메뉴 건너뛰기




Volumn 10, Issue 6, 2014, Pages 724-731

Differences in vessel healing following delivery of everolimus or paclitaxel: A comparative experimental study using identical stent and biodegradable polymer platforms

Author keywords

Biodegradable polymer; Everolimus eluting stent; Paclitaxel eluting stent; Porcine coronary model

Indexed keywords

EVEROLIMUS; PACLITAXEL;

EID: 84908296631     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV10I6A125     Document Type: Article
Times cited : (9)

References (26)
  • 3
    • 84861371093 scopus 로고    scopus 로고
    • Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: A pooled analysis of individual patient data from the ISAR-TEST 3, ISARTEST 4, and LEADERS randomized trials
    • Stefanini GG, Byrne RA, Serruys PW, de Waha A, Meier B, Massberg S, Juni P, Schomig A, Windecker S, Kastrati A. Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISARTEST 4, and LEADERS randomized trials. Eur Heart J. 2012;33:1214-22.
    • (2012) Eur Heart J , vol.33 , pp. 1214-1222
    • Stefanini, G.G.1    Byrne, R.A.2    Serruys, P.W.3    De Waha, A.4    Meier, B.5    Massberg, S.6    Juni, P.7    Schomig, A.8    Windecker, S.9    Kastrati, A.10
  • 5
    • 84856109118 scopus 로고    scopus 로고
    • Differential neointimal response to the implantation of coronary bare metal and everolimus-eluting stents in familial hypercholesterolemic swine
    • Huibregtse B, Pennington D. Differential neointimal response to the implantation of coronary bare metal and everolimus-eluting stents in familial hypercholesterolemic swine. J Am Coll Cardiol. 2010;56;B53.
    • (2010) J Am Coll Cardiol , vol.56 , pp. B53
    • Huibregtse, B.1    Pennington, D.2
  • 7
    • 84883237196 scopus 로고    scopus 로고
    • Comparable clinical safety and efficacy of biodegradable versus durable polymer paclitaxel eluting stents despite shorter dual antiplatelet therapy: Insights from a multicenter, propensity score-matched registry
    • Buszman PP, Orlik B, Trela B, Milewski K, Kozlowski M, Pruski M Jr, Drzewiecki J, Peppas A, Granada JF, Kaluza GL, Buszman PE. Comparable clinical safety and efficacy of biodegradable versus durable polymer paclitaxel eluting stents despite shorter dual antiplatelet therapy: insights from a multicenter, propensity score-matched registry. Catheter Cardiovasc Interv. 2013;82:E155-62.
    • (2013) Catheter Cardiovasc Interv , vol.82 , pp. E155-E162
    • Buszman, P.P.1    Orlik, B.2    Trela, B.3    Milewski, K.4    Kozlowski, M.5    Pruski, M.6    Drzewiecki, J.7    Peppas, A.8    Granada, J.F.9    Kaluza, G.L.10    Buszman, P.E.11
  • 8
    • 73949122498 scopus 로고    scopus 로고
    • Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): A randomised trial
    • Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, Smits PC. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE): a randomised trial. Lancet. 2010;375:201-9.
    • (2010) Lancet , vol.375 , pp. 201-209
    • Kedhi, E.1    Joesoef, K.S.2    McFadden, E.3    Wassing, J.4    Van Mieghem, C.5    Goedhart, D.6    Smits, P.C.7
  • 9
    • 84864542109 scopus 로고    scopus 로고
    • Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial
    • Achremczyk M. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial. Kardiol Pol. 2012;70:762-3.
    • (2012) Kardiol Pol , vol.70 , pp. 762-763
    • Achremczyk, M.1
  • 10
    • 84908296623 scopus 로고    scopus 로고
    • Principles of care of laboratory animals
    • inst Institute of Laboratory Animal Resources NRC
    • Institute of Laboratory Animal Resources NRC. Principles of care of laboratory animals. NIH Publication. 1996; No. 85-23.
    • (1996) NIH Publication , Issue.85-123
  • 12
    • 0031885670 scopus 로고    scopus 로고
    • In-stent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia
    • Kornowski R, Hong MK, Tio FO, Bramwell O, Wu H, Leon MB. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia. J Am Coll Cardiol. 1998;31:224-30.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 224-230
    • Kornowski, R.1    Hong, M.K.2    Tio, F.O.3    Bramwell, O.4    Wu, H.5    Leon, M.B.6
  • 15
    • 73949089126 scopus 로고    scopus 로고
    • Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: The Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial
    • Byrne RA, Kastrati A, Kufner S, Massberg S, Birkmeier KA, Laugwitz KL, Schulz S, Pache J, Fusaro M, Seyfarth M, Schömig A, Mehilli J; Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Investigators. Randomized, non-inferiority trial of three limus agent-eluting stents with different polymer coatings: the Intracoronary Stenting and Angiographic Results: Test Efficacy of 3 Limus-Eluting Stents (ISAR-TEST-4) Trial. Eur Heart J. 2009;30:2441-9.
    • (2009) Eur Heart J , vol.30 , pp. 2441-2449
    • Byrne, R.A.1    Kastrati, A.2    Kufner, S.3    Massberg, S.4    Birkmeier, K.A.5    Laugwitz, K.L.6    Schulz, S.7    Pache, J.8    Fusaro, M.9    Seyfarth, M.10    Schömig, A.11    Mehilli, J.12
  • 18
    • 21844467014 scopus 로고    scopus 로고
    • Comparative study of tacrolimus and paclitaxel stent coating in the porcine coronary model
    • Scheller B, Grandt A, Wnendt S, Lorenz G, Bohm M, Nickenig G. Comparative study of tacrolimus and paclitaxel stent coating in the porcine coronary model. Z Kardiol. 2005;94:445-52.
    • (2005) Z Kardiol , vol.94 , pp. 445-452
    • Scheller, B.1    Grandt, A.2    Wnendt, S.3    Lorenz, G.4    Bohm, M.5    Nickenig, G.6
  • 23
    • 67651097489 scopus 로고    scopus 로고
    • Drug-eluting stents in animals and patients: Where do we stand today?
    • Drachman DE. Drug-eluting stents in animals and patients: where do we stand today? Circulation. 2009;120:101-3.
    • (2009) Circulation , vol.120 , pp. 101-103
    • Drachman, D.E.1
  • 26
    • 85032491011 scopus 로고    scopus 로고
    • Everolimus versus paclitaxel eluting biodegradable polymer coated stents for coronary revascularisation: Clinical and angiographic results from the pivotal randomised trial
    • Trznadel S, Buszman PP, Milewski K, Król M, Gorycki B, Janusz P, Zurakowski A, Wojakowski W, Buszman PE. Everolimus versus paclitaxel eluting biodegradable polymer coated stents for coronary revascularisation: clinical and angiographic results from the pivotal randomised trial. Eur Heart J. 2013;34:P3050.
    • (2013) Eur Heart J , vol.34 , pp. P3050
    • Trznadel, S.1    Buszman, P.P.2    Milewski, K.3    Król, M.4    Gorycki, B.5    Janusz, P.6    Zurakowski, A.7    Wojakowski, W.8    Buszman, P.E.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.