • Sakran N, Assalia A, Sternberg A, et al. Smaller staple height for circular stapled gastrojejunostomy in laparoscopic gastric bypass: early results in 1,074 morbidly obese patients. Obes Surg. 2011;21(2):238–243.
    • (2011) Obes Surg , vol.21 , Issue.2 , pp. 238-243
  • 25
    • 80055073545 scopus 로고    scopus 로고
    • The effect of tissue compression on circular stapler line failure
    • Myers SR, Rothermel WS Jr, Shaffer L. The effect of tissue compression on circular stapler line failure. Surg Endosc. 2011;25(9):3043–3049.
    • (2011) Surg Endosc , vol.25 , Issue.9 , pp. 3043-3049
  • 26
    • 84858697994 scopus 로고    scopus 로고
    • Shorter circular staple is height associated with lower anastomotic stricture rate in laparoscopic gastric bypass
    • Hanna K, Seder CW, Chengelis D, McCullough PA, Krause K. Shorter circular staple is height associated with lower anastomotic stricture rate in laparoscopic gastric bypass. Surg Obes Relat Dis. 2012;8(2):181–184.
    • (2012) Surg Obes Relat Dis , vol.8 , Issue.2 , pp. 181-184
  • 27
    • 77957561735 scopus 로고    scopus 로고
    • Effect of staple height on gastrojejunostomy during laparoscopic gastric bypass: A multicenter prospective randomized trial
    • Nguyen NT, Dakin G, Needleman B, et al. Effect of staple height on gastrojejunostomy during laparoscopic gastric bypass: A multicenter prospective randomized trial. Surg Obes Relat Dis. 2010;6(5):477–482.
    • (2010) Surg Obes Relat Dis , vol.6 , Issue.5 , pp. 477-482
  • 28
    • 33745018472 scopus 로고    scopus 로고
    • Tissue thickness of human stomach measured on excised gastric specimens from obese patients
    • Elariny H, González H, Wang B. Tissue thickness of human stomach measured on excised gastric specimens from obese patients. Surg Technol Int. 2005;14:119–124.
    • (2005) Surg Technol Int , vol.14 , pp. 119-124
  • 29
    • 84878508403 scopus 로고    scopus 로고
    • Pancreatic thickness as a predictive factor for postoperative pancreatic fistula after distal pancreatectomy using an endopath stapler
    • Okano K, Oshima M, Kakinoki K, et al. Pancreatic thickness as a predictive factor for postoperative pancreatic fistula after distal pancreatectomy using an endopath stapler. Surg Today. 2013;43(2): 141–147.
    • (2013) Surg Today , vol.43 , Issue.2 , pp. 141-147
  • 30
    • 79960401632 scopus 로고    scopus 로고
    • The importance of precompression time for secure stapling with a linear stapler
    • Nakayama S, Hasegawa S, Nagayama S, et al. The importance of precompression time for secure stapling with a linear stapler. Surg Endosc. 2011;25(7):2382–2386.
    • (2011) Surg Endosc , vol.25 , Issue.7 , pp. 2382-2386
  • 31
    • 79954419403 scopus 로고    scopus 로고
    • Prolonged peri-firing compression with a linear stapler prevents pancreatic fistula in laparoscopic distal pancreatectomy
    • Nakamura M, Ueda J, Kohno H, et al. Prolonged peri-firing compression with a linear stapler prevents pancreatic fistula in laparoscopic distal pancreatectomy. Surg Endosc. 2011;25(3):867–871.
    • (2011) Surg Endosc , vol.25 , Issue.3 , pp. 867-871
  • 32
    • 84863843136 scopus 로고    scopus 로고
    • Don’t get burned from lack of knowledge
    • Schwaitzberg SD, Jones DB. Don’t get burned from lack of knowledge. Ann Surg. 2012;256(2):219–220.
    • (2012) Ann Surg , vol.256 , Issue.2 , pp. 219-220
  • 33
    • 84871623523 scopus 로고    scopus 로고
    • Fuse (fundamental use of surgical energy™) task force. Surgeons don’t know what they don’t know about the safe use of energy in surgery
    • Feldman LS, Fuchshuber P, Jones DB, Mischna J, Schwaitzberg SD; FUSE (Fundamental Use of Surgical Energy™) Task Force. Surgeons don’t know what they don’t know about the safe use of energy in surgery. Surg Endosc. 2012;26(10):2735–2739.
    • (2012) Surg Endosc , vol.26 , Issue.10 , pp. 2735-2739
  • 34
    • 71549126520 scopus 로고    scopus 로고
    • The effect of a focused instructional session on knowledge of surgical staplers in general surgery residents
    • McColl RJ, Karmali S, Reso A, Paolucci E, Sherman V. The effect of a focused instructional session on knowledge of surgical staplers in general surgery residents. J Surg Educ. 2009;66(5):288–291.
    • (2009) J Surg Educ , vol.66 , Issue.5 , pp. 288-291
  • 35
    • 84855938792 scopus 로고    scopus 로고
    • Influence of the stapler size used in esophagojejunostomy anastomosis: Anastomotic leak and strictures after total gastrectomy
    • Çakabay B, Aksel B, Ünal E, et al. Influence of the stapler size used in esophagojejunostomy anastomosis: anastomotic leak and strictures after total gastrectomy. Turkiye Klinikleri J Med Sci. 2012;32(2): 428–431.
    • (2012) Turkiye Klinikleri J Med Sci , vol.32 , Issue.2 , pp. 428-431
  • 36
    • 0025081684 scopus 로고
    • Sutures, staplers, leaks and strictures. A review of anastomoses in oesophageal resection at royal victoria hospital, belfast 1977–1986
    • McManus KG, Ritchie AJ, McGuigan J, Stevenson HM, Gibbons JR. Sutures, staplers, leaks and strictures. A review of anastomoses in oesophageal resection at Royal Victoria Hospital, Belfast 1977–1986. Eur J Cardiothorac Surg. 1990;4(2):97–100.
    • (1990) Eur J Cardiothorac Surg. , vol.4 , Issue.2 , pp. 97-100
  • 37
    • 77957679410 scopus 로고    scopus 로고
    • Bariatric surgery: A primer
    • Karmali S, Johnson Stoklossa C, Sharma A, et al. Bariatric surgery: a primer. Can Fam Physician. 2010;56(9):873–879.
    • (2010) Can Fam Physician , vol.56 , Issue.9 , pp. 873-879
  • 38
    • 77954974824 scopus 로고    scopus 로고
    • Michigan bariatric surgery collaborative. Hospital complication rates with bariatric surgery in michigan
    • Birkmeyer NJ, Dimick JB, Share D, et al; Michigan Bariatric Surgery Collaborative. Hospital complication rates with bariatric surgery in Michigan. JAMA. 2010;304(4):435–442.
    • (2010) JAMA , vol.304 , Issue.4 , pp. 435-442
  • 39
    • 58249140072 scopus 로고    scopus 로고
    • Colonic anastomotic leak: Risk factors, diag-nosis, and treatment
    • Kingham TP, Pachter HL. Colonic anastomotic leak: risk factors, diag-nosis, and treatment. J Am Coll Surg. 2009;208(2):269–278.
    • (2009) J am Coll Surg , vol.208 , Issue.2 , pp. 269-278
  • 40
    • 0034861721 scopus 로고    scopus 로고
    • Locoregional recurrence in patients with anastomotic leakage after anterior resection for rectal carcinoma
    • Merkel S, Wang WY, Schmidt O, et al. Locoregional recurrence in patients with anastomotic leakage after anterior resection for rectal carcinoma. Colorectal Dis. 2001;3(3):154–160.
    • (2001) Colorectal Dis , vol.3 , Issue.3 , pp. 154-160
  • 41
    • 0142185020 scopus 로고    scopus 로고
    • Anastomotic leakage after curative anterior resection results in a higher prevalence of local recurrence
    • Bell SW, Walker KG, Rickard MJ, et al. Anastomotic leakage after curative anterior resection results in a higher prevalence of local recurrence. Br J Surg. 2003;90(10):1261–1266.
    • (2003) Br J Surg , vol.90 , Issue.10 , pp. 1261-1266
  • 42
    • 0035068268 scopus 로고    scopus 로고
    • Outcome and late functional results after anastomotic leakage following mesorectal excision for rectal cancer
    • Nesbakken A, Nygaard K, Lunde OC. Outcome and late functional results after anastomotic leakage following mesorectal excision for rectal cancer. Br J Surg. 2001;88(3):400–404.
    • (2001) Br J Surg , vol.88 , Issue.3 , pp. 400-404
  • 43
    • 0035044853 scopus 로고    scopus 로고
    • Ct of bowel wall thickening: Significance and pitfalls of interpretation
    • Macari M, Balthazar EJ. CT of bowel wall thickening: significance and pitfalls of interpretation. AJR Am J Roentgenol. 2001;176(5): 1105–1116.
    • (2001) AJR am J Roentgenol , vol.176 , Issue.5 , pp. 1105-1116
  • 44
    • 1542289131 scopus 로고    scopus 로고
    • Laparoscopic total mesorectal excision (tme) for rectal cancer surgery: Long-term outcomes
    • Leroy J, Jamali F, Forbes L, et al. Laparoscopic total mesorectal excision (TME) for rectal cancer surgery: long-term outcomes. Surg Endosc. 2004;18(2):281–289.
    • (2004) Surg Endosc , vol.18 , Issue.2 , pp. 281-289
  • 45
    • 84873292965 scopus 로고    scopus 로고
    • Can a curved stapler made for open surgery be useful in laparoscopic lower rectal resections? Technique and experience of a single centre
    • Mari FS, Gasparrini M, Nigri G, et al. Can a curved stapler made for open surgery be useful in laparoscopic lower rectal resections? Technique and experience of a single centre. Surgeon. 2013;11 Supplement 1:S23–S26.
    • (2013) Surgeon , vol.11 , pp. S23-S26
  • 46
    • 0028890914 scopus 로고
    • Use of the circular stapler in 1000 consecutive colorectal anastomoses: Experience of one surgical team
    • Detry RJ, Kartheuser A, Delriviere L, Saba J, Kestens PJ. Use of the circular stapler in 1000 consecutive colorectal anastomoses: experience of one surgical team. Surgery. 1995;117(2):140–145.
    • (1995) Surgery , vol.117 , Issue.2 , pp. 140-145
  • 47
    • 33947280933 scopus 로고    scopus 로고
    • Long-term results show triple stapling facilitates safe low colorectal and coloanal anastomosis and is associated with low rates of local recurrence after anterior resection for rectal cancer
    • Edwards DP, Sexton R, Heald RJ, Moran BJ. Long-term results show triple stapling facilitates safe low colorectal and coloanal anastomosis and is associated with low rates of local recurrence after anterior resection for rectal cancer. Tech Coloproctol. 2007;11(1):17–21.
    • (2007) Tech Coloproctol , vol.11 , Issue.1 , pp. 17-21
  • 48
    • 84908344850 scopus 로고    scopus 로고
    • Endoscopic thoracic surgery for lung cancer: Mastering tools to optimize patient outcomes; 2011
    • [webpage on the Internet]. Available from:, Accessed April 16
    • Pickens A. Endoscopic thoracic surgery for lung cancer: mastering tools to optimize patient outcomes; 2011. General Surgery News [webpage on the Internet]. Available from: http://www.generalsurgerynews.com/ViewArticle.aspx?d=Procedural+Breakth rough&d_id=267&i=June2011&i_id=736&a_id=17235. Accessed April 16, 2014.
    • (2014) General surgery news
  • 49
    • 84869127561 scopus 로고    scopus 로고
    • The utility of biclamp(®) for intraoperative air leakage control in video-assisted thoracic surgery for pulmonary lobectomy
    • ®) for intraoperative air leakage control in video-assisted thoracic surgery for pulmonary lobectomy. Gen Thorac Cardiovasc Surg. 2012;60(11):781–783.
    • (2012) Gen Thorac Cardiovasc Surg , vol.60 , Issue.11 , pp. 781-783
  • 50
    • 84864742725 scopus 로고    scopus 로고
    • Prolonged air leak after lung resection
    • Hunt BM, Aye RW. Prolonged air leak after lung resection. Curr Respir Med Rev. 2012;8(4):280–284.
    • (2012) Curr Respir Med Rev , vol.8 , Issue.4 , pp. 280-284
  • 51
    • 0028859766 scopus 로고
    • A solution to prolonged air leak after video-assisted thoracoscopic lobectomy
    • Bhatnagar NK, Berndt S. A solution to prolonged air leak after video-assisted thoracoscopic lobectomy. Ann Thorac Surg. 1995;59(1): 260–261.
    • (1995) Ann Thorac Surg , vol.59 , Issue.1 , pp. 260-261
  • 52
    • 15944365161 scopus 로고    scopus 로고
    • Characterization and importance of air leak after lobectomy
    • Okereke I, Murthy SC, Alster JM, Blackstone EH, Rice TW. Characterization and importance of air leak after lobectomy. Ann Thorac Surg. 2005;79(4):1167–1173.
    • (2005) Ann Thorac Surg , vol.79 , Issue.4 , pp. 1167-1173
  • 53
    • 0031864053 scopus 로고    scopus 로고
    • Cartilage folding method for main bronchial stapling
    • Aoki T, Ozeki Y, Watanabe M, Tanaka S. Cartilage folding method for main bronchial stapling. Ann Thorac Surg. 1998;65(6): 1800–1801.
    • (1998) Ann Thorac Surg , vol.65 , Issue.6 , pp. 1800-1801
  • 54
    • 74549178696 scopus 로고    scopus 로고
    • Thoracoscopic lobectomy is associated with lower morbidity than open lobectomy: A propensity-matched analysis from the sts database
    • Paul S, Altorki NK, Sheng S, et al. Thoracoscopic lobectomy is associated with lower morbidity than open lobectomy: A propensity-matched analysis from the STS database. J Thorac Cardiovasc Surg. 2010;139(2):366–378.
    • (2010) J Thorac Cardiovasc Surg , vol.139 , Issue.2 , pp. 366-378
  • 55
    • 67651099044 scopus 로고    scopus 로고
    • Thoracoscopic lobectomy is associated with lower morbidity compared with t horacot omy
    • Villamizar NR, Darrabie MD, Burfeind WR, et al. Thoracoscopic lobectomy is associated with lower morbidity compared with t horacot omy. J Thorac Cardi ovasc Surg. 2009; 138(2): 419–425.
    • (2009) J Thorac Cardi Ovasc Surg , vol.138 , Issue.2 , pp. 419-425
  • 56
    • 84859076524 scopus 로고    scopus 로고
    • Video-assisted thoracoscopic lobectomy is less costly and morbid than open lobectomy: A retrospective multiinstitutional database analysis
    • Swanson SJ, Meyers BF, Gunnarsson CL, et al. Video-assisted thoracoscopic lobectomy is less costly and morbid than open lobectomy: A retrospective multiinstitutional database analysis. Ann Thorac Surg. 2012;93(4):1027–1032.
    • (2012) Ann Thorac Surg , vol.93 , Issue.4 , pp. 1027-1032
  • 57
    • 79551572078 scopus 로고    scopus 로고
    • Is surgical morbidity decreased with minimally invasive lobectomy?
    • Park BJ. Is surgical morbidity decreased with minimally invasive lobectomy? Cancer J. 2011;17(1):18–22.
    • (2011) Cancer J , vol.17 , Issue.1 , pp. 18-22
  • 58
    • 58149186987 scopus 로고    scopus 로고
    • Pitfalls related to the use of endostaplers during video-assisted thoracic surgery
    • Gossot D, Merlusca G, Tudor A, Boudaya MS, Radu C, Magdeleinat P. Pitfalls related to the use of endostaplers during video-assisted thoracic surgery. Surg Endosc. 2009;23(1):189–192.
    • (2009) Surg Endosc , vol.23 , Issue.1 , pp. 189-192
  • 59
    • 84908320120 scopus 로고    scopus 로고
    • Data on file. Comparison of the number of malformed staple legs in 2–5 mm thick excised porcine stomach of the covidien endo gia universal roticulator 60 and the ethicon endo-surgery echelon flex 60 endoscopic linear surgical staplers. white paper
    • INC. Cincinnati, Ohio
    • Gonzalez H, Avimukta K, Hall S. Data on file. Comparison of the number of malformed staple legs in 2–5 mm thick excised porcine stomach of the covidien Endo GIA Universal Roticulator 60 and the Ethicon Endo-Surgery Echelon FLEX 60 endoscopic linear surgical staplers. White paper. ETHICON ENDO-SURGERY, INC. Cincinnati, Ohio. 2010.
    • (2010) Ethicon Endo-Surgery
  • 60
    • 80051544840 scopus 로고    scopus 로고
    • Incidence of and risk factors for anastomotic leakage after laparoscopic anterior resection with intracorporeal rectal transection and double-stapling technique anastomosis for rectal cancer
    • Akiyoshi T, Ueno M, Fukunaga Y, et al. Incidence of and risk factors for anastomotic leakage after laparoscopic anterior resection with intracorporeal rectal transection and double-stapling technique anastomosis for rectal cancer. Am J Surg. 2011;202(3):259–264.
    • (2011) Am J Surg , vol.202 , Issue.3 , pp. 259-264


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.