메뉴 건너뛰기




Volumn 9, Issue 9, 2014, Pages

Liquid- and air-filled catheters without balloon as an alternative to the air-filled balloon catheter for measurement of esophageal pressure

Author keywords

[No Author keywords available]

Indexed keywords

AIR FILLED CATHETER; ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; ARTIFICIAL VENTILATION; BALLOON CATHETER; BREATHING MECHANICS; CATHETER; CONTROLLED STUDY; DEVICE COMPARISON; END EXPIRATORY VALUE OF TRANSPULMONARY PRESSURE; ESOPHAGEAL PRESSURE TIME PRODUCT; ESOPHAGUS PRESSURE; FEMALE; INSPIRATORY CHANGE IN TRANSPULMONARY PRESSURE; INSPIRATORY WORK OF BREATHING; LIQUID FILLED CATHETER; LUNG AND CHEST WALL ELASTANCE; NONHUMAN; OUTCOME ASSESSMENT; POSITIVE END EXPIRATORY PRESSURE; PRESSURE MEASUREMENT; RESPIRATORY TRACT PARAMETERS; AIR; ANIMAL; CATHETERIZATION; COMPARATIVE STUDY; DEVICES; ESOPHAGUS; HUMAN; PHYSIOLOGIC MONITORING; PHYSIOLOGY; PIG; PLEURA; PRESSURE; PROCEDURES; SIGNAL NOISE RATIO;

EID: 84907587775     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0103057     Document Type: Article
Times cited : (14)

References (30)
  • 1
    • 56249128276 scopus 로고    scopus 로고
    • Mechanical ventilation guided by esophageal pressure in acute lung injury
    • Talmor D, Sarge T, Malhotra A, O'Donnell CR, Ritz R, et al. (2008) Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 359: 2095-2104.
    • (2008) N Engl J Med , vol.359 , pp. 2095-2104
    • Talmor, D.1    Sarge, T.2    Malhotra, A.3    O'donnell, C.R.4    Ritz, R.5
  • 2
    • 17444429629 scopus 로고    scopus 로고
    • Esophageal and gastric pressure measurements
    • Benditt JO (2005) Esophageal and gastric pressure measurements. Respir Care 50: 68-75.
    • (2005) Respir Care , vol.50 , pp. 68-75
    • Benditt, J.O.1
  • 3
    • 0031695119 scopus 로고    scopus 로고
    • Monitoring patient mechanics during mechanical ventilation
    • Jubran A (1998) Monitoring patient mechanics during mechanical ventilation. Crit Care Clin 14: 629-53.
    • (1998) Crit Care Clin , vol.14 , pp. 629-653
    • Jubran, A.1
  • 5
    • 84876830414 scopus 로고    scopus 로고
    • Esophageal pressure mesurement
    • Hamid Q, Joanne Shannon MD, Martin JG, editors. BC Decker, Incorporated
    • Zin WA, Milic-Emili J (2005) Esophageal Pressure Mesurement. In: Hamid Q, Joanne Shannon MD, Martin JG, editors. Physiologic Basis of Respiratory Disease. BC Decker, Incorporated. pp. 639-647.
    • (2005) Physiologic Basis of Respiratory Disease , pp. 639-647
    • Zin, W.A.1    Milic-Emili, J.2
  • 6
    • 33644485934 scopus 로고
    • Improved technique for estimating pleural pressure from esophageal balloons
    • Milic-Emili J, Mead J, Turner JM, Glauser EM (1964) Improved technique for estimating pleural pressure from esophageal balloons. J Appl Physiol 19: 207-211.
    • (1964) J Appl Physiol , vol.19 , pp. 207-211
    • Milic-Emili, J.1    Mead, J.2    Turner, J.M.3    Glauser, E.M.4
  • 8
    • 0020592728 scopus 로고
    • Measurement of pleural pressure with esophageal balloon in anesthetized humans
    • Higgs BD, Behrakis PK, Bevan DR, Milic-Emili J (1983) Measurement of pleural pressure with esophageal balloon in anesthetized humans. Anesthesiology 59: 340-343.
    • (1983) Anesthesiology , vol.59 , pp. 340-343
    • Higgs, B.D.1    Behrakis, P.K.2    Bevan, D.R.3    Milic-Emili, J.4
  • 10
    • 70449250383 scopus 로고
    • Esophageal and pleural pressures in man, upright and supine
    • Mead J, Gaensler EA (1959) Esophageal and pleural pressures in man, upright and supine. J Appl Physiol 14: 81-83.
    • (1959) J Appl Physiol , vol.14 , pp. 81-83
    • Mead, J.1    Gaensler, E.A.2
  • 11
    • 0035402479 scopus 로고    scopus 로고
    • Recruitment and derecruitment during acute respiratory failure: An experimental study
    • Pelosi P, Goldner M, McKibben A, Adams A, Eccher G, et al. (2001) Recruitment and derecruitment during acute respiratory failure: an experimental study. Am J Respir Crit Care Med 164: 122-130.
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 122-130
    • Pelosi, P.1    Goldner, M.2    McKibben, A.3    Adams, A.4    Eccher, G.5
  • 12
    • 0038443410 scopus 로고    scopus 로고
    • Novel aspects of pulmonary mechanics in intensive care
    • De Chazal I, Hubmayr RD (2003) Novel aspects of pulmonary mechanics in intensive care. Br J Anaesth 91: 81-91.
    • (2003) Br J Anaesth , vol.91 , pp. 81-91
    • De Chazal, I.1    Hubmayr, R.D.2
  • 13
    • 0021262949 scopus 로고
    • How alterations in pleural pressure influence esophageal pressure
    • Hurewitz AN, Sidhu U, Bergofsky EH, Chanana AD (1984) How alterations in pleural pressure influence esophageal pressure. J Appl Physiol 56: 1162-1169.
    • (1984) J Appl Physiol , vol.56 , pp. 1162-1169
    • Hurewitz, A.N.1    Sidhu, U.2    Bergofsky, E.H.3    Chanana, A.D.4
  • 14
    • 0026575459 scopus 로고
    • Factors affecting the accuracy of esophageal balloon measurement of pleural pressure in dogs
    • Dechman G, Sato J, Bates JHT (1992) Factors affecting the accuracy of esophageal balloon measurement of pleural pressure in dogs. J Appl Physiol 72: 383-388.
    • (1992) J Appl Physiol , vol.72 , pp. 383-388
    • Dechman, G.1    Sato, J.2    Bates, J.H.T.3
  • 15
    • 56249124625 scopus 로고    scopus 로고
    • PEEP guided by esophageal pressure - Any added value?
    • Bernard GR (2008) PEEP Guided by Esophageal Pressure - Any Added Value? N Engl J Med 359: 2166-2168.
    • (2008) N Engl J Med , vol.359 , pp. 2166-2168
    • Bernard, G.R.1
  • 16
    • 0023177841 scopus 로고
    • Validation of esophageal balloon technique at different lung volumes and postures
    • Baydur A, Cha EJ, Sassoon CS (1987) Validation of esophageal balloon technique at different lung volumes and postures. J Appl Physiol 62: 315-321.
    • (1987) J Appl Physiol , vol.62 , pp. 315-321
    • Baydur, A.1    Cha, E.J.2    Sassoon, C.S.3
  • 17
    • 84908144695 scopus 로고
    • The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms
    • Welch P (1967) The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. Audio Electroacoust IEEE Trans 15: 70-73.
    • (1967) Audio Electroacoust IEEE Trans , vol.15 , pp. 70-73
    • Welch, P.1
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327: 307-310.
    • (1986) Lancet , vol.327 , pp. 307-310
    • Bland, J.M.1    Altman, D.2
  • 19
    • 0024443890 scopus 로고
    • Liquid-filled esophageal catheter for measuring pleural pressure in preterm neonates
    • Coates AL, Davis GM, Vallinis P, Outerbridge EW (1989) Liquid-filled esophageal catheter for measuring pleural pressure in preterm neonates. J Appl Physiol 67: 889-893.
    • (1989) J Appl Physiol , vol.67 , pp. 889-893
    • Coates, A.L.1    Davis, G.M.2    Vallinis, P.3    Outerbridge, E.W.4
  • 20
    • 0017514486 scopus 로고
    • Choosing a catheter system for measuring intra-oesophageal pressure
    • Maxted KJ, Shaw A, Macdonald TH (1977) Choosing a catheter system for measuring intra-oesophageal pressure. Med Biol Eng Comput 15: 398-401.
    • (1977) Med Biol Eng Comput , vol.15 , pp. 398-401
    • Maxted, K.J.1    Shaw, A.2    Macdonald, T.H.3
  • 21
    • 0032979237 scopus 로고    scopus 로고
    • A simplified method for separate measurements of lung and chest wall mechanics in ventilator-treated patients
    • Karason S, Karlsen KL, Lundin S, Stenqvist O (1999) A simplified method for separate measurements of lung and chest wall mechanics in ventilator-treated patients. Acta Anaesthesiol Scand 43: 308-315.
    • (1999) Acta Anaesthesiol Scand , vol.43 , pp. 308-315
    • Karason, S.1    Karlsen, K.L.2    Lundin, S.3    Stenqvist, O.4
  • 23
    • 0026575456 scopus 로고
    • Comparison of balloon and transducer catheters for estimating lung elasticity
    • Panizza JA, Finucane KE (1992) Comparison of balloon and transducer catheters for estimating lung elasticity. J Appl Physiol 72: 231-235.
    • (1992) J Appl Physiol , vol.72 , pp. 231-235
    • Panizza, J.A.1    Finucane, K.E.2
  • 24
    • 0020504736 scopus 로고
    • Inaccuracy of oesophageal pressure for pleural pressure estimation in supine anaesthetized subjects
    • Drummond GB, Wright ADG (1983) Inaccuracy of oesophageal pressure for pleural pressure estimation in supine anaesthetized subjects. Br J Anaesth 55: 585-593.
    • (1983) Br J Anaesth , vol.55 , pp. 585-593
    • Drummond, G.B.1    Wright, A.D.G.2
  • 25
    • 77949628652 scopus 로고    scopus 로고
    • Is there a place for esophageal manometry in the care of patients with injured lungs?
    • Hubmayr RD (2010) Is there a place for esophageal manometry in the care of patients with injured lungs? J Appl Physiol 108: 481-482.
    • (2010) J Appl Physiol , vol.108 , pp. 481-482
    • Hubmayr, R.D.1
  • 26
    • 0034744382 scopus 로고    scopus 로고
    • Removal of cardiac beat artifact in esophageal pressure measurement via a modified adaptive noise cancellation scheme
    • Cheng Y-PP, Wu H-DD, Jan G-JJ, Wang C-YY (2001) Removal of cardiac beat artifact in esophageal pressure measurement via a modified adaptive noise cancellation scheme. Ann Biomed Eng 29: 236-243.
    • (2001) Ann Biomed Eng , vol.29 , pp. 236-243
    • Cheng, Y.-P.P.1    Wu, H.-D.D.2    Jan, G.-J.J.3    Wang, C.-Y.Y.4
  • 28
    • 33645801991 scopus 로고    scopus 로고
    • Volume-related and volumeindependent effects of posture on esophageal and transpulmonary pressures in healthy subjects
    • Washko GR, O'Donnell CR, Loring SH (2006) Volume-related and volumeindependent effects of posture on esophageal and transpulmonary pressures in healthy subjects. J Appl Physiol 100: 753-758.
    • (2006) J Appl Physiol , vol.100 , pp. 753-758
    • Washko, G.R.1    O'donnell, C.R.2    Loring, S.H.3
  • 29
    • 0000056474 scopus 로고
    • Effect of body position on esophageal pressure and measurement of pulmonary compliance
    • Ferris BG, Mead J, Frank NR (1959) Effect of body position on esophageal pressure and measurement of pulmonary compliance. J Appl Physiol 14: 521-524.
    • (1959) J Appl Physiol , vol.14 , pp. 521-524
    • Ferris, B.G.1    Mead, J.2    Frank, N.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.