메뉴 건너뛰기




Volumn 9, Issue 3, 2014, Pages 449-452

Instructive head-mounted display system: Pointing device using a vision-based finger tracking technique applied to surgical education

Author keywords

Data display; Endoscopes; Teaching

Indexed keywords

ARTICLE; BLADDER SURGERY; CAMERA; CLINICAL EDUCATION; DISPLAY SYSTEM; ENDOSCOPY; HUMAN; IMAGING SOFTWARE; INDEX FINGER; INTERPERSONAL COMMUNICATION; MEDICAL STUDENT; SURGICAL TRAINING; VISION BASED FINGER TRACKING SYSTEM;

EID: 84907736868     PISSN: 18954588     EISSN: 22990054     Source Type: Journal    
DOI: 10.5114/wiitm.2014.44132     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 9644284441 scopus 로고    scopus 로고
    • Robotic surgery in urology: Fact or fantasy?
    • Binder J, Bräutigam R, Jonas D, Bentas W. Robotic surgery in urology: fact or fantasy? BJU Int 2004; 94: 1183-7.
    • (2004) BJU Int , vol.94 , pp. 1183-1187
    • Binder, J.1    Bräutigam, R.2    Jonas, D.3    Bentas, W.4
  • 2
    • 84884949411 scopus 로고    scopus 로고
    • Robot-assisted right colectomy: Surgical technique and review of the literature
    • Witkiewicz W, Zawadzki M, Rząca M, et al. Robot-assisted right colectomy: surgical technique and review of the literature. Videosurgery Miniinv 2013; 8: 253-7.
    • (2013) Videosurgery Miniinv , vol.8 , pp. 253-257
    • Witkiewicz, W.1    Zawadzki, M.2    Rząca, M.3
  • 3
    • 84880493827 scopus 로고    scopus 로고
    • Robotic surgery-A taste of Hollywood?
    • Czudek S. Robotic surgery-A taste of Hollywood? Videosurgery Miniinv 2013; 8: 95-8.
    • (2013) Videosurgery Miniinv , vol.8 , pp. 95-98
    • Czudek, S.1
  • 4
    • 77950980531 scopus 로고    scopus 로고
    • Monitoring with head-mounted displays in general anesthesia: A clinical evaluation in the operating room
    • Liu D, Jenkins SA, Sanderson PM, et al. Monitoring with head-mounted displays in general anesthesia: a clinical evaluation in the operating room. Anesth Analg 2010; 110: 1032-8.
    • (2010) Anesth Analg , vol.110 , pp. 1032-1038
    • Liu, D.1    Jenkins, S.A.2    Sanderson, P.M.3
  • 5
    • 70349570134 scopus 로고    scopus 로고
    • Monitoring with head-mounted displays: Performance and safety in a full-scale simulator and part-task trainer
    • Liu D, Jenkins SA, Sanderson PM, et al. Monitoring with head-mounted displays: performance and safety in a full-scale simulator and part-task trainer. Anesth Analg 2009; 109: 1135-46.
    • (2009) Anesth Analg , vol.109 , pp. 1135-1146
    • Liu, D.1    Jenkins, S.A.2    Sanderson, P.M.3
  • 6
    • 65349187556 scopus 로고    scopus 로고
    • Surgical performance with head-mounted displays in laparoscopic surgery
    • Prendergast CJ, Ryder BA, Abodeely A, et al. Surgical performance with head-mounted displays in laparoscopic surgery. J Laparoendosc Adv Surg Tech A 2009; 19 Suppl. 1: S237-40.
    • (2009) J Laparoendosc Adv Surg Tech A , vol.19 , pp. S237-S240
    • Prendergast, C.J.1    Ryder, B.A.2    Abodeely, A.3
  • 7
    • 84865551702 scopus 로고    scopus 로고
    • New three-dimensional head-mounted display system, TMDU-S-3D system, for minimally invasive surgery application: Procedures for gasless single-port radical nephrectomy
    • Kihara K, Fujii Y, Masuda H, et al. New three-dimensional head-mounted display system, TMDU-S-3D system, for minimally invasive surgery application: procedures for gasless single-port radical nephrectomy. Int J Urol 2012; 19: 886-9.
    • (2012) Int J Urol , vol.19 , pp. 886-889
    • Kihara, K.1    Fujii, Y.2    Masuda, H.3
  • 8
    • 84907752867 scopus 로고    scopus 로고
    • A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate
    • in press
    • Yoshida S, Kihara K, Takeshita H, Fujii Y. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate. Videosurgery Miniinv in press.
    • Videosurgery Miniinv
    • Yoshida, S.1    Kihara, K.2    Takeshita, H.3    Fujii, Y.4
  • 9
    • 84923603819 scopus 로고    scopus 로고
    • Head-mounted display for personal integrated-image monitoring system: Ureteral stent placement
    • in press
    • Yoshida S, Kihara K, Takeshita H, et al. Head-mounted display for personal integrated-image monitoring system: ureteral stent placement. Urol Int in press.
    • Urol Int
    • Yoshida, S.1    Kihara, K.2    Takeshita, H.3
  • 10
    • 84905750099 scopus 로고    scopus 로고
    • Clinical application of a modern high-definition head-mounted display in sonography
    • Takeshita H, Kihara K, Yoshida S, et al. Clinical application of a modern high-definition head-mounted display in sonography. J Ultrasound Med 2014; 33: 1499-504.
    • (2014) J Ultrasound Med , vol.33 , pp. 1499-1504
    • Takeshita, H.1    Kihara, K.2    Yoshida, S.3
  • 11
    • 84855226636 scopus 로고    scopus 로고
    • High-precision, three-dimensional tracking of mouse whisker movements with optical motion capture technology
    • Roy S, Bryant JL, Cao Y, Heck DH. High-precision, three-dimensional tracking of mouse whisker movements with optical motion capture technology. Front Behav Neurosci 2011; 5: 27.
    • (2011) Front Behav Neurosci , vol.5 , pp. 27
    • Roy, S.1    Bryant, J.L.2    Cao, Y.3    Heck, D.H.4
  • 12
    • 77954682295 scopus 로고    scopus 로고
    • A new method for motion capture of the scapula using an optoelectronic tracking device: A feasibility study
    • Šenk M, Chèze L. A new method for motion capture of the scapula using an optoelectronic tracking device: a feasibility study. Comput Methods Biomech Biomed Engin 2010; 13: 397-401.
    • (2010) Comput Methods Biomech Biomed Engin , vol.13 , pp. 397-401
    • Šenk, M.1    Chèze, L.2
  • 13
    • 67650248232 scopus 로고    scopus 로고
    • Nearly automatic motion capture system for tracking octopus arm movements in 3D space
    • Zelman I, Galun M, Akselrod-Ballin A, et al. Nearly automatic motion capture system for tracking octopus arm movements in 3D space. J Neurosci Methods 2009; 182: 97-109.
    • (2009) J Neurosci Methods , vol.182 , pp. 97-109
    • Zelman, I.1    Galun, M.2    Akselrod-Ballin, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.