메뉴 건너뛰기




Volumn , Issue , 2014, Pages

Application of a new method in detecting a mechanical failure associated with series capacitance change in a power transformer winding

Author keywords

Frequency Response Analysis; mechanical failure; transformer winding; Winding series capacitance

Indexed keywords

CAPACITANCE; DIELECTRIC LIQUIDS; ELECTRIC TRANSFORMER TESTING; FREQUENCY RESPONSE; POWER TRANSFORMERS; TRANSFORMER WINDINGS; WINDING;

EID: 84907901724     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICDL.2014.6893098     Document Type: Conference Paper
Times cited : (3)

References (9)
  • 1
    • 84864644410 scopus 로고    scopus 로고
    • Mechanical-condition assessment of transformer windings using FRA
    • CIGRE Report 342 WG A2. 26, "Mechanical-condition assessment of transformer windings using FRA", 2008.
    • (2008) GRE Report 342 WG A2 , vol.26
  • 5
    • 80054078087 scopus 로고    scopus 로고
    • Estimation of series capacitance of a transformer winding based on Frequency-Response data: An indirect measurement approach
    • S. Pramanik and L. Satish, "Estimation of series capacitance of a transformer winding based on Frequency-Response data: An indirect measurement approach", IEEE Trans. on Power Delivery, Vol. 26, No. 4, pp. 2870-2878, 2011.
    • (2011) IEEE Trans. on Power Delivery , vol.26 , Issue.4 , pp. 2870-2878
    • Pramanik, S.1    Satish, L.2
  • 6
    • 84885663546 scopus 로고    scopus 로고
    • Estimation of series capacitance for a threephase transformer winding from its measured frequency response
    • S. Pramanik and L. Satish, "Estimation of series capacitance for a threephase transformer winding from its measured frequency response", IEEE Trans. on Power Delivery, Vol. 28, No. 4, p. 2437-2444, 2013.
    • (2013) IEEE Trans. on Power Delivery , vol.28 , Issue.4 , pp. 2437-2444
    • Pramanik, S.1    Satish, L.2
  • 7
    • 84896299091 scopus 로고    scopus 로고
    • A new method for purposes of failure diagnostics and FRA interpretation applicable to power transformers
    • OAK. Pham, T.M.T. Pham, H. Borsi and E. Gockenbach, "A new method for purposes of failure diagnostics and FRA interpretation applicable to power transformers", IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 20, No. 6, pp. 2026-2034, 2013.
    • (2013) IEEE Trans. on Dielectrics and Electrical Insulation , vol.20 , Issue.6 , pp. 2026-2034
    • Pham, O.A.K.1    Pham, T.M.T.2    Borsi, H.3    Gockenbach, E.4
  • 8
    • 0031257413 scopus 로고    scopus 로고
    • Influence of single-phase excitation and magnetizing reactance on transformer leakage reactance measurement
    • M.F. Laclnnan, and YN Shafir, "Influence of single-phase excitation and magnetizing reactance on transformer leakage reactance measurement", IEEE Trans. on Power Delivery, Vol. 12, No. 4, pp. 1538-1546, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.4 , pp. 1538-1546
    • Laclnnan, M.F.1    Shafir, Y.N.2
  • 9
    • 84866162949 scopus 로고    scopus 로고
    • A methodology for obtaining by measurements the transformer physical-circuital model parameters
    • ISSN, R. 88 NR 9a
    • Guillermo Aponte, Hector Cadavid, Juan Carlos Burgos and Eduardo Gomez, "A methodology for obtaining by measurements the transformer physical-circuital model parameters", Przeg"td Elektrotechniczny (Electrical Review), ISSN 0033-2097, R. 88 NR 9a, 2012.
    • (2012) Przegląd Elektrotechniczny (Electrical Review) , pp. 0033-2097
    • Aponte, G.1    Cadavid, H.2    Carlos Burgos, J.3    Gomez, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.