메뉴 건너뛰기




Volumn 84, Issue , 2014, Pages 548-556

CO2 sensors for occupancy estimations: Potential in building automation applications

Author keywords

Building automation system; Controller robustness; Heating ventilation and air conditioning; Indoor air quality; Information deficiencies; Model predictive control; Occupancy estimations; Office buildings; Predictive control

Indexed keywords

OFFICE BUILDINGS;

EID: 84907541445     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2014.09.002     Document Type: Article
Times cited : (64)

References (19)
  • 4
    • 78651445032 scopus 로고    scopus 로고
    • Model predictive control of a building heating system: The first experience
    • S. Prívara, J. Siroký, L. Ferkl, and J. Cigler Model predictive control of a building heating system: the first experience Energy and Buildings 43 3 2010 564 572
    • (2010) Energy and Buildings , vol.43 , Issue.3 , pp. 564-572
    • Prívara, S.1    Siroký, J.2    Ferkl, L.3    Cigler, J.4
  • 5
    • 79955483400 scopus 로고    scopus 로고
    • Experimental analysis of model predictive control for an energy efficient building heating system
    • J. Siroky, F. Oldewurtel, J. Cigler, and S. Privara Experimental analysis of model predictive control for an energy efficient building heating system Applied Energy 88 9 2011 3079 3087
    • (2011) Applied Energy , vol.88 , Issue.9 , pp. 3079-3087
    • Siroky, J.1    Oldewurtel, F.2    Cigler, J.3    Privara, S.4
  • 6
    • 84869885122 scopus 로고    scopus 로고
    • Importance of occupancy information for building climate control
    • F. Oldewurtel, D. Sturzenegger, and M. Morari Importance of occupancy information for building climate control Applied Energy 101 0 2013 521 532
    • (2013) Applied Energy , vol.101 , Issue.0 , pp. 521-532
    • Oldewurtel, F.1    Sturzenegger, D.2    Morari, M.3
  • 7
    • 84874421687 scopus 로고    scopus 로고
    • Occupancy-based zone-climate control for energy-efficient buildings: Complexity vs. Performance
    • S. Goyal, H.A. Ingley, and P. Barooah Occupancy-based zone-climate control for energy-efficient buildings: complexity vs. performance Applied Energy 106 0 2013 209 221
    • (2013) Applied Energy , vol.106 , Issue.0 , pp. 209-221
    • Goyal, S.1    Ingley, H.A.2    Barooah, P.3
  • 8
    • 84886462584 scopus 로고    scopus 로고
    • Model-based controllers for indoor climate control in office buildings - Complexity and performance evaluation
    • M. Gruber, A. Trüschel, and J.-O. Dalenbäck Model-based controllers for indoor climate control in office buildings - complexity and performance evaluation Energy and Buildings 68 Part A 2013 213 222
    • (2013) Energy and Buildings , vol.68 , Issue.PART A , pp. 213-222
    • Gruber, M.1    Trüschel, A.2    Dalenbäck, J.-O.3
  • 10
    • 77957760757 scopus 로고    scopus 로고
    • An integrated approach to occupancy modeling and estimation in commercial buildings
    • Marriott Waterfront, Baltimore, MD, USA
    • C. Liao, and P. Barooah An integrated approach to occupancy modeling and estimation in commercial buildings 2010 American Control Conference Marriott Waterfront, Baltimore, MD, USA 2010 3130 3135
    • (2010) 2010 American Control Conference , pp. 3130-3135
    • Liao, C.1    Barooah, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.