-
1
-
-
84907864738
-
Myocardial lesion size after epicardial electroporation catheter ablation after subxiphoid puncture
-
Neven K, van Driel V, van Wessel H, van Es R, Doevendans PA, Wittkampf F. Myocardial lesion size after epicardial electroporation catheter ablation after subxiphoid puncture. Circ Arrhythm Electrophysiol. 2014;7:728-733.
-
(2014)
Circ Arrhythm Electrophysiol
, vol.7
, pp. 728-733
-
-
Neven, K.1
Van Driel, V.2
Van Wessel, H.3
Van Es, R.4
Doevendans, P.A.5
Wittkampf, F.6
-
2
-
-
84907882177
-
Pulmonary vein stenosis after catheter ablation: Electroporation versus radiofrequency
-
van Driel VJ, Neven KG, van Wessel H, du Pre BC, Vink A, Doevendans PA, Wittkampf FH. Pulmonary vein stenosis after catheter ablation: Electroporation versus radiofrequency. Circ Arrhythm Electrophysiol. 2014;7:734-738.
-
(2014)
Circ Arrhythm Electrophysiol
, vol.7
, pp. 734-738
-
-
Van Driel, V.J.1
Neven, K.G.2
Van Wessel, H.3
Du Pre, B.C.4
Vink, A.5
Doevendans, P.A.6
Wittkampf, F.H.7
-
3
-
-
0020039354
-
Catheter technique for closed-chest ablation of the atrioventricular conduction system
-
Gallagher JJ, Svenson RH, Kasell JH, German LD, Bardy GH, Broughton A, Critelli G. Catheter technique for closed-chest ablation of the atrioventricular conduction system. N Engl J Med. 1982;306:194-200.
-
(1982)
N Engl J Med
, vol.306
, pp. 194-200
-
-
Gallagher, J.J.1
Svenson, R.H.2
Kasell, J.H.3
German, L.D.4
Bardy, G.H.5
Broughton, A.6
Critelli, G.7
-
4
-
-
0023098126
-
Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy - A new method of catheter ablation
-
Huang SK, Bharati S, Graham AR, Lev M, Marcus FI, Odell RC. Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy-a new method of catheter ablation. J Am Coll Cardiol. 1987;9:349-358.
-
(1987)
J Am Coll Cardiol
, vol.9
, pp. 349-358
-
-
Huang, S.K.1
Bharati, S.2
Graham, A.R.3
Lev, M.4
Marcus, F.I.5
Odell, R.C.6
-
5
-
-
0025203969
-
Long-term follow-up of patients after transcatheter direct current ablation of the atrioventricular junction
-
Rosenquvist M, Lee MA, Moulinier L, Springer MJ, Abbott JA, Wu J, Langberg JJ, Griffin JC, Scheinman MM. Long-term follow-up of patients after transcatheter direct current ablation of the atrioventricular junction. J Am Coll Cardiol. 1990;16:1467-1474.
-
(1990)
J Am Coll Cardiol
, vol.16
, pp. 1467-1474
-
-
Rosenquvist, M.1
Lee, M.A.2
Moulinier, L.3
Springer, M.J.4
Abbott, J.A.5
Wu, J.6
Langberg, J.J.7
Griffin, J.C.8
Scheinman, M.M.9
-
6
-
-
0024119179
-
The percutaneous cardiac mapping and ablation registry: Final summary of results
-
Evans GT Jr, Scheinman MM, Zipes DP, Benditt D, Breithardt G, Camm AJ, el-Sherif N, Fisher J, Fontaine G, Levy S, Prystowsky E, Josephson M, Morady F, Ruskin. The percutaneous cardiac mapping and ablation registry: Final summary of results. Pacing Clin Electrophysiol. 1988;11:1621-1626.
-
(1988)
Pacing Clin Electrophysiol
, vol.11
, pp. 1621-1626
-
-
Evans, G.T.1
Scheinman, M.M.2
Zipes, D.P.3
Benditt, D.4
Breithardt, G.5
Camm, A.J.6
El-Sherif, N.7
Fisher, J.8
Fontaine, G.9
Levy, S.10
Prystowsky, E.11
Josephson, M.12
Morady, F.13
Ruskin14
-
7
-
-
0027396960
-
A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction
-
Morady F, Calkins H, Langberg JJ, Armstrong WF, de Buitleir M, el-Atassi R, Kalbfleisch SJ. A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction. J Am Coll Cardiol. 1993;21:102-109.
-
(1993)
J Am Coll Cardiol
, vol.21
, pp. 102-109
-
-
Morady, F.1
Calkins, H.2
Langberg, J.J.3
Armstrong, W.F.4
De Buitleir, M.5
El-Atassi, R.6
Kalbfleisch, S.J.7
-
8
-
-
0027450105
-
Comparison of high energy direct current and radiofrequency catheter ablation of the atrioventricular junction
-
Olgin JE, Scheinman MM. Comparison of high energy direct current and radiofrequency catheter ablation of the atrioventricular junction. J Am Coll Cardiol. 1993;21:557-564.
-
(1993)
J Am Coll Cardiol
, vol.21
, pp. 557-564
-
-
Olgin, J.E.1
Scheinman, M.M.2
-
9
-
-
17044380150
-
Tissue ablation with irreversible electroporation
-
Davalos RV, Mir IL, Rubinsky B. Tissue ablation with irreversible electroporation. Ann Biomed Eng. 2005;33:223-231.
-
(2005)
Ann Biomed Eng
, vol.33
, pp. 223-231
-
-
Davalos, R.V.1
Mir, I.L.2
Rubinsky, B.3
-
10
-
-
34247378671
-
A novel nonthermal energy source for surgical epicardial atrial ablation: Irreversible electroporation
-
Lavee J, Onik G, Mikus P, Rubinsky B. A novel nonthermal energy source for surgical epicardial atrial ablation: irreversible electroporation. Heart Surg Forum. 2007;10:E162-E167.
-
(2007)
Heart Surg Forum
, vol.10
, pp. E162-E167
-
-
Lavee, J.1
Onik, G.2
Mikus, P.3
Rubinsky, B.4
-
11
-
-
77956842629
-
Nonthermal irreversible electroporation for tissue decellularization
-
Phillips M, Maor E, Rubinsky B. Nonthermal irreversible electroporation for tissue decellularization. J Biomech Eng. 2010;132:091003.
-
(2010)
J Biomech Eng
, vol.132
, pp. 091003
-
-
Phillips, M.1
Maor, E.2
Rubinsky, B.3
-
12
-
-
0028361024
-
Theory of electroporation of planar bilayer membranes: Predictions of the aqueous area, change in capacitance, and pore-pore separation
-
Freeman SA, Wang MA, Weaver JC. Theory of electroporation of planar bilayer membranes: predictions of the aqueous area, change in capacitance, and pore-pore separation. Biophys J. 1994;67:42-56.
-
(1994)
Biophys J
, vol.67
, pp. 42-56
-
-
Freeman, S.A.1
Wang, M.A.2
Weaver, J.C.3
-
13
-
-
81355147083
-
High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contraction
-
Arena CB, Sano MB, Rossmeisl JH Jr, Caldwell JL, Garcia PA, Rylander MN, Davalos RV. High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contraction. Biomed Eng Online. 2011;10:102.
-
(2011)
Biomed Eng Online
, vol.10
, pp. 102
-
-
Arena, C.B.1
Sano, M.B.2
Rossmeisl, J.H.3
Caldwell, J.L.4
Garcia, P.A.5
Rylander, M.N.6
Davalos, R.V.7
-
14
-
-
84910599102
-
Novel balloon catheter device with pacing, ablating, electroporation, and drug eluting capabilities for atrial fibrillation treatment-preliminary efficacy and safety studies in a canine model
-
July 16, 2014
-
DeSimone CV, Ebrille E, Syed FF, Mikell SB, Suddendorf SH, Wahnschaffe D, Ladewig DJ, Gilles EJ, Danielsen AJ, Holmes DR Jr, Asirvatham SJ. Novel balloon catheter device with pacing, ablating, electroporation, and drug eluting capabilities for atrial fibrillation treatment-preliminary efficacy and safety studies in a canine model [published online ahead of print July 16, 2014]. Transl Res. http://www.sciencedirect.com/science/article/pii/S1931524414002400. doi: 10.1016/j.trsl.2014.07.002.
-
Transl Res
-
-
DeSimone, C.V.1
Ebrille, E.2
Syed, F.F.3
Mikell, S.B.4
Suddendorf, S.H.5
Wahnschaffe, D.6
Ladewig, D.J.7
Gilles, E.J.8
Danielsen, A.J.9
Holmes, D.R.10
Asirvatham, S.J.11
-
15
-
-
84894104031
-
Marked suppression of pulmonary vein firing after circumferential pulmonary vein isolation in patients with paroxysmal atrial fibrillation: Is pulmonary vein firing an epiphenomenon?
-
Jiang RH, Jiang CY, Sheng X, Zhang ZW, Sun YX, Liu Q, Fu GS, Po SS. Marked suppression of pulmonary vein firing after circumferential pulmonary vein isolation in patients with paroxysmal atrial fibrillation: Is pulmonary vein firing an epiphenomenon? J Cardiovasc Electrophysiol. 2014;25:111-118.
-
(2014)
J Cardiovasc Electrophysiol
, vol.25
, pp. 111-118
-
-
Jiang, R.H.1
Jiang, C.Y.2
Sheng, X.3
Zhang, Z.W.4
Sun, Y.X.5
Liu, Q.6
Fu, G.S.7
Po, S.S.8
-
16
-
-
33745464758
-
Autonomic innervation and segmental muscular disconnections at the human pulmonary vein-atrial junction: Implications for catheter ablation of atrial-pulmonary vein junction
-
Tan AY, Li H, Wachsmann-Hogiu S, Chen LS, Chen PS, Fishbein MC. Autonomic innervation and segmental muscular disconnections at the human pulmonary vein-atrial junction: implications for catheter ablation of atrial-pulmonary vein junction. J Am Coll Cardiol. 2006;48:132-143.
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 132-143
-
-
Tan, A.Y.1
Li, H.2
Wachsmann-Hogiu, S.3
Chen, L.S.4
Chen, P.S.5
Fishbein, M.C.6
-
17
-
-
77952143205
-
Epicardial ventricular tachycardia ablation a multicenter safety study
-
Sacher F, Roberts-Thomson K, Maury P, Tedrow U, Nault I, Steven D, Hocini M, Koplan B, Leroux L, Derval N, Seiler J, Wright MJ, Epstein L, Haissaguerre M, Jais P, Stevenson WG. Epicardial ventricular tachycardia ablation a multicenter safety study. J Am Coll Cardiol. 2010;55:2366-2372.
-
(2010)
J Am Coll Cardiol
, vol.55
, pp. 2366-2372
-
-
Sacher, F.1
Roberts-Thomson, K.2
Maury, P.3
Tedrow, U.4
Nault, I.5
Steven, D.6
Hocini, M.7
Koplan, B.8
Leroux, L.9
Derval, N.10
Seiler, J.11
Wright, M.J.12
Epstein, L.13
Haissaguerre, M.14
Jais, P.15
Stevenson, W.G.16
-
18
-
-
79958091355
-
Irreversible electroporation of the pancreas: Definitive local therapy without systemic effects
-
Bower M, Sherwood L, Li Y, Martin R. Irreversible electroporation of the pancreas: definitive local therapy without systemic effects. J Surg Oncol. 2011;104:22-28.
-
(2011)
J Surg Oncol
, vol.104
, pp. 22-28
-
-
Bower, M.1
Sherwood, L.2
Li, Y.3
Martin, R.4
-
19
-
-
84874485878
-
Irreversible electroporation: The new generation of local ablation techniques for renal cell carcinoma
-
Liehr UB, Wendler JJ, Blaschke S, Porsch M, Janitzky A, Baumunk D, Pech M, Fischbach F, Schindele D, Grube C, Ricke J, Schostak M. Irreversible electroporation: the new generation of local ablation techniques for renal cell carcinoma. Urologe A. 2012;51:1728-1734.
-
(2012)
Urologe A
, vol.51
, pp. 1728-1734
-
-
Liehr, U.B.1
Wendler, J.J.2
Blaschke, S.3
Porsch, M.4
Janitzky, A.5
Baumunk, D.6
Pech, M.7
Fischbach, F.8
Schindele, D.9
Grube, C.10
Ricke, J.11
Schostak, M.12
|