메뉴 건너뛰기




Volumn 137, Issue 2, 2015, Pages

Modeling and experimental characterization of pressure drop in gravity-driven microfluidic systems

Author keywords

analytical; gravity driven; microfluidic; modeling; passive pump

Indexed keywords

MODELS;

EID: 84907938524     PISSN: 00982202     EISSN: 1528901X     Source Type: Journal    
DOI: 10.1115/1.4028501     Document Type: Article
Times cited : (23)

References (28)
  • 1
    • 77952499476 scopus 로고    scopus 로고
    • Fundamentals of microfluidic cell culture in controlled microenvironments
    • Young, E. W. K., and Beebe, D. J., 2010, "Fundamentals of Microfluidic Cell Culture in Controlled Microenvironments," Chem. Soc. Rev., 39(3), pp. 1036-1048.
    • (2010) Chem. Soc. Rev. , vol.39 , Issue.3 , pp. 1036-1048
    • Young, E.W.K.1    Beebe, D.J.2
  • 2
    • 35549011879 scopus 로고    scopus 로고
    • Flow rate analysis of a surface tension driven passive micropump
    • Berthier, E., and Beebe, D. J., 2007, "Flow Rate Analysis of a Surface Tension Driven Passive Micropump," Lab Chip, 7(11), pp. 1475-1478.
    • (2007) Lab Chip , vol.7 , Issue.11 , pp. 1475-1478
    • Berthier, E.1    Beebe, D.J.2
  • 3
    • 77951893943 scopus 로고    scopus 로고
    • An automated microdroplet passive pumping platform for high-speed and packeted microfluidic flow applications
    • Resto, P. J., Mogen, B. J., Berthier, E., and Williams, J. C., 2010, "An Automated Microdroplet Passive Pumping Platform for High-Speed and Packeted Microfluidic Flow Applications," Lab Chip, 10(1), pp. 23-26.
    • (2010) Lab Chip , vol.10 , Issue.1 , pp. 23-26
    • Resto, P.J.1    Mogen, B.J.2    Berthier, E.3    Williams, J.C.4
  • 4
    • 79960963700 scopus 로고    scopus 로고
    • Integrated Microfluidic Array Plate (iMAP) for cellular and molecular analysis
    • Dimov, I. K., Kijanka, G., Park, Y., Ducr-ee, J., Kang, T., and Lee, L. P., 2011, "Integrated Microfluidic Array Plate (iMAP) for Cellular and Molecular Analysis," Lab Chip, 11(16), pp. 2701-2710.
    • (2011) Lab Chip , vol.11 , Issue.16 , pp. 2701-2710
    • Dimov, I.K.1    Kijanka, G.2    Park, Y.3    Ducree, J.4    Kang, T.5    Lee, L.P.6
  • 5
    • 79955405131 scopus 로고    scopus 로고
    • A pumpless cell culture chip with the constant medium perfusion-rate maintained by balanced droplet dispensing
    • Kim, T., and Cho, Y.-H., 2011, "A Pumpless Cell Culture Chip With the Constant Medium Perfusion-Rate Maintained by Balanced Droplet Dispensing," Lab Chip, 11(10), pp. 1825-1830.
    • (2011) Lab Chip , vol.11 , Issue.10 , pp. 1825-1830
    • Kim, T.1    Cho, Y.-H.2
  • 6
    • 84867125779 scopus 로고    scopus 로고
    • On-Chip three-dimensional tumor spheroid formation and pump-less perfusion culture using gravity-driven cell aggregation and balanced droplet dispensing
    • Kim, T., Doh, I., and Cho, Y.-H., 2012, "On-Chip Three-Dimensional Tumor Spheroid Formation and Pump-Less Perfusion Culture Using Gravity-Driven Cell Aggregation and Balanced Droplet Dispensing," Biomicrofluidics, 6(3), p. 034107.
    • (2012) Biomicrofluidics , vol.6 , Issue.3 , pp. 034107
    • Kim, T.1    Doh, I.2    Cho, Y.-H.3
  • 7
    • 75749153235 scopus 로고    scopus 로고
    • A microfluidic device for a pharmacokinetic-pharmacodynamic (PK-PD) model on a chip
    • Sung, J. H., Kam, C., and Shuler, M. L., 2010, "A Microfluidic Device for a Pharmacokinetic-Pharmacodynamic (PK-PD) Model on a Chip," Lab Chip, 10(4), pp. 446-455.
    • (2010) Lab Chip , vol.10 , Issue.4 , pp. 446-455
    • Sung, J.H.1    Kam, C.2    Shuler, M.L.3
  • 8
    • 8844266899 scopus 로고    scopus 로고
    • Arrays of horizontally oriented mini-reservoirs generate steady microfluidic flows for continuous perfusion cell culture and gradient generation
    • Zhu, X., Chu, L. Y., Chueh, B.-H., Shen, M., Hazarika, B., Phadke, N., and Takayama, S., 2004, "Arrays of Horizontally Oriented Mini-Reservoirs Generate Steady Microfluidic Flows for Continuous Perfusion Cell Culture and Gradient Generation," Analyst, 129(11), pp. 1026-1031.
    • (2004) Analyst , vol.129 , Issue.11 , pp. 1026-1031
    • Zhu, X.1    Chu, L.Y.2    Chueh, B.-H.3    Shen, M.4    Hazarika, B.5    Phadke, N.6    Takayama, S.7
  • 9
    • 84860885527 scopus 로고    scopus 로고
    • A compact microfluidic gradient generator using passive pumping
    • Gao, Y., Sun, J., Lin, W.-H., Webb, D. J., and Li, D., 2012, "A Compact Microfluidic Gradient Generator Using Passive Pumping," Microfluid. Nanofluid., 12(6), pp. 887-895.
    • (2012) Microfluid. Nanofluid. , vol.12 , Issue.6 , pp. 887-895
    • Gao, Y.1    Sun, J.2    Lin, W.-H.3    Webb, D.J.4    Li, D.5
  • 10
    • 80053914815 scopus 로고    scopus 로고
    • Microfluidic array for three-dimensional perfusion culture of human mammary epithelial cells
    • Chen, S.-Y. C., Hung, P. J., and Lee, P. J., 2011, "Microfluidic Array for Three-Dimensional Perfusion Culture of Human Mammary Epithelial Cells," Biomed. Microdevices, 13(4), pp. 753-758.
    • (2011) Biomed. Microdevices , vol.13 , Issue.4 , pp. 753-758
    • Chen, S.-Y.C.1    Hung, P.J.2    Lee, P.J.3
  • 11
    • 52649136688 scopus 로고    scopus 로고
    • Modular microfluidics for gradient generation
    • Sun, K., Wang, Z., and Jiang, X., 2008, "Modular Microfluidics for Gradient Generation," Lab Chip, 8(9), pp. 1536-1543.
    • (2008) Lab Chip , vol.8 , Issue.9 , pp. 1536-1543
    • Sun, K.1    Wang, Z.2    Jiang, X.3
  • 12
    • 33750149392 scopus 로고    scopus 로고
    • Microfluidic circuits with tunable flow resistances
    • Lam, E. W., Cooksey, G. A., Finlayson, B. A., and Folch, A., 2006, "Microfluidic Circuits With Tunable Flow Resistances," Appl. Phys. Lett., 89(16), p. 164105.
    • (2006) Appl. Phys. Lett. , vol.89 , Issue.16 , pp. 164105
    • Lam, E.W.1    Cooksey, G.A.2    Finlayson, B.A.3    Folch, A.4
  • 13
    • 79959882441 scopus 로고    scopus 로고
    • System-level simulation of liquid filling in microfluidic chips
    • Song, H., Wang, Y., and Pant, K., 2011, "System-Level Simulation of Liquid Filling in Microfluidic Chips," Biomicrofluidics, 5(2), p. 024107.
    • (2011) Biomicrofluidics , vol.5 , Issue.2 , pp. 024107
    • Song, H.1    Wang, Y.2    Pant, K.3
  • 14
    • 84862908073 scopus 로고    scopus 로고
    • Design of pressure-driven microfluidic networks using electric circuit analogy
    • Oh, K. W., Lee, K., Ahn, B., and Furlani, E. P., 2012, "Design of Pressure-Driven Microfluidic Networks Using Electric Circuit Analogy," Lab Chip, 12(3), pp. 515-545.
    • (2012) Lab Chip , vol.12 , Issue.3 , pp. 515-545
    • Oh, K.W.1    Lee, K.2    Ahn, B.3    Furlani, E.P.4
  • 16
    • 79959325995 scopus 로고    scopus 로고
    • Manifold design for micro-channel cooling with uniform flow distribution
    • Solovitz, S. A., and Mainka, J., 2011, "Manifold Design for Micro-Channel Cooling With Uniform Flow Distribution," ASME J. Fluids Eng., 133(5), p. 051103.
    • (2011) ASME J. Fluids Eng. , vol.133 , Issue.5 , pp. 051103
    • Solovitz, S.A.1    Mainka, J.2
  • 17
    • 84857774176 scopus 로고    scopus 로고
    • Incompressible laminar developing flow in microchannels
    • Galvis, E., Yarusevych, S., and Culham, J. R., 2012, "Incompressible Laminar Developing Flow in Microchannels," ASME J. Fluids Eng., 134(1), p. 014503.
    • (2012) ASME J. Fluids Eng. , vol.134 , Issue.1 , pp. 014503
    • Galvis, E.1    Yarusevych, S.2    Culham, J.R.3
  • 18
    • 35548998936 scopus 로고    scopus 로고
    • Oxford University Press Inc., New York
    • Bruus, H., 2008, Theoretical Microfluidics, Oxford University Press Inc., New York.
    • (2008) Theoretical Microfluidics
    • Bruus, H.1
  • 20
    • 79959309669 scopus 로고    scopus 로고
    • Modeling and simulation of capillary microfluidic networks based on electrical analogies
    • Kang, S.-W., and Banerjee, D., 2011, "Modeling and Simulation of Capillary Microfluidic Networks Based on Electrical Analogies," ASME J. Fluids Eng., 133(5), p. 054502.
    • (2011) ASME J. Fluids Eng. , vol.133 , Issue.5 , pp. 054502
    • Kang, S.-W.1    Banerjee, D.2
  • 21
    • 0032403465 scopus 로고    scopus 로고
    • Rapid prototyping of microfluidic systems in poly(Dimethylsiloxane)
    • Duffy, D. C., McDonald, J. C., Schueller, O. J. A., and Whitesides, G. M., 1998, "Rapid Prototyping of Microfluidic Systems in Poly(Dimethylsiloxane)," Anal. Chem., 70(23), pp. 4974-4984.
    • (1998) Anal. Chem. , vol.70 , Issue.23 , pp. 4974-4984
    • Duffy, D.C.1    McDonald, J.C.2    Schueller, O.J.A.3    Whitesides, G.M.4
  • 22
    • 79953032082 scopus 로고    scopus 로고
    • Fluid flow in trapezoidal silicon microchannels with 3D Random rough bottoms
    • Xiong, R., 2011, "Fluid Flow in Trapezoidal Silicon Microchannels With 3D Random Rough Bottoms," ASME J. Fluids Eng., 133(3), p. 031102.
    • (2011) ASME J. Fluids Eng. , vol.133 , Issue.3 , pp. 031102
    • Xiong, R.1
  • 23
    • 76349115022 scopus 로고    scopus 로고
    • Pressure drop in rectangular microchannels as compared with theory based on arbitrary cross section
    • Akbari, M., Sinton, D., and Bahrami, M., 2009, "Pressure Drop in Rectangular Microchannels as Compared With Theory Based on Arbitrary Cross Section," ASME J. Fluids Eng., 131(4), p. 041202.
    • (2009) ASME J. Fluids Eng. , vol.131 , Issue.4 , pp. 041202
    • Akbari, M.1    Sinton, D.2    Bahrami, M.3
  • 24
    • 72849132951 scopus 로고    scopus 로고
    • Passive microfluidic pumping using coupled capillary/evaporation effects
    • Lynn, N. S., and Dandy, D. S., 2009, "Passive Microfluidic Pumping Using Coupled Capillary/Evaporation Effects," Lab Chip, 9(23), pp. 3422-3429.
    • (2009) Lab Chip , vol.9 , Issue.23 , pp. 3422-3429
    • Lynn, N.S.1    Dandy, D.S.2
  • 25
    • 77957338127 scopus 로고    scopus 로고
    • Finite reservoir effect on capillary flow of microbead suspension in rectangular microchannels
    • Waghmare, P. R., and Mitra, S. K., 2010, "Finite Reservoir Effect on Capillary Flow of Microbead Suspension in Rectangular Microchannels," J. Colloid Interface Sci., 351(2), pp. 561-569.
    • (2010) J. Colloid Interface Sci. , vol.351 , Issue.2 , pp. 561-569
    • Waghmare, P.R.1    Mitra, S.K.2
  • 26
    • 84856228694 scopus 로고    scopus 로고
    • A comprehensive theoretical model of capillary transport in rectangular microchannels
    • Waghmare, P. R., and Mitra, S. K., 2012, "A Comprehensive Theoretical Model of Capillary Transport in Rectangular Microchannels," Microfluid. Nanofluid., 12(1-4), pp. 53-63.
    • (2012) Microfluid. Nanofluid. , vol.12 , Issue.1-4 , pp. 53-63
    • Waghmare, P.R.1    Mitra, S.K.2
  • 27
    • 77957851663 scopus 로고    scopus 로고
    • Modeling and analysis of bump effect on capillary flow through microchannels
    • Chen, C.-C., 2010, "Modeling and Analysis of Bump Effect on Capillary Flow Through Microchannels," Int. Commun. Heat Mass Transfer, 37(9), pp. 1321-1325.
    • (2010) Int. Commun. Heat Mass Transfer , vol.37 , Issue.9 , pp. 1321-1325
    • Chen, C.-C.1
  • 28
    • 79960905844 scopus 로고    scopus 로고
    • Capillary-driven multiparametric microfluidic chips for one-step immunoassays
    • Gervais, L., Hitzbleck, M., and Delamarche, E., 2011, "Capillary-Driven Multiparametric Microfluidic Chips for One-Step Immunoassays," Biosens. Bioelectron., 27(1), pp. 64-70.
    • (2011) Biosens. Bioelectron. , vol.27 , Issue.1 , pp. 64-70
    • Gervais, L.1    Hitzbleck, M.2    Delamarche, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.