메뉴 건너뛰기




Volumn 7, Issue 10, 2014, Pages e137-e139

Transapical mitral implantation of a balloon-expandable valve in native mitral valve stenosis in a patient with previous transcatheter aortic valve replacement

Author keywords

balloon expandable; implantation; mitral stenosis; mitral valve; transapical

Indexed keywords

ADULT; CARDIAC IMAGING; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; LUNG PRESSURE; MITRAL VALVE PROSTHESIS; MITRAL VALVE REPLACEMENT; MITRAL VALVE STENOSIS; NOTE; SAPIEN XT VALVE; TRANSAPICAL MITRAL IMPLANTATION; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TREATMENT OUTCOME; AORTA VALVE; DEVICES; DOPPLER ECHOCARDIOGRAPHY; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HEMODYNAMICS; MIDDLE AGED; PATHOPHYSIOLOGY; PROCEDURES; PROSTHESIS; SEVERITY OF ILLNESS INDEX; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSLUMINAL VALVULOPLASTY;

EID: 84908152899     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2014.02.024     Document Type: Article
Times cited : (20)

References (4)
  • 1
    • 84881123250 scopus 로고    scopus 로고
    • First in human transapical implantation of an inverted transcatheter aortic valve prosthesis to treat native mitral valve stenosis
    • R. Hasan, V.S. Mahadevan, H. Schneider, and B. Clarke First in human transapical implantation of an inverted transcatheter aortic valve prosthesis to treat native mitral valve stenosis Circulation 128 2013 e74 e76
    • (2013) Circulation , vol.128 , pp. 74-e76
    • Hasan, R.1    Mahadevan, V.S.2    Schneider, H.3    Clarke, B.4
  • 2
    • 84883790666 scopus 로고    scopus 로고
    • Transcatheter mitral valve replacement using a balloon-expandable prosthesis in a patient with calcified native mitral valve stenosis
    • J.M. Sinning, F. Mellert, W. Schiller, A. Welz, G. Nickenig, and C. Hammerstingl Transcatheter mitral valve replacement using a balloon-expandable prosthesis in a patient with calcified native mitral valve stenosis Eur Heart J 34 2013 2609
    • (2013) Eur Heart J , vol.34 , pp. 2609
    • Sinning, J.M.1    Mellert, F.2    Schiller, W.3    Welz, A.4    Nickenig, G.5    Hammerstingl, C.6
  • 3
    • 84880614039 scopus 로고    scopus 로고
    • The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: A prospective, multicenter, controlled trial
    • R.K. Binder, J.G. Webb, and A.B. Willson The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial J Am Coll Cardiol 62 2013 431 438
    • (2013) J Am Coll Cardiol , vol.62 , pp. 431-438
    • Binder, R.K.1    Webb, J.G.2    Willson, A.B.3
  • 4
    • 84866396204 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation using the slow balloon inflation technique: Making balloon-expandable valves partially repositionable
    • M. Mok, E. Dumont, D. Doyle, and J. Rodes-Cabau Transcatheter aortic valve implantation using the slow balloon inflation technique: making balloon-expandable valves partially repositionable J Card Surg 27 2012 546 548
    • (2012) J Card Surg , vol.27 , pp. 546-548
    • Mok, M.1    Dumont, E.2    Doyle, D.3    Rodes-Cabau, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.