메뉴 건너뛰기




Volumn 52, Issue 11, 2014, Pages e253-e255

False-positive D-dimer result in a latex-enhanced immunoassay caused by interfering human anti-mouse antibodies

Author keywords

D dimer; heterophilic antibodies; human anti mouse antibodies; interference

Indexed keywords

AMINOTRANSFERASE; ANTITHROMBIN; C REACTIVE PROTEIN; CREATININE; D DIMER; HUMAN ANTIMOUSE ANTIBODY; HUMAN IMMUNOGLOBULIN; RHEUMATOID FACTOR; UNCLASSIFIED DRUG; ANTIBODY; FIBRIN DEGRADATION PRODUCT; FIBRIN FRAGMENT D; LATEX;

EID: 84908084335     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2014-0496     Document Type: Letter
Times cited : (11)

References (7)
  • 1
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • Kricka LJ. Human anti-animal antibody interferences in immunological assays. Clin Chem 1999;45:942-56
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 2
    • 0037934622 scopus 로고    scopus 로고
    • Screening for interference in immunoassays
    • Emerson JF, Ngo G, Emerson SS. Screening for interference in immunoassays. Clin Chem 2003;49:1163-9
    • (2003) Clin Chem , vol.49 , pp. 1163-1169
    • Emerson, J.F.1    Ngo, G.2    Emerson, S.S.3
  • 3
    • 0036839769 scopus 로고    scopus 로고
    • False-positive immunoassay results: A multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries
    • Marks V. False-positive immunoassay results: a multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries. Clin Chem 2002;48:2008-16
    • (2002) Clin Chem , vol.48 , pp. 2008-2016
    • Marks, V.1
  • 5
    • 51949103150 scopus 로고    scopus 로고
    • Discrepancy between two methods of D-dimers measurement: One case of human anti-mouse antibody interference
    • Rouviere JA, Devignes J, de Maistre E, Kennel A, Chabot F, Lecompte T. Discrepancy between two methods of D-dimers measurement: one case of human anti-mouse antibody interference. Ann Biol Clin 2008;66:441-6
    • (2008) Ann Biol Clin , vol.66 , pp. 441-446
    • Rouviere, J.A.1    Devignes, J.2    De Maistre, E.3    Kennel, A.4    Chabot, F.5    Lecompte, T.6
  • 7
    • 84856522611 scopus 로고    scopus 로고
    • Heterophilic antibody interference in commercial immunoassays: A screening study using paired native and pre-blocked sera
    • Bolstad N, Warren DJ, Bjerner J, Kravdal G, Schwettmann L, Olsen KH, et al. Heterophilic antibody interference in commercial immunoassays: a screening study using paired native and pre-blocked sera. Clin Chem Lab Med 2011;49:2001-6.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 2001-2006
    • Bolstad, N.1    Warren, D.J.2    Bjerner, J.3    Kravdal, G.4    Schwettmann, L.5    Olsen, K.H.6