메뉴 건너뛰기




Volumn 140, Issue , 2014, Pages 27-32

Multicalibrational procedure for more reliable analyses of ions at low analyte concentrations

Author keywords

ion selective electrodes; non equilibrium sensors; potentiometry

Indexed keywords

ANALYTE CONCENTRATION; NON EQUILIBRIUM; POTENTIOMETRY;

EID: 84908012637     PISSN: 00134686     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.electacta.2014.02.091     Document Type: Article
Times cited : (19)

References (29)
  • 2
    • 33744799995 scopus 로고    scopus 로고
    • Chemo/bio-sensor networks
    • R. Byrne, and D. Diamond Chemo/bio-sensor networks Nat. Mater. 5 2006 421
    • (2006) Nat. Mater. , vol.5 , pp. 421
    • Byrne, R.1    Diamond, D.2
  • 4
    • 79952008279 scopus 로고    scopus 로고
    • Non-equilibrium potentiometry- The very essence
    • A. Lewenstam Non-equilibrium potentiometry- the very essence J. Solid State Electr. 15 2011 15
    • (2011) J. Solid State Electr. , vol.15 , pp. 15
    • Lewenstam, A.1
  • 6
    • 84872425288 scopus 로고    scopus 로고
    • A tutorial on the application of ion-selective electrode potentiometry: An analytical method with unique qualities, unexplored opportunities and potential pitfalls; Tutorial
    • E. Lindner, and B.D. Pendley A tutorial on the application of ion-selective electrode potentiometry: an analytical method with unique qualities, unexplored opportunities and potential pitfalls; tutorial Anal. Chim. Acta 762 2013 1
    • (2013) Anal. Chim. Acta , vol.762 , pp. 1
    • Lindner, E.1    Pendley, B.D.2
  • 7
    • 78650012654 scopus 로고    scopus 로고
    • A study on lowering the detection limit with solid-state lead-selective electrodes
    • G. Lisak, T. Sokalski, J. Bobacka, L. Harju, and A. Lewenstam A study on lowering the detection limit with solid-state lead-selective electrodes Talanta 83 2010 436
    • (2010) Talanta , vol.83 , pp. 436
    • Lisak, G.1    Sokalski, T.2    Bobacka, J.3    Harju, L.4    Lewenstam, A.5
  • 8
    • 80054968756 scopus 로고    scopus 로고
    • Tuned galvanostatic polarization of solid-state lead-selective electrodes for lowering of the detection limit
    • G. Lisak, T. Sokalski, J. Bobacka, L. Harju, K. Mikhelson, and A. Lewenstam Tuned galvanostatic polarization of solid-state lead-selective electrodes for lowering of the detection limit Anal. Chim. Acta 707 2011 1
    • (2011) Anal. Chim. Acta , vol.707 , pp. 1
    • Lisak, G.1    Sokalski, T.2    Bobacka, J.3    Harju, L.4    Mikhelson, K.5    Lewenstam, A.6
  • 9
    • 84872547646 scopus 로고    scopus 로고
    • Determination of lead(II) in groundwater using solid-state lead(II) selective electrodes by tuned galvanostatic polarization
    • G. Lisak, F. Ciepiela, J. Bobacka, T. Sokalski, L. Harju, and A. Lewenstam Determination of lead(II) in groundwater using solid-state lead(II) selective electrodes by tuned galvanostatic polarization Electroanal. 25 2013 123
    • (2013) Electroanal. , vol.25 , pp. 123
    • Lisak, G.1    Ciepiela, F.2    Bobacka, J.3    Sokalski, T.4    Harju, L.5    Lewenstam, A.6
  • 10
    • 84873386298 scopus 로고    scopus 로고
    • Solid-contact ion-selective electrodes with highly selective thioamide derivatives of p-tert-butylcalixarene for the determination of lead(II) in environmental samples
    • M. Guzinski, G. Lisak, T. Sokalski, J. Bobacka, A. Ivaska, M. Bochenska, and A. Lewenstam Solid-contact ion-selective electrodes with highly selective thioamide derivatives of p-tert-butylcalixarene for the determination of lead(II) in environmental samples Anal. Chem. 85 2013 1555
    • (2013) Anal. Chem. , vol.85 , pp. 1555
    • Guzinski, M.1    Lisak, G.2    Sokalski, T.3    Bobacka, J.4    Ivaska, A.5    Bochenska, M.6    Lewenstam, A.7
  • 12
    • 0002862870 scopus 로고
    • A study of the behaviour of solid-state membrane electrodes: Part III. A model for the response time
    • J. Buffle, and N. Parthasarathy A study of the behaviour of solid-state membrane electrodes: Part III. A model for the response time Anal. Chim. Acta 93 1977 111
    • (1977) Anal. Chim. Acta , vol.93 , pp. 111
    • Buffle, J.1    Parthasarathy, N.2
  • 14
    • 38249018249 scopus 로고
    • Surface characterization of lead ion selective electrodes: Life after adsorption
    • V. Young Surface characterization of lead ion selective electrodes: Life after adsorption J. Microchem. 42 1990 25
    • (1990) J. Microchem. , vol.42 , pp. 25
    • Young, V.1
  • 16
    • 77955708870 scopus 로고    scopus 로고
    • Comparison of different approaches to the description of the detection limit of ion-selective electrodes
    • J.J. Jasielec, T. Sokalski, R. Filipek, and A. Lewenstam Comparison of different approaches to the description of the detection limit of ion-selective electrodes Electrochim. Acta 55 2010 6836
    • (2010) Electrochim. Acta , vol.55 , pp. 6836
    • Jasielec, J.J.1    Sokalski, T.2    Filipek, R.3    Lewenstam, A.4
  • 17
    • 84872533315 scopus 로고    scopus 로고
    • Nernst-Planck-Poisson model for the description of behaviour of solid-contact ion-selective electrodes at low analyte concentration
    • J.J. Jasielec, G. Lisak, M. Wagner, T. Sokalski, and A. Lewenstam Nernst-Planck-Poisson model for the description of behaviour of solid-contact ion-selective electrodes at low analyte concentration Electroanal. 25 2013 133
    • (2013) Electroanal. , vol.25 , pp. 133
    • Jasielec, J.J.1    Lisak, G.2    Wagner, M.3    Sokalski, T.4    Lewenstam, A.5
  • 18
    • 84907983511 scopus 로고    scopus 로고
    • Directive 2006/118/EC 27.12.2006
    • Directive 2006/118/EC, Off. J. Eur. Union, 27.12.2006, 372, p.19.
    • Off. J. Eur. Union , vol.372 , pp. 19
  • 19
    • 0030694423 scopus 로고    scopus 로고
    • Large improvement of the lower detection limit of ion-selective polymer membrane electrodes
    • T. Sokalski, A. Ceresa, T. Zwickl, and E. Pretsch Large improvement of the lower detection limit of ion-selective polymer membrane electrodes J. Am. Chem. Soc. 119 1997 11347
    • (1997) J. Am. Chem. Soc. , vol.119 , pp. 11347
    • Sokalski, T.1    Ceresa, A.2    Zwickl, T.3    Pretsch, E.4
  • 20
    • 77749334566 scopus 로고    scopus 로고
    • Ion-selective electrodes with sensitivity in strongly diluted solutions
    • K.N. Mikhelson Ion-selective electrodes with sensitivity in strongly diluted solutions J. Anal. Chem. 65 2010 112
    • (2010) J. Anal. Chem. , vol.65 , pp. 112
    • Mikhelson, K.N.1
  • 21
    • 7644224476 scopus 로고    scopus 로고
    • Factors affecting the potentiometric response of all-solid-state solvent polymeric membrane calcium-selective electrode for low-level measurements
    • A. Konopka, T. Sokalski, A. Michalska, A. Lewenstam, and M. Maj-Zurawska Factors affecting the potentiometric response of all-solid-state solvent polymeric membrane calcium-selective electrode for low-level measurements Anal. Chem. 76 2004 6410
    • (2004) Anal. Chem. , vol.76 , pp. 6410
    • Konopka, A.1    Sokalski, T.2    Michalska, A.3    Lewenstam, A.4    Maj-Zurawska, M.5
  • 22
    • 15444379268 scopus 로고    scopus 로고
    • Thick membrane, solid contact ion selective electrode for the detection of lead at picomolar levels, Anal
    • M. Fouskaki, and N.A. Chaniotakis Thick membrane, solid contact ion selective electrode for the detection of lead at picomolar levels, Anal Chem. 77 2005 1780
    • (2005) Chem. , vol.77 , pp. 1780
    • Fouskaki, M.1    Chaniotakis, N.A.2
  • 28
    • 84865492073 scopus 로고    scopus 로고
    • Recovery of nanomolar detection limit of solid-contact lead (II)-selective electrodes by electrode conditioning
    • G. Lisak, J. Bobacka, and A. Lewenstam Recovery of nanomolar detection limit of solid-contact lead (II)-selective electrodes by electrode conditioning J. Solid State Electr. 16 2012 2983
    • (2012) J. Solid State Electr. , vol.16 , pp. 2983
    • Lisak, G.1    Bobacka, J.2    Lewenstam, A.3
  • 29
    • 33746611667 scopus 로고    scopus 로고
    • Approaches to Improving the lower detection limit of polymeric membrane ion-selective electrodes
    • Z. Szigeti, T. Vigassy, E. Bakker, and E. Pretsch Approaches to Improving the lower detection limit of polymeric membrane ion-selective electrodes Electroanal. 18 2006 1254
    • (2006) Electroanal. , vol.18 , pp. 1254
    • Szigeti, Z.1    Vigassy, T.2    Bakker, E.3    Pretsch, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.