메뉴 건너뛰기




Volumn 84, Issue , 2014, Pages 360-366

Energy-saving potential of a novel ventilation system with decentralised fans in an office building

Author keywords

Decentralised fans; Low energy demand; Low pressure drop; Mechanical ventilation

Indexed keywords

DROPS; ENERGY CONSERVATION; ENERGY MANAGEMENT; OFFICE BUILDINGS; PRESSURE DROP; SYSTEMS ANALYSIS;

EID: 84907553952     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2014.08.029     Document Type: Article
Times cited : (21)

References (25)
  • 7
    • 78651446488 scopus 로고    scopus 로고
    • Analytical and experimental analysis of a low-pressure heat exchanger suitable for passive ventilation
    • C.A. Hviid, and S. Svendsen Analytical and experimental analysis of a low-pressure heat exchanger suitable for passive ventilation Energy and Buildings 43 2011 275 284
    • (2011) Energy and Buildings , vol.43 , pp. 275-284
    • Hviid, C.A.1    Svendsen, S.2
  • 8
    • 0033662060 scopus 로고    scopus 로고
    • Super-efficient mechanical ventilation
    • J. Berry Super-efficient mechanical ventilation Indoor and Built Environment 9 2000 87 96
    • (2000) Indoor and Built Environment , vol.9 , pp. 87-96
    • Berry, J.1
  • 9
    • 84907499917 scopus 로고    scopus 로고
    • Energy recovery possibilities in natural ventilation of office buildings
    • OSCAR FABER PLC United Kingdom
    • E. Skaret, P. Blom, and J. Brunsell Energy recovery possibilities in natural ventilation of office buildings Document-Air Infiltration Centre AIC PROC vol. 2 1997 OSCAR FABER PLC United Kingdom 311 322
    • (1997) Document-Air Infiltration Centre AIC PROC , vol.2 , pp. 311-322
    • Skaret, E.1    Blom, P.2    Brunsell, J.3
  • 12
    • 0029277022 scopus 로고
    • Air-handling energy efficiency and design practices
    • L.J. Nilsson Air-handling energy efficiency and design practices Energy and Buildings 22 1995 1 13
    • (1995) Energy and Buildings , vol.22 , pp. 1-13
    • Nilsson, L.J.1
  • 14
    • 0038518217 scopus 로고    scopus 로고
    • Demand controlled ventilation for office cubicles - Can it be profitable?
    • M. Mysen, J. Rydock, and P. Tjelflaat Demand controlled ventilation for office cubicles - can it be profitable? Energy and Buildings 35 2003 657 662
    • (2003) Energy and Buildings , vol.35 , pp. 657-662
    • Mysen, M.1    Rydock, J.2    Tjelflaat, P.3
  • 15
    • 40349116620 scopus 로고    scopus 로고
    • Ventilation strategies for good indoor air quality and energy efficiency
    • O. Seppänen Ventilation strategies for good indoor air quality and energy efficiency International Journal of Ventilation 6 2008 297 306
    • (2008) International Journal of Ventilation , vol.6 , pp. 297-306
    • Seppänen, O.1
  • 16
    • 77956172174 scopus 로고    scopus 로고
    • Energy efficient demand controlled ventilation in single family houses
    • T.R. Nielsen, and C. Drivsholm Energy efficient demand controlled ventilation in single family houses Energy and Buildings 42 2010 1995 1998
    • (2010) Energy and Buildings , vol.42 , pp. 1995-1998
    • Nielsen, T.R.1    Drivsholm, C.2
  • 18
    • 84907497721 scopus 로고    scopus 로고
    • Improved motor technology for small fans - Impact of efficiency gains on system design
    • FINVAC Helsinki, Finland
    • A. Karlsson, and C. Markusson Improved motor technology for small fans - impact of efficiency gains on system design Proceedings of Clima 2007 WellBeing Indoors 2007 FINVAC Helsinki, Finland
    • (2007) Proceedings of Clima 2007 WellBeing Indoors
    • Karlsson, A.1    Markusson, C.2
  • 24
    • 84907497717 scopus 로고    scopus 로고
    • Heating and Air Conditioning Technology, Ventilation Technology 1st ed. Danvak Denmark
    • O.B. Stampe Varme-og klimateknik, ventilationsteknik Heating and Air Conditioning Technology, Ventilation Technology 1st ed. 2000 Danvak Denmark
    • (2000) Varme-og Klimateknik, Ventilationsteknik
    • Stampe, O.B.1